Yodify Product Library
Add the Safety Barriers with Electronic Current Limitation Series 9004 to yourĀ store or catalogĀ Ā
Book Your Demo and See How
or create your store
Safety Barriers with Electronic Current Limitation Series 9004
Brand: R. STAHL AGR. STAHL's 9004 series INTRINSPAK single-channel safety barriers are ideally suited to supplying field devices with intrinsically safe auxiliary power due to their electronic current limitation.
They have a particularly good power yield and are available in many variants for circuits with a negative or positive potential, including for unregulated power supplies.
Features- For supplying field devices with intrinsically safe auxiliary power, variants for many applications
- flexible, space-saving devices that are easy to install on a DIN rail
- reduced storage due to standardized back-up fuse
1 - 12 of 13 Part Numbers
159060
For supplying field devices with intrinsically safe auxiliary power, variants for many applications
flexible, space-saving devices that are easy to install on a DIN rail
reduced storage due to standardised back-up fuse
Ambient Conditions
- Ambient temperature - -20 °C ... +60 °C
- Ambient temperature max. - +60 °C
- Ambient temperature min. - -20 °C
- Relative humidity max. - 95% on average, no condensation
- Storage temperature - -20 °C ... +75 °C
- Storage temperature max. - +75 °C
- Storage temperature min. - -20 °C
- Temperature influence - ≤ 0,25 %/10K
Auxiliary power
- Nominal voltage - 12.00 V
- Power supply - Controlled, nominal voltage
Electrical Data
- Max. resistance R max - 30.00 Ω
- Maximum output current I max - 40 mA
- Min. resistance R min - 26.00 Ω
- Number of channels - 1
- Potential - positive potential
- Rated operational voltage DC - 12.00 V
- Transmission frequency in case of electrical current limiting - ≤ 10 kHz
Explosion Protection
- Application range (zones) - 2, 22
- ATEX dust certificate - PTB 01 ATEX 2088 X
- ATEX gas certificate - PTB 02 ATEX 2008
- Certificates - ATEX (PTB), Canada (CSA), IECEx (PTB)
- Dust explosion protection ATEX - II (2) D [Ex ib Db] IIIC
- Dust explosion protection IECEx - [Ex ib Db] IIIC
- Ex interface zone - 1, 2, 21, 22
- Further information - see respective certificate and operating instructions
- Gas explosion protection ATEX - II 3 (2) G Ex nA [ib Gb] IIB/IIC T4 Gc
- Gas explosion protection IECEx - Ex nA [ib Gb] IIB/IIC T4 Gc
- IECEX dust certificate - IECEx PTB 09.0001X
- IECEX gas certificate - IECEx PTB 12.0003X
- Installation - in Zone 2, Division 2 and in safe area
General
- Functional Description - R. STAHL's 9004 series INTRINSPAK single-channel safety barriers are ideally suited to supplying field devices with intrinsically safe auxiliary power due to their electronic current limitation. They have a particularly good power yield and are available in many variants for circuits with a negative or positive potential, including for unregulated power supplies.
- Highlights - For supplying field devices with intrinsically safe auxiliary power, variants for many applications flexible, space-saving devices that are easy to install on a DIN rail reduced storage due to standardised back-up fuse
- Particularly suitable for - Exi power supply, solenoid valves
- Product Description - Single-channel safety barriers With electronic current limiting
- Product Type - 9004/01-168-050-001
- Product Variant - Series 9004/01, for positive potential
- Title Product Variant Technical Data - 9004/01-168-050-001 safety barrier
- WebCode - 9004A
Mechanical Data
- Clamping range max. - 1.50 mm²
- Connection cross-section - 4.0 mm²
- Degree of protection (IP) - IP40
- Enclosure material - Polyamide 6GF
- Length - 12.000 mm
- Mounting depth - 72.000 mm
- Number of connection terminals - 4
- Terminal degree of protection (IP) - IP20
- Type of connection cable - Finely stranded, solid
- Weight - 0.116 kg
- Width - 103.000 mm
Mounting / Installation
- Connection type - 2 PA
Safety Data
- Max. Current I o - 50.0 mA
- Max. permissible external capacitance C o for IIB - 1.200 μF
- Max. permissible external capacitance C o for IIC - 0.160 μF
- Max. permissible external inductance L o for IIB - 2.500 mH
- Max. permissible external inductance L o for IIC - 0.860 mH
- Max. Power P o - 840.000 mW
- Max. Voltage U o - 16.80 V
159064
For supplying field devices with intrinsically safe auxiliary power, variants for many applications
flexible, space-saving devices that are easy to install on a DIN rail
reduced storage due to standardised back-up fuse
Ambient Conditions
- Ambient temperature - -20 °C ... +60 °C
- Ambient temperature max. - +60 °C
- Ambient temperature min. - -20 °C
- Relative humidity max. - 95% on average, no condensation
- Storage temperature - -20 °C ... +75 °C
- Storage temperature max. - +75 °C
- Storage temperature min. - -20 °C
- Temperature influence - ≤ 0,25 %/10K
Auxiliary power
- Nominal voltage - 12.00 V
- Power supply - Controlled, nominal voltage
Electrical Data
- Max. resistance R max - 24.00 Ω
- Maximum output current I max - 80 mA
- Min. resistance R min - 20.00 Ω
- Number of channels - 1
- Potential - positive potential
- Rated operational voltage DC - 12.00 V
- Transmission frequency in case of electrical current limiting - ≤ 10 kHz
Explosion Protection
- Application range (zones) - 2, 22
- ATEX dust certificate - PTB 01 ATEX 2088 X
- ATEX gas certificate - PTB 02 ATEX 2008
- Certificates - ATEX (PTB), Canada (CSA), IECEx (PTB)
- Dust explosion protection ATEX - II (2) D [Ex ib Db] IIIC
- Dust explosion protection IECEx - [Ex ib Db] IIIC
- Ex interface zone - 1, 2, 21, 22
- Further information - see respective certificate and operating instructions
- Gas explosion protection ATEX - II 3 (2) G Ex nA [ib Gb] IIB/IIC T4 Gc
- Gas explosion protection IECEx - Ex nA [ib Gb] IIB/IIC T4 Gc
- IECEX dust certificate - IECEx PTB 09.0001X
- IECEX gas certificate - IECEx PTB 12.0003X
- Installation - in Zone 2, Division 2 and in safe area
General
- Functional Description - R. STAHL's 9004 series INTRINSPAK single-channel safety barriers are ideally suited to supplying field devices with intrinsically safe auxiliary power due to their electronic current limitation. They have a particularly good power yield and are available in many variants for circuits with a negative or positive potential, including for unregulated power supplies.
