Yodify Product Library
Instantly add the Rotamass 3 RCCS3 Remote Detector and 50,000+ more product series to your store or catalog
Book Your Demo and See How
or create your store
Rotamass 3 RCCS3 Remote Detector
Brand: Yokogawa Electric CorporationROTAMASS is a Coriolis mass flowmeter with highly refined digital signal processing electronics, so that accurate and stable mass flow measurement is achieved.
ROTAMASS employs a flame-proof type converter case suitable for use in the hazardous area together with it’s intrinsically safety type detector.
ROTAMASS's signal processing, housing protection and its detector's special decoupling system against external loads and vibrations, realize high performance in real applications.
Features- ROTAMASS is a flowmeter for nearly all fluids, including high viscosity liquids, slurries and multi-phase media with a certain gas content
- Field-mount and Rack-mount remote converter available
- Refined digital signal processing enables accurate and stable measurement
- A special detector decoupling system makes the device highly independent from external loads or vibrations
- Simple flow path means self-draining, simple cleaning and suitable for use in hygenic industries
- High accuracy and high stability over a wide flow range
- Accurate density measurement, up to ±0.0005 g/cm³
- Concentration measurement for solutions, suspensions and emulsions (Example: Water cut, net oil computing)
- Volume flow with reference density
- Temperature measurement
- Two Analog outputs, two pulse outputs or status-out and one status-in as standard I/O
- Available in Explosion proof versions (ATEX, FM, IECEx, EAC, INMETRO, NEPSI, KOSHA)
- European MID approval according to OIML R-117-1 and American NTEP approval for Custody Transfer Measurement
- Wide process temperature range -200° to 350° C
- Microprocessor-based multifunction capability
- EEPROM protects parameter settings and totalized values during power failure
- High visibly LCD display
- HART communication function is available
- Optional Foundation™ Fieldbus communication is available
- Optional MODBUS® communication is available
- Optional intrinsically safe outputs are available
- Various choice of tubes materials
- EN, ASME or JIS flanges as standard
- SIL 2, SIL 3 levels can be achieved if redundant meters are used
Specifications
Accuracy
- ± 0.0005 g/cm³ - Density Calibration with 3 Different Fluids Including Individual Temperature Compensation
- ± 0.001 g/cm³ - Density Adjustment & Thermal Treatment
- ± 0.0015 to ± 0.02 g/cm³ (Standard)
- ± 0.1 % of Flow Rate ± Zero Stability/Flow Rate *100 % - Mass Flow (Liquid RCCS30-39/XR)
- ± 0.15 % of Flow Rate ± Zero Stability/Flow Rate *100 % - Mass Flow (Liquid RCCS30LR)
- ± 0.5 % of Flow Rate ± Zero Stability/Flow Rate *100 % - Mass Flow (Gas)
Ambient Temperature Range
- -50° to 80° C (-58° to 176° F)
Approvals & Certifications
- American NTEP Approval 12-080A2 for Custody Transfer Measurement
- ATEX: KEMA 02-ATEX-2183 x & KEMA 01-ATEX-1075 X, Flameproof & Intrinsically Safe
- CRN 0F12074.5 Approved Process Connections
- EAC: Flameproof & Intrinsically Safe
- EHEDG
- EMC: EN 61326-1: 2006, Class A, EN 61326-2-3: 2006, EN 61000-3-2: 2006 & EN 61000-3-3: 2008
- European MID Approval According to OIML R-117-1 (Fluids other than Water)
- FM: Intrinsically Safe & Housing Explosion-proof
- GOST
- IEC Ex: KEM 06.0031X, Intrinsically Safe, Flameproof
- INMETRO: Flameproof & Intrinsically Safe
- KOSHA
- NAMUR: EN 60947-5-6
- NEPSI: Flameproof & Intrinsically Safe
- PED 97/23/EC
Approvals & Certifications
- Compliance According to EN 10204: 2004-2.1
- Dye Penetration Test According to DIN EN ISO 3452-1
- Mass/Volume-Flow Calibration Using Water with Factory Calibration Certification
- Mass/Volume-Flow Calibration with DAkkS Certificate EN 17025: 2005
- Material Certificate According to EN 10204: 2004 -3.1
- PMI
- Pressure Test Report Measuring System
- SIL 2, SIL 3 (FMEDA Report)
BSP Connection
- G 1/2” Female
- G 1/4” Female
- G 3/4” Female
Cable Length
- ≤ 6,562 feet (2,000 metres)
Communication
- Baud Rate: 1,200, 2,400, 4,800, 9,600, 19,200, 38,400, 57,600, 115,200 bit/sec
- FOUNDATION Fieldbus
- HART
- Modbus ASCII/RTU
- Modbus Via RS-485 as 2-Wire Data Bus According to EIA/TIA-485
Conduit Connection
- 1/2” NPT Female
- M20 x 1.5 Female
Consumption
- 10 W, Max.
