Brand: Future Design ControlsThe L22, L62 & L42 are FM approved limit controller that can be configured either as a high limit or as a low limit controller by the user.
These limit controllers are powered by an 11-26 or 90-250 VDC / VAC supply, incorporating a 2 Amp relay output as a standard.
The second output can be used as an alarm. Both outputs can be selected as a 5VDC or 14VDC logic output to drive an external device.
The limit controllers can be incorporated with two event inputs, up to 3 alarm outputs, RS-485 communication, retransmission voltage or current output optionally.
The limit controllers are fully programmable for linear current, linear voltage, Pt100 and thermocouple types J, K, T, E, B, R, S, N, L, U, P, C, and D.
The input signal is digitized by using an 18-bit A to D converter. Its fast-sampling rate allows the limit controller to protect fast processes.
Features- LCD Display
- High Accuracy 18 Bit A-D Conversion
- and 15 Bit D-A Conversion
- Fastest Sampling Rate of 200 msec
- Universal Input
- Up to 2 Event Inputs
- Remote Reset
- Remote Lock
- RS-485 Communication
- Lockout Protection
- Bidirectional Menu Navigation
- On-field Calibration
- °C / °F Temperature Measurements
- DIN Rail Mount Option
- Configurable Display Logic -SAFE
Specifications
Brand
Power Supply
- 90 to 250VA
- 47 to63Hz
- 20 to 28 VAC
- 47-63Hz / 11 to 40 VDC
Power Consumption
- L22: 8VA, 4W maximum
- L62: 10VA, 5W maximum
- L42: 12VA, 6W maximum
Over Voltage Category
- II
Signal Input Type
- Thermocouple (J, K, T, E, B, R, S, N, L, U, P, C, D)
- RTD(Pt100(DIN)
- Pt100(JIS)
- Current(mA)
- Voltage (V, mV)
Signal Input Resolution
- 18 Bits
Signal Input Sampling Rate
- 5 Times / Second
- 200msec
Signal Input Maximum Rating
- -2VDC minimum,
- 12VDC maximum
Signal Input - Input Characteristics (Type: Range, Accuracy @ 25°C, Input Impedance)
- J: -120°C to 1000°C ( -184°F to 1832°F), ±2°C, 2.2 MΩ
- K: -200°C to 1370°C (-328°F to 2498°F), ±2°C, 2.2 MΩ
- T: -250°C to 400°C ( -418°F to 752°F), ±2°C, 2.2 MΩ
- E: -100°C to 900°C ( -148°F to 1652°F), ±2°C, 2.2 MΩ
- B: 0°C to 1820°C (32°F to 3308°F), ±2°C (200°C to 1800°C), 2.2 MΩ
- R: 0°C to 1767.8°C (32°F to 3214°F), ±2°C, 2.2 MΩ
- S: 0°C to 1767.8°C (32°F to 3214°F), ±2°C, 2.2 MΩ
- N: -250°C to 1300°C ( -418°F to 2372°F), ±2°C, 2.2 MΩ
- L: -200°C to 900°C ( -328°F to 1652°F), ±2°C, 2.2 MΩ
- U: -200°C to 600°C (-328°F to 1112°F), ±2°C, 2.2 MΩ
- P: 0°C to 1395°C (32°F to 2543°F), ±2°C, 2.2 MΩ
- C: 0°C to 2300°C (32°F to 4172°F), ±2°C, 2.2 MΩ
- D: 0°C to 2300°C (32°F to 4172°F), ±2°C, 2.2 MΩ
- Pt100(DIN): -210°C to 700°C ( -346°F to 1292°F), ±0.4°C, 1.3KΩ
- Pt100(JIS): -200°C to 600°C ( -328°F to 1112°F), ±0.4°C, 1.3KΩ
- mA: -3mA to 27mA, ±0.05%, 2.5Ω
- VDC: -1.3VDC to 11.5VDC, ±0.05%, 1.5MΩ
- mV: 0 to 50mV, ±0.05%, 2.2 MΩ
Signal Input Temperature Effect
- 1.5μV /°C for all inputs except mA input
- 3.0μV /°C for mA
Signal Input Sensor Lead Resistance Effect
- Thermocouple: 0.2 μV / Ω; 3-wire RTD: 2.6°C /Ω of difference of resistance of two leads
- 2-wire RTD: 2.6°C /Ω of sum of resistance of two leads
Signal Input Burn-out Current
- 200 nA
Signal Input CMRR
- 120 dB
Signal Input NMRR
- 55 dB
Signal Input Sensor Break Detection
- Sensor open for Thermocouple
- RTD and mV inputs
- Sensor short for RTD input
- Below 1mA for 4-20mA input
- Below 0.25VDC for 1 - 5VDC input
- Not available for other inputs.