- Highlights - For supplying field devices with intrinsically safe auxiliary power, variants for many applications flexible, space-saving devices that are easy to install on a DIN rail reduced storage due to standardised back-up fuse
- Particularly suitable for - Exi power supply, solenoid valves
- Product Description - Single-channel safety barriers With electronic current limiting
- Product Type - 9004/01-168-100-001
- Product Variant - Series 9004/01, for positive potential
- Title Product Variant Technical Data - 9004/01-168-100-001 safety barrier
- WebCode - 9004A
Mechanical Data
- Clamping range max. - 1.50 mm²
- Connection cross-section - 4.0 mm²
- Degree of protection (IP) - IP40
- Enclosure material - Polyamide 6GF
- Length - 12.000 mm
- Mounting depth - 72.000 mm
- Number of connection terminals - 4
- Terminal degree of protection (IP) - IP20
- Type of connection cable - Finely stranded, solid
- Weight - 0.118 kg
- Width - 103.000 mm
Mounting / Installation
- Connection type - 2 PA
Safety Data
- Max. Current I o - 100.0 mA
- Max. permissible external capacitance C o for IIB - 1.100 μF
- Max. permissible external inductance L o for IIB - 1.600 mH
- Max. Power P o - 1680.000 mW
- Max. Voltage U o - 16.80 V
159068
For supplying field devices with intrinsically safe auxiliary power, variants for many applications
flexible, space-saving devices that are easy to install on a DIN rail
reduced storage due to standardised back-up fuse
Ambient Conditions
- Ambient temperature - -20 °C ... +60 °C
- Ambient temperature max. - +60 °C
- Ambient temperature min. - -20 °C
- Relative humidity max. - 95% on average, no condensation
- Storage temperature - -20 °C ... +75 °C
- Storage temperature max. - +75 °C
- Storage temperature min. - -20 °C
- Temperature influence - ≤ 0,25 %/10K
Auxiliary power
- Nominal voltage - 16.00 V
- Power supply - Controlled, nominal voltage
Electrical Data
- Max. resistance R max - 44.00 Ω
- Maximum output current I max - 40 mA
- Min. resistance R min - 34.00 Ω
- Number of channels - 1
- Potential - positive potential
- Rated operational voltage DC - 16.00 V
- Transmission frequency in case of electrical current limiting - ≤ 10 kHz
Explosion Protection
- Application range (zones) - 2, 22
- ATEX dust certificate - PTB 01 ATEX 2088 X
- ATEX gas certificate - PTB 02 ATEX 2008
- Certificates - ATEX (PTB), Canada (CSA), IECEx (PTB)
- Dust explosion protection ATEX - II (2) D [Ex ib Db] IIIC
- Dust explosion protection IECEx - [Ex ib Db] IIIC
- Ex interface zone - 1, 2, 21, 22
- Further information - see respective certificate and operating instructions
- Gas explosion protection ATEX - II 3 (2) G Ex nA [ib Gb] IIB/IIC T4 Gc
- Gas explosion protection IECEx - Ex nA [ib Gb] IIB/IIC T4 Gc
- IECEX dust certificate - IECEx PTB 09.0001X
- IECEX gas certificate - IECEx PTB 12.0003X
- Installation - in Zone 2, Division 2 and in safe area
General
- Functional Description - R. STAHL's 9004 series INTRINSPAK single-channel safety barriers are ideally suited to supplying field devices with intrinsically safe auxiliary power due to their electronic current limitation. They have a particularly good power yield and are available in many variants for circuits with a negative or positive potential, including for unregulated power supplies.