- 25 VA, Max.
Damping Adjustment
- 0 to 200 seconds
Display
- LCD Display
Electrical Protection
- Lightning Protection - Arresters 2,000 A are Inside of the Converter for Power Supply Lines
Electrical Rating
- 5 A at 250 V - External Circuit Breaker Rating
Enclosure, Body Material
- 304 Stainless Steel, 1.4301 - Detector Insulation Housing
Environmental Protection
- Explosion-proof
- Flameproof
- Heat Tracing: IP54 (Install Roof Protected)
- Intrinsically Safe
- IP66
- IP67
- NEMA 4X
Flange Size - 1-1/2” (DN 40)
- 1-1/2” (DN 40) - 150# ASME
- 1-1/2” (DN 40) - 1500# ASME
- 1-1/2” (DN 40) - 300# ASME
- 1-1/2” (DN 40) - 600# ASME
- 1-1/2” (DN 40) - 900# ASME
- 1-1/2” (DN 40) - JIS 10K
- 1-1/2” (DN 40) - JIS 20K
- 1-1/2” (DN 40) - PN 100
- 1-1/2” (DN 40) - PN 40
Flange Size - 1” (DN 25)
- 1” (DN 25) - 150# ASME
- 1” (DN 25) - 1500# ASME
- 1” (DN 25) - 300# ASME
- 1” (DN 25) - 600# ASME
- 1” (DN 25) - 900# ASME
- 1” (DN 25) - JIS 10K
- 1” (DN 25) - JIS 20K
- 1” (DN 25) - PN 100
- 1” (DN 25) - PN 40
Flange Size - 1/2” (DN 15)
- 1/2” (DN 15) - 150# ASME
- 1/2” (DN 15) - 1500# ASME
- 1/2” (DN 15) - 300# ASME
- 1/2” (DN 15) - 600# ASME
- 1/2” (DN 15) - 900# ASME
- 1/2” (DN 15) - JIS 10K
- 1/2” (DN 15) - JIS 20K
- 1/2” (DN 15) - PN 100
- 1/2” (DN 15) - PN 40
Flange Size - 2-1/2” (DN 65)
- 2-1/2” (DN 65) - 150# ASME
- 2-1/2” (DN 65) - 300# ASME
- 2-1/2” (DN 65) - 600# ASME
- 2-1/2” (DN 65) - 900# ASME
Flange Size - 2” (DN 50)
- 2” (DN 50) - 150# ASME
- 2” (DN 50) - 1500# ASME
- 2” (DN 50) - 300# ASME
- 2” (DN 50) - 600# ASME
- 2” (DN 50) - 900# ASME
- 2” (DN 50) - JIS 10K
- 2” (DN 50) - JIS 20K
- 2” (DN 50) - PN 100
- 2” (DN 50) - PN 40
- 2” (DN 50) - PN 63
Flange Size - 3” (DN 80)
- 3” (DN 80) - 150# ASME
- 3” (DN 80) - 300# ASME
- 3” (DN 80) - 600# ASME
- 3” (DN 80) - 900# ASME
- 3” (DN 80) - JIS 10K
- 3” (DN 80) - JIS 20K
- 3” (DN 80) - PN 100
- 3” (DN 80) - PN 40
- 3” (DN 80) - PN 63
Flange Size - 4” (DN 100)
- 4” (DN 100) - 150# ASME
- 4” (DN 100) - 300# ASME
- 4” (DN 100) - 600# ASME
- 4” (DN 100) - JIS 10K
- 4” (DN 100) - JIS 20K
- 4” (DN 100) - PN 100
- 4” (DN 100) - PN 16
- 4” (DN 100) - PN 40