Signal Input Sensor Break Response Time
- Within 4 seconds for Thermocouple,
- RTD and mV inputs
- 0.1 second for 4-20mA and 1 - 5VDC inputs
Digital Filter Function
- First Order
Digital Filter Time Constant
- 0,0.2, 0.5, 1, 2, 5, 10, 20, 30, 60 Seconds
- Programmable
Number of Event Inputs
- L22: 1
- L62: 2
- L42: 3
Event Input Logic Low
- -10VDC minimum
- 0.8VDC maximum
Event Input Logic High
- 2VDC minimum
- 10VDC maximum
Event Input Functions
- Remote lock
- Remote reset output1
- HSP2
- LSP2
- HLS2
- HSP3
- LSP3
- HLS3
- Reset alarm1
- Reset alarm2
- Reset alarm3
- Reset all alarms
- Cancel latch
- Reset reference data
Output 1 /Output 2 Limit Control Function
- High Limit
- Low Limit and High / Low Limit
Output 1 /Output 2 Type
- Relay
- Pulsed Voltage
Output 1 /Output 2 Relay Type
- Form A
Output 1 /Output 2 Relay Rating
- 2A
- 240V AC
- 200000 Life cycles for resistive load
Output 1 /Output 2 Pulsed Voltage
- Source voltage 5VDC
- Current limiting resistance 66Ω
Output 1 /Output 2 Temperature Effect
- ±0.01% of Span/ °C
Alarm Relay Type
- Form A
Alarm Maximum Rating
- 2A
- 240VAC
- 200000 Life cycles for resistive load
Alarm Alarm Functions
- Process High
- Process Low
Alarm Alarm Mode
- Latching
- Normal
- Latching reverse
- Normal reverse
Data Communication Interface
- RS-485
Data Communication Protocol
- Modbus RTU (Slave mode)
Data Communication Address
- 1 to 247
Data Communication Baud Rate
- 2.8KBPS to 115.2KBPS
Data Communication Parity Bit
- None
- Even or Odd
Data Communication Stop Bit
- 1 or 2 Bits
Data Communication Data Length
- 7 or 8 Bits
Communication Buffer
- 160 Bytes
Analog Retransmission Output Signal
- 4-20mA
- 0-20 mA
- 0 - 10VDC
Analog Retransmission Resolution
- 15 Bits
Analog Retransmission Accuracy
- ±0.05% of Span ± 0.0025% / °C
Analog Retransmission Load Resistance
- 0 to 500Ω for current output
- 10KΩ minimum for voltage output
Analog Retransmission Output Regulation
- 0.01% for full load change
Analog Retransmission Output Setting Time
- 0.1Second (stable to 99.9%)
Analog Retransmission Isolation Breakdown
- 1000VAC min
Analog Retransmission Integral Linearity Error
- ±0.005% of span
Analog Retransmission Temperature Effect
- ±0.0025% of span /°C
Analog Retransmission Saturation Low
- 0mA or 0VDC
Analog Retransmission Saturation High
- 22.2mA or 5.55V,11.1V min
Analog Retransmission Linear Output Ranges
- 0-22.2mA (0-20mA/4-20mA)
- -5.55VDC (0-5VDC, 1-5VDC)
- -11.1VDC (0 - 10VDC)
User Interface Keypad
- 4 Keys
User Interface Display Type
- 4 Digit LCD display
User Interface Number of Display
- 2
User Interface Upper Display Size
- L22: 0.31” (8mm)
- L62: 0.58” (15mm)
- L42: 0.98” (25mm)
User Interface Lower Display Size
- L22: 0.25” (6.5mm)
- L62: 0.3” (7.8mm)
- L42: 0.55” (14mm)
Programming Port Interface
- Micro USB
Programming Port PC Communication Function
- Firmware upgrade
Operating Temperature
- -10°C to 50°C
Storage Temperature
- -40°C to 60°C
Humidity
- 0 to 90 % RH (Non-Condensing)
Altitude
- 2000 Meters maximum
Pollution
- Degree II
Insulation Resistance
- 20MΩ minimum (@500V DC)
Dielectric Strength
- 2000VAC
- 50/60 Hz for 1 minute
Vibration Resistance
- 10 to 55 Hz
- 10m/s2 for 2 hours
Shock Resistance
- 200 m/s2(20g)
Housing
- Flame retardant polycarbonate
Mounting
- L22: DIN-Rail
- L62: Panel
- L42: Panel
Size
- L62: 1/16
- L42: 1/4
Dimensions
- L22: 22.5 x 96 x 83mm
- L62: 48 x 48 x 59mm
- L42: 96 x 96 x 59mm
Depth Behind Panel
- L62: 50mm
- L42: 50mm
Cut Out Dimensions
- L62: 45 x 45mm
- L42: 92 x 92mm
Weight
- L22: 160 grams
- L62: 160 grams
- L42: 290 grams
Safety
- FM Class 3545
- UL/cUL 61010-1 Category QUYX/QUYX7
- ROHS
- REACH
Protective Class
- IP50 for the front panel
- IP20 for rear terminals and housing
- All indoor use
EMC
- EN61326