- Highlights - For supplying field devices with intrinsically safe auxiliary power, variants for many applications flexible, space-saving devices that are easy to install on a DIN rail reduced storage due to standardised back-up fuse
- Particularly suitable for - Exi power supply, solenoid valves
- Product Description - Single-channel safety barriers With electronic current limiting
- Product Type - 9004/01-200-050-001
- Product Variant - Series 9004/01, for positive potential
- Title Product Variant Technical Data - 9004/01-200-050-001 safety barrier
- WebCode - 9004A
Mechanical Data
- Clamping range max. - 1.50 mm²
- Connection cross-section - 4.0 mm²
- Degree of protection (IP) - IP40
- Enclosure material - Polyamide 6GF
- Length - 12.000 mm
- Mounting depth - 72.000 mm
- Number of connection terminals - 4
- Terminal degree of protection (IP) - IP20
- Type of connection cable - Finely stranded, solid
- Weight - 0.118 kg
- Width - 103.000 mm
Mounting / Installation
- Connection type - 2 PA
Safety Data
- Max. Current I o - 50.0 mA
- Max. permissible external capacitance C o for IIB - 0.680 μF
- Max. permissible external inductance L o for IIB - 2.500 mH
- Max. Power P o - 1000.000 mW
- Max. Voltage U o - 20.00 V
159076
For supplying field devices with intrinsically safe auxiliary power, variants for many applications
flexible, space-saving devices that are easy to install on a DIN rail
reduced storage due to standardised back-up fuse
Ambient Conditions
- Ambient temperature - -20 °C ... +60 °C
- Ambient temperature max. - +60 °C
- Ambient temperature min. - -20 °C
- Relative humidity max. - 95% on average, no condensation
- Storage temperature - -20 °C ... +75 °C
- Storage temperature max. - +75 °C
- Storage temperature min. - -20 °C
- Temperature influence - ≤ 0,25 %/10K
Auxiliary power
- Nominal voltage - 24.00 V
- Power supply - Controlled, nominal voltage
Electrical Data
- Max. resistance R max - 68.00 Ω
- Maximum output current I max - 20 mA
- Min. resistance R min - 60.00 Ω
- Number of channels - 1
- Potential - negative potential
- Rated operational voltage DC - 24.00 V
- Transmission frequency in case of electrical current limiting - ≤ 10 kHz
Explosion Protection
- Application range (zones) - 2, 22
- ATEX dust certificate - PTB 01 ATEX 2088 X
- ATEX gas certificate - PTB 02 ATEX 2008
- Certificates - ATEX (PTB), Canada (CSA), IECEx (PTB)
- Dust explosion protection ATEX - II (2) D [Ex ib Db] IIIC
- Dust explosion protection IECEx - [Ex ib Db] IIIC
- Ex interface zone - 1, 2, 21, 22
- Further information - see respective certificate and operating instructions
- Gas explosion protection ATEX - II 3 (2) G Ex nA [ib Gb] IIB/IIC T4 Gc
- Gas explosion protection IECEx - Ex nA [ib Gb] IIB/IIC T4 Gc
- IECEX dust certificate - IECEx PTB 09.0001X
- IECEX gas certificate - IECEx PTB 12.0003X
- Installation - in Zone 2, Division 2 and in safe area
General
- Functional Description - R. STAHL's 9004 series INTRINSPAK single-channel safety barriers are ideally suited to supplying field devices with intrinsically safe auxiliary power due to their electronic current limitation. They have a particularly good power yield and are available in many variants for circuits with a negative or positive potential, including for unregulated power supplies.
- Highlights - For supplying field devices with intrinsically safe auxiliary power, variants for many applications flexible, space-saving devices that are easy to install on a DIN rail reduced storage due to standardised back-up fuse
- Particularly suitable for - Exi power supply, solenoid valves
- Product Description - Single-channel safety barriers With electronic current limiting
- Product Type - 9004/00-280-025-001
- Product Variant - Series 9004/00, for negative potential
- Title Product Variant Technical Data - 9004/00-280-025-001 safety barrier
- WebCode - 9004A
Mechanical Data
- Clamping range max. - 1.50 mm²
- Connection cross-section - 4.0 mm²
- Degree of protection (IP) - IP40
- Enclosure material - Polyamide 6GF
- Length - 12.000 mm
- Mounting depth - 72.000 mm
- Number of connection terminals - 4
- Terminal degree of protection (IP) - IP20
- Type of connection cable - Finely stranded, solid
- Weight - 0.118 kg
- Width - 103.000 mm
Mounting / Installation
- Connection type - 2 PA
Safety Data
- Max. Current I o - 25.0 mA
- Max. permissible external capacitance C o for IIB - 0.280 μF
- Max. permissible external inductance L o for IIB - 2.500 mH
- Max. Power P o - 700.000 mW
- Max. Voltage U o - 28.00 V
159078
For supplying field devices with intrinsically safe auxiliary power, variants for many applications
flexible, space-saving devices that are easy to install on a DIN rail
reduced storage due to standardised back-up fuse
Ambient Conditions
- Ambient temperature - -20 °C ... +60 °C
- Ambient temperature max. - +60 °C
- Ambient temperature min. - -20 °C
- Relative humidity max. - 95% on average, no condensation
- Storage temperature - -20 °C ... +75 °C
- Storage temperature max. - +75 °C
- Storage temperature min. - -20 °C
- Temperature influence - ≤ 0,25 %/10K
Auxiliary power
- Nominal voltage - 24.00 V
- Power supply - Controlled, nominal voltage
Electrical Data
- Max. resistance R max - 68.00 Ω
- Maximum output current I max - 20 mA
- Min. resistance R min - 60.00 Ω
- Number of channels - 1
- Potential - positive potential
- Rated operational voltage DC - 24.00 V
- Transmission frequency in case of electrical current limiting - ≤ 10 kHz
Explosion Protection
- Application range (zones) - 2, 22
- ATEX dust certificate - PTB 01 ATEX 2088 X
- ATEX gas certificate - PTB 02 ATEX 2008
- Certificates - ATEX (PTB), Canada (CSA), IECEx (PTB)
- Dust explosion protection ATEX - II (2) D [Ex ib Db] IIIC
- Dust explosion protection IECEx - [Ex ib Db] IIIC
- Ex interface zone - 1, 2, 21, 22
- Further information - see respective certificate and operating instructions
- Gas explosion protection ATEX - II 3 (2) G Ex nA [ib Gb] IIB/IIC T4 Gc
- Gas explosion protection IECEx - Ex nA [ib Gb] IIB/IIC T4 Gc
- IECEX dust certificate - IECEx PTB 09.0001X
- IECEX gas certificate - IECEx PTB 12.0003X
- Installation - in Zone 2, Division 2 and in safe area
General
- Functional Description - R. STAHL's 9004 series INTRINSPAK single-channel safety barriers are ideally suited to supplying field devices with intrinsically safe auxiliary power due to their electronic current limitation. They have a particularly good power yield and are available in many variants for circuits with a negative or positive potential, including for unregulated power supplies.
- Highlights - For supplying field devices with intrinsically safe auxiliary power, variants for many applications flexible, space-saving devices that are easy to install on a DIN rail reduced storage due to standardised back-up fuse
- Particularly suitable for - Exi power supply, solenoid valves
- Product Description - Single-channel safety barriers With electronic current limiting
- Product Type - 9004/01-280-025-001
- Product Variant - Series 9004/01, for positive potential
- Title Product Variant Technical Data - 9004/01-280-025-001 safety barrier
- WebCode - 9004A
Mechanical Data
- Clamping range max. - 1.50 mm²
- Connection cross-section - 4.0 mm²
- Degree of protection (IP) - IP40
- Enclosure material - Polyamide 6GF
- Length - 12.000 mm
- Mounting depth - 72.000 mm
- Number of connection terminals - 4
- Terminal degree of protection (IP) - IP20
- Type of connection cable - Finely stranded, solid
- Weight - 0.116 kg
- Width - 103.000 mm
Mounting / Installation
- Connection type - 2 PA
Safety Data
- Max. Current I o - 25.0 mA
- Max. permissible external capacitance C o for IIB - 0.280 μF
- Max. permissible external inductance L o for IIB - 2.500 mH
- Max. Power P o - 700.000 mW
- Max. Voltage U o - 28.00 V
159080
For supplying field devices with intrinsically safe auxiliary power, variants for many applications
flexible, space-saving devices that are easy to install on a DIN rail
reduced storage due to standardised back-up fuse
Ambient Conditions
- Ambient temperature - -20 °C ... +60 °C
- Ambient temperature max. - +60 °C
- Ambient temperature min. - -20 °C
- Relative humidity max. - 95% on average, no condensation
- Storage temperature - -20 °C ... +75 °C
- Storage temperature max. - +75 °C
- Storage temperature min. - -20 °C
- Temperature influence - ≤ 0,25 %/10K
Auxiliary power
- Nominal voltage - 24.00 V
- Power supply - Controlled, nominal voltage
Electrical Data
- Max. resistance R max - 56.00 Ω
- Maximum output current I max - 35 mA
- Min. resistance R min - 50.00 Ω
- Number of channels - 1
- Potential - negative potential
- Rated operational voltage DC - 24.00 V
- Transmission frequency in case of electrical current limiting - ≤ 10 kHz
Explosion Protection
- Application range (zones) - 2, 22
- ATEX dust certificate - PTB 01 ATEX 2088 X
- ATEX gas certificate - PTB 02 ATEX 2008
- Certificates - ATEX (PTB), Canada (CSA), IECEx (PTB)
- Dust explosion protection ATEX - II (2) D [Ex ib Db] IIIC
- Dust explosion protection IECEx - [Ex ib Db] IIIC
- Ex interface zone - 1, 2, 21, 22
- Further information - see respective certificate and operating instructions
- Gas explosion protection ATEX - II 3 (2) G Ex nA [ib Gb] IIB/IIC T4 Gc
- Gas explosion protection IECEx - Ex nA [ib Gb] IIB/IIC T4 Gc
- IECEX dust certificate - IECEx PTB 09.0001X
- IECEX gas certificate - IECEx PTB 12.0003X
- Installation - in Zone 2, Division 2 and in safe area
General
- Functional Description - R. STAHL's 9004 series INTRINSPAK single-channel safety barriers are ideally suited to supplying field devices with intrinsically safe auxiliary power due to their electronic current limitation. They have a particularly good power yield and are available in many variants for circuits with a negative or positive potential, including for unregulated power supplies.
- Highlights - For supplying field devices with intrinsically safe auxiliary power, variants for many applications flexible, space-saving devices that are easy to install on a DIN rail reduced storage due to standardised back-up fuse
- Particularly suitable for - Exi power supply, solenoid valves
- Product Description - Single-channel safety barriers With electronic current limiting
- Product Type - 9004/00-280-045-001
- Product Variant - Series 9004/00, for negative potential
- Title Product Variant Technical Data - 9004/00-280-045-001 safety barrier
- WebCode - 9004A
Mechanical Data
- Clamping range max. - 1.50 mm²
- Connection cross-section - 4.0 mm²
- Degree of protection (IP) - IP40
- Enclosure material - Polyamide 6GF
- Length - 12.000 mm
- Mounting depth - 72.000 mm
- Number of connection terminals - 4
- Terminal degree of protection (IP) - IP20
- Type of connection cable - Finely stranded, solid
- Weight - 0.120 kg
- Width - 103.000 mm
Mounting / Installation
- Connection type - 2 PA
Safety Data
- Max. Current I o - 45.0 mA
- Max. permissible external capacitance C o for IIB - 0.280 μF
- Max. permissible external inductance L o for IIB - 1.500 mH
- Max. Power P o - 1260.000 mW
- Max. Voltage U o - 28.00 V
159082
For supplying field devices with intrinsically safe auxiliary power, variants for many applications
flexible, space-saving devices that are easy to install on a DIN rail
reduced storage due to standardised back-up fuse
Ambient Conditions
- Ambient temperature - -20 °C ... +60 °C
- Ambient temperature max. - +60 °C
- Ambient temperature min. - -20 °C
- Relative humidity max. - 95% on average, no condensation
- Storage temperature - -20 °C ... +75 °C
- Storage temperature max. - +75 °C
- Storage temperature min. - -20 °C
- Temperature influence - ≤ 0,25 %/10K
Auxiliary power
- Nominal voltage - 24.00 V
- Power supply - Controlled, nominal voltage
Electrical Data
- Max. resistance R max - 56.00 Ω
- Maximum output current I max - 35 mA
- Min. resistance R min - 50.00 Ω
- Number of channels - 1
- Potential - positive potential
- Rated operational voltage DC - 24.00 V
- Transmission frequency in case of electrical current limiting - ≤ 10 kHz
Explosion Protection
- Application range (zones) - 2, 22
- ATEX dust certificate - PTB 01 ATEX 2088 X
- ATEX gas certificate - PTB 02 ATEX 2008
- Certificates - ATEX (PTB), Canada (CSA), IECEx (PTB)
- Dust explosion protection ATEX - II (2) D [Ex ib Db] IIIC
- Dust explosion protection IECEx - [Ex ib Db] IIIC
- Ex interface zone - 1, 2, 21, 22
- Further information - see respective certificate and operating instructions
- Gas explosion protection ATEX - II 3 (2) G Ex nA [ib Gb] IIB/IIC T4 Gc
- Gas explosion protection IECEx - Ex nA [ib Gb] IIB/IIC T4 Gc
- IECEX dust certificate - IECEx PTB 09.0001X
- IECEX gas certificate - IECEx PTB 12.0003X
- Installation - in Zone 2, Division 2 and in safe area
General
- Functional Description - R. STAHL's 9004 series INTRINSPAK single-channel safety barriers are ideally suited to supplying field devices with intrinsically safe auxiliary power due to their electronic current limitation. They have a particularly good power yield and are available in many variants for circuits with a negative or positive potential, including for unregulated power supplies.
- Highlights - For supplying field devices with intrinsically safe auxiliary power, variants for many applications flexible, space-saving devices that are easy to install on a DIN rail reduced storage due to standardised back-up fuse
- Particularly suitable for - Exi power supply, solenoid valves
- Product Description - Single-channel safety barriers With electronic current limiting
- Product Type - 9004/01-280-045-001
- Product Variant - Series 9004/01, for positive potential
- Title Product Variant Technical Data - 9004/01-280-045-001 safety barrier
- WebCode - 9004A
Mechanical Data
- Clamping range max. - 1.50 mm²
- Connection cross-section - 4.0 mm²
- Degree of protection (IP) - IP40
- Enclosure material - Polyamide 6GF
- Length - 12.000 mm
- Mounting depth - 72.000 mm
- Number of connection terminals - 4
- Terminal degree of protection (IP) - IP20
- Type of connection cable - Finely stranded, solid
- Weight - 0.120 kg
- Width - 103.000 mm
Mounting / Installation
- Connection type - 2 PA
Safety Data
- Max. Current I o - 45.0 mA
- Max. permissible external capacitance C o for IIB - 0.280 μF
- Max. permissible external inductance L o for IIB - 1.500 mH
- Max. Power P o - 1260.000 mW
- Max. Voltage U o - 28.00 V
159084
For supplying field devices with intrinsically safe auxiliary power, variants for many applications
flexible, space-saving devices that are easy to install on a DIN rail
reduced storage due to standardised back-up fuse
Ambient Conditions
- Ambient temperature - -20 °C ... +60 °C
- Ambient temperature max. - +60 °C
- Ambient temperature min. - -20 °C
- Relative humidity max. - 95% on average, no condensation
- Storage temperature - -20 °C ... +75 °C
- Storage temperature max. - +75 °C
- Storage temperature min. - -20 °C
- Temperature influence - ≤ 0,25 %/10K
Auxiliary power
- Nominal voltage - 26.00 V
- Power supply - Controlled, nominal voltage
Electrical Data
- Max. resistance R max - 73.00 Ω
- Maximum output current I max - 20 mA
- Min. resistance R min - 67.00 Ω
- Number of channels - 1
- Potential - negative potential
- Rated operational voltage DC - 26.00 V
- Transmission frequency in case of electrical current limiting - ≤ 10 kHz
Explosion Protection
- Application range (zones) - 2, 22
- ATEX dust certificate - PTB 01 ATEX 2088 X
- ATEX gas certificate - PTB 02 ATEX 2008
- Certificates - ATEX (PTB), Canada (CSA), IECEx (PTB)
- Dust explosion protection ATEX - II (2) D [Ex ib Db] IIIC
- Dust explosion protection IECEx - [Ex ib Db] IIIC
- Ex interface zone - 1, 2, 21, 22
- Further information - see respective certificate and operating instructions
- Gas explosion protection ATEX - II 3 (2) G Ex nA [ib Gb] IIB/IIC T4 Gc
- Gas explosion protection IECEx - Ex nA [ib Gb] IIB/IIC T4 Gc
- IECEX dust certificate - IECEx PTB 09.0001X
- IECEX gas certificate - IECEx PTB 12.0003X
- Installation - in Zone 2, Division 2 and in safe area
General
- Functional Description - R. STAHL's 9004 series INTRINSPAK single-channel safety barriers are ideally suited to supplying field devices with intrinsically safe auxiliary power due to their electronic current limitation. They have a particularly good power yield and are available in many variants for circuits with a negative or positive potential, including for unregulated power supplies.
- Highlights - For supplying field devices with intrinsically safe auxiliary power, variants for many applications flexible, space-saving devices that are easy to install on a DIN rail reduced storage due to standardised back-up fuse
- Particularly suitable for - Exi power supply, solenoid valves
- Product Description - Single-channel safety barriers With electronic current limiting
- Product Type - 9004/00-315-025-001
- Product Variant - Series 9004/00, for negative potential
- Title Product Variant Technical Data - 9004/00-315-025-001 safety barrier
- WebCode - 9004A
Mechanical Data
- Clamping range max. - 1.50 mm²
- Connection cross-section - 4.0 mm²
- Degree of protection (IP) - IP40
- Enclosure material - Polyamide 6GF
- Length - 12.000 mm
- Mounting depth - 72.000 mm
- Number of connection terminals - 4
- Terminal degree of protection (IP) - IP20
- Type of connection cable - Finely stranded, solid
- Weight - 0.120 kg
- Width - 103.000 mm
Mounting / Installation
- Connection type - 2 PA
Safety Data
- Max. Current I o - 25.0 mA
- Max. permissible external capacitance C o for IIB - 0.230 μF
- Max. permissible external inductance L o for IIB - 2.500 mH
- Max. Power P o - 787.500 mW
- Max. Voltage U o - 31.50 V
159086
For supplying field devices with intrinsically safe auxiliary power, variants for many applications
flexible, space-saving devices that are easy to install on a DIN rail
reduced storage due to standardised back-up fuse
Ambient Conditions
- Ambient temperature - -20 °C ... +60 °C
- Ambient temperature max. - +60 °C
- Ambient temperature min. - -20 °C
- Relative humidity max. - 95% on average, no condensation
- Storage temperature - -20 °C ... +75 °C
- Storage temperature max. - +75 °C
- Storage temperature min. - -20 °C
- Temperature influence - ≤ 0,25 %/10K
Auxiliary power
- Nominal voltage - 26.00 V
- Power supply - Controlled, nominal voltage
Electrical Data
- Max. resistance R max - 73.00 Ω
- Maximum output current I max - 20 mA
- Min. resistance R min - 67.00 Ω
- Number of channels - 1
- Potential - positive potential
- Rated operational voltage DC - 26.00 V
- Transmission frequency in case of electrical current limiting - ≤ 10 kHz
Explosion Protection
- Application range (zones) - 2, 22
- ATEX dust certificate - PTB 01 ATEX 2088 X
- ATEX gas certificate - PTB 02 ATEX 2008
- Certificates - ATEX (PTB), Canada (CSA), IECEx (PTB)
- Dust explosion protection ATEX - II (2) D [Ex ib Db] IIIC
- Dust explosion protection IECEx - [Ex ib Db] IIIC
- Ex interface zone - 1, 2, 21, 22
- Further information - see respective certificate and operating instructions
- Gas explosion protection ATEX - II 3 (2) G Ex nA [ib Gb] IIB/IIC T4 Gc
- Gas explosion protection IECEx - Ex nA [ib Gb] IIB/IIC T4 Gc
- IECEX dust certificate - IECEx PTB 09.0001X
- IECEX gas certificate - IECEx PTB 12.0003X
- Installation - in Zone 2, Division 2 and in safe area
General
- Functional Description - R. STAHL's 9004 series INTRINSPAK single-channel safety barriers are ideally suited to supplying field devices with intrinsically safe auxiliary power due to their electronic current limitation. They have a particularly good power yield and are available in many variants for circuits with a negative or positive potential, including for unregulated power supplies.
- Highlights - For supplying field devices with intrinsically safe auxiliary power, variants for many applications flexible, space-saving devices that are easy to install on a DIN rail reduced storage due to standardised back-up fuse
- Particularly suitable for - Exi power supply, solenoid valves
- Product Description - Single-channel safety barriers With electronic current limiting
- Product Type - 9004/01-315-025-001
- Product Variant - Series 9004/01, for positive potential
- Title Product Variant Technical Data - 9004/01-315-025-001 safety barrier
- WebCode - 9004A
Mechanical Data
- Clamping range max. - 1.50 mm²
- Connection cross-section - 4.0 mm²
- Degree of protection (IP) - IP40
- Enclosure material - Polyamide 6GF
- Length - 12.000 mm
- Mounting depth - 72.000 mm
- Number of connection terminals - 4
- Terminal degree of protection (IP) - IP20
- Type of connection cable - Finely stranded, solid
- Weight - 0.120 kg
- Width - 103.000 mm
Mounting / Installation
- Connection type - 2 PA
Safety Data
- Max. Current I o - 25.0 mA
- Max. permissible external capacitance C o for IIB - 0.230 μF
- Max. permissible external inductance L o for IIB - 2.500 mH
- Max. Power P o - 787.500 mW
- Max. Voltage U o - 31.50 V
159090
For supplying field devices with intrinsically safe auxiliary power, variants for many applications
flexible, space-saving devices that are easy to install on a DIN rail
reduced storage due to standardised back-up fuse
Ambient Conditions
- Ambient temperature - -20 °C ... +60 °C
- Ambient temperature max. - +60 °C
- Ambient temperature min. - -20 °C
- Relative humidity max. - 95% on average, no condensation
- Storage temperature - -20 °C ... +75 °C
- Storage temperature max. - +75 °C
- Storage temperature min. - -20 °C
- Temperature influence - ≤ 0,25 %/10K
Auxiliary power
- Nominal voltage - 23.00 ... 27.00 V
- Power supply - Uncontrolled, 23 - 27 V DC
Electrical Data
- Maximum output current I max - 40 mA
- Number of channels - 1
- Potential - +Potential with voltage limit
- Transmission frequency in case of electrical current limiting - ≤ 10 kHz
Explosion Protection
- Application range (zones) - 2, 22
- ATEX dust certificate - PTB 01 ATEX 2088 X
- ATEX gas certificate - PTB 02 ATEX 2008
- Certificates - ATEX (PTB), Canada (CSA), IECEx (PTB)
- Dust explosion protection ATEX - II (2) D [Ex ib Db] IIIC
- Dust explosion protection IECEx - [Ex ib Db] IIIC
- Ex interface zone - 1, 2, 21, 22
- Further information - see respective certificate and operating instructions
- Gas explosion protection ATEX - II 3 (2) G Ex nA [ib Gb] IIB/IIC T4 Gc
- Gas explosion protection IECEx - Ex nA [ib Gb] IIB/IIC T4 Gc
- IECEX dust certificate - IECEx PTB 09.0001X
- IECEX gas certificate - IECEx PTB 12.0003X
- Installation - in Zone 2, Division 2 and in safe area
General
- Functional Description - R. STAHL's 9004 series INTRINSPAK single-channel safety barriers are ideally suited to supplying field devices with intrinsically safe auxiliary power due to their electronic current limitation. They have a particularly good power yield and are available in many variants for circuits with a negative or positive potential, including for unregulated power supplies.
- Highlights - For supplying field devices with intrinsically safe auxiliary power, variants for many applications flexible, space-saving devices that are easy to install on a DIN rail reduced storage due to standardised back-up fuse
- Particularly suitable for - Exi power supply, solenoid valves
- Product Description - Single-channel safety barriers With electronic current limiting
- Product Type - 9004/51-206-050-001
- Product Variant - Series 9004/51, for positive potential with voltage limitation
- Title Product Variant Technical Data - 9004/51-206-050-001 safety barrier
- WebCode - 9004A
Mechanical Data
- Clamping range max. - 1.50 mm²
- Connection cross-section - 4.0 mm²
- Degree of protection (IP) - IP40
- Enclosure material - Polyamide 6GF
- Length - 12.000 mm
- Mounting depth - 72.000 mm
- Number of connection terminals - 4
- Terminal degree of protection (IP) - IP20
- Type of connection cable - Finely stranded, solid
- Weight - 0.120 kg
- Width - 103.000 mm
Mounting / Installation
- Connection type - 2 PA
Safety Data
- Max. Current I o - 50.0 mA
- Max. permissible external capacitance C o for IIB - 0.580 μF
- Max. permissible external inductance L o for IIB - 2.500 mH
- Max. Power P o - 1030.000 mW
- Max. Voltage U o - 20.60 V
159094
For supplying field devices with intrinsically safe auxiliary power, variants for many applications
flexible, space-saving devices that are easy to install on a DIN rail
reduced storage due to standardised back-up fuse
Ambient Conditions
- Ambient temperature - -20 °C ... +60 °C
- Ambient temperature max. - +60 °C
- Ambient temperature min. - -20 °C
- Relative humidity max. - 95% on average, no condensation
- Storage temperature - -20 °C ... +75 °C
- Storage temperature max. - +75 °C
- Storage temperature min. - -20 °C
- Temperature influence - ≤ 0,25 %/10K
Auxiliary power
- Nominal voltage - 23.00 ... 27.00 V
- Power supply - Uncontrolled, 23 - 27 V DC
Electrical Data
- Maximum output current I max - 70 mA
- Number of channels - 1
- Potential - +Potential with voltage limit
- Transmission frequency in case of electrical current limiting - ≤ 10 kHz
Explosion Protection
- Application range (zones) - 2, 22
- ATEX dust certificate - PTB 01 ATEX 2088 X
- ATEX gas certificate - PTB 02 ATEX 2008
- Certificates - ATEX (PTB), Canada (CSA), IECEx (PTB)
- Dust explosion protection ATEX - II (2) D [Ex ib Db] IIIC
- Dust explosion protection IECEx - [Ex ib Db] IIIC
- Ex interface zone - 1, 2, 21, 22
- Further information - see respective certificate and operating instructions
- Gas explosion protection ATEX - II 3 (2) G Ex nA [ib Gb] IIB/IIC T4 Gc
- Gas explosion protection IECEx - Ex nA [ib Gb] IIB/IIC T4 Gc
- IECEX dust certificate - IECEx PTB 09.0001X
- IECEX gas certificate - IECEx PTB 12.0003X
- Installation - in Zone 2, Division 2 and in safe area
General
- Functional Description - R. STAHL's 9004 series INTRINSPAK single-channel safety barriers are ideally suited to supplying field devices with intrinsically safe auxiliary power due to their electronic current limitation. They have a particularly good power yield and are available in many variants for circuits with a negative or positive potential, including for unregulated power supplies.
- Highlights - For supplying field devices with intrinsically safe auxiliary power, variants for many applications flexible, space-saving devices that are easy to install on a DIN rail reduced storage due to standardised back-up fuse
- Particularly suitable for - Exi power supply, solenoid valves
- Product Description - Single-channel safety barriers With electronic current limiting
- Product Type - 9004/51-206-085-001
- Product Variant - Series 9004/51, for positive potential with voltage limitation
- Title Product Variant Technical Data - 9004/51-206-085-001 safety barrier
- WebCode - 9004A
Mechanical Data
- Clamping range max. - 1.50 mm²
- Connection cross-section - 4.0 mm²
- Degree of protection (IP) - IP40
- Enclosure material - Polyamide 6GF
- Length - 12.000 mm
- Mounting depth - 72.000 mm
- Number of connection terminals - 4
- Terminal degree of protection (IP) - IP20
- Type of connection cable - Finely stranded, solid
- Weight - 0.126 kg
- Width - 103.000 mm
Mounting / Installation
- Connection type - 2 PA
Safety Data
- Max. Current I o - 85.0 mA
- Max. permissible external capacitance C o for IIB - 0.680 μF
- Max. permissible external inductance L o for IIB - 0.370 mH
- Max. Power P o - 1751.000 mW
- Max. Voltage U o - 20.60 V
159097
For supplying field devices with intrinsically safe auxiliary power, variants for many applications
flexible, space-saving devices that are easy to install on a DIN rail
reduced storage due to standardised back-up fuse
Ambient Conditions
- Ambient temperature - -20 °C ... +60 °C
- Ambient temperature max. - +60 °C
- Ambient temperature min. - -20 °C
- Relative humidity max. - 95% on average, no condensation
- Storage temperature - -20 °C ... +75 °C
- Storage temperature max. - +75 °C
- Storage temperature min. - -20 °C
- Temperature influence - ≤ 0,25 %/10K
Auxiliary power
- Nominal voltage - 24.00 ... 26.00 V
- Power supply - Uncontrolled, 24 - 26 V DC
Electrical Data
- Maximum output current I max - 25 mA
- Number of channels - 1
- Potential - -Potential with voltage limit
- Transmission frequency in case of electrical current limiting - ≤ 10 kHz
Explosion Protection
- Application range (zones) - 2, 22
- ATEX dust certificate - PTB 01 ATEX 2088 X
- ATEX gas certificate - PTB 02 ATEX 2008
- Certificates - ATEX (PTB), Canada (CSA), IECEx (PTB)
- Dust explosion protection ATEX - II (2) D [Ex ib Db] IIIC
- Dust explosion protection IECEx - [Ex ib Db] IIIC
- Ex interface zone - 1, 2, 21, 22
- Further information - see respective certificate and operating instructions
- Gas explosion protection ATEX - II 3 (2) G Ex nA [ib Gb] IIB/IIC T4 Gc
- Gas explosion protection IECEx - Ex nA [ib Gb] IIB/IIC T4 Gc
- IECEX dust certificate - IECEx PTB 09.0001X
- IECEX gas certificate - IECEx PTB 12.0003X
- Installation - in Zone 2, Division 2 and in safe area
General
- Functional Description - R. STAHL's 9004 series INTRINSPAK single-channel safety barriers are ideally suited to supplying field devices with intrinsically safe auxiliary power due to their electronic current limitation. They have a particularly good power yield and are available in many variants for circuits with a negative or positive potential, including for unregulated power supplies.
- Highlights - For supplying field devices with intrinsically safe auxiliary power, variants for many applications flexible, space-saving devices that are easy to install on a DIN rail reduced storage due to standardised back-up fuse
- Particularly suitable for - Exi power supply, solenoid valves
- Product Description - Single-channel safety barriers With electronic current limiting
- Product Type - 9004/50-220-030-001
- Product Variant - Series 9004/50, for negative potential with voltage limitation
- Title Product Variant Technical Data - 9004/50-220-030-001 safety barrier
- WebCode - 9004A
Mechanical Data
- Clamping range max. - 1.50 mm²
- Connection cross-section - 4.0 mm²
- Degree of protection (IP) - IP40
- Enclosure material - Polyamide 6GF
- Length - 12.000 mm
- Mounting depth - 72.000 mm
- Number of connection terminals - 4
- Terminal degree of protection (IP) - IP20
- Type of connection cable - Finely stranded, solid
- Weight - 0.119 kg
- Width - 103.000 mm
Mounting / Installation
- Connection type - 2 PA
Safety Data
- Max. Current I o - 30.0 mA
- Max. permissible external capacitance C o for IIB - 0.550 μF
- Max. permissible external capacitance C o for IIC - 0.073 μF
- Max. permissible external inductance L o for IIB - 2.500 mH
- Max. permissible external inductance L o for IIC - 1.300 mH
- Max. Power P o - 660.000 mW
- Max. Voltage U o - 22.00 V