- 4” (DN 100) - PN 63
Flange Size - 5” (DN 125)
- 5” (DN 125) - 150# ASME
- 5” (DN 125) - 300# ASME
- 5” (DN 125) - 600# ASME
- 5” (DN 125) - JIS 10K
- 5” (DN 125) - JIS 20K
- 5” (DN 125) - PN 100
- 5” (DN 125) - PN 16
- 5” (DN 125) - PN 40
- 5” (DN 125) - PN 63
Flange Size - 6” (DN 150)
- 6” (DN 150) - 150# ASME
- 6” (DN 150) - 300# ASME
- 6” (DN 150) - 600# ASME
- 6” (DN 150) - JIS 10K
- 6” (DN 150) - JIS 20K
- 6” (DN 150) - PN 100
- 6” (DN 150) - PN 16
- 6” (DN 150) - PN 40
- 6” (DN 150) - PN 63
Flange Size - 8” (DN 200)
- 8” (DN 200) - 150# ASME
- 8” (DN 200) - 300# ASME
- 8” (DN 200) - 600# ASME
- 8” (DN 200) - PN 16
- 8” (DN 200) - PN 40
- 8” (DN 200) - PN 63
Flange Type
- RTJ - Ring Typical Joint
Frequency
- 20 to 10,000 Hz - Frequency Output 1
- 20 to 2,000 Hz - Frequency Output 2
Humidity
- 0 to 95 % Relative Humidity - Ambient Humidity Range
Linearity
- 0.05 % of Span Equal to 0.008 mA
Materials of Construction
- 304 Stainless Steel, 1.4301 - Name Plate, Mounting Bracket
- 316L Stainless Steel, 1.4401 - Detector Terminal Box, Rupture Disk
Measuring Range
- 0.3 to 2.5 kg/L - Density Measurement
Media
- Gas
- Liquids
- Slurry
Mounting
- 2” Pipe Mounting Bracket
- Field Mounting Converter
- Rack-Mounted Converter
NACE & NIST
- NIST
NPT Connection
- 1/2” NPT Female
- 1/4” NPT Female
- 3/4” NPT Female
Output
- 30 Vdc / 200 mA - Passive Transistor Contact Output, According EN 60947-5-6
- 4-20 mA DC, Galvanically Separated from Other Signals
- Active Output, 12 V, 6 mA, Resistance > 10 kiloohms
Plug Material
- 303 Stainless Steel, 1.4305 - Detector Gas Filling Plug
Power
- 2 A, T, Breaking Capacity 1,500 A - Fuse on Base Board (AC & DC-Typical)
Power Supply
- 20.5-28.8 Vdc - DC-Typical
- 24 Vdc
- 90-250 Vac - AC Ex-Typical
- 90-264 Vac - AC-Typical
Pressure Range
- psi: 0 to 5,800 (kPa: 0 to 40,000, bar: 0 to 400) - Process Pressure Limit
Principle of Operation
- Coriolis Principle
Process Connection Material
- 316L Stainless Steel, 1.4404, 1.4435
Process Temperature
- -200° to 350° C (-328° to 662° F)
Pulse Range
- 0 to 10,000 Pulses/seconds - Output 1
- 0 to 2,000 Pulses/second - Output 2
Repeatability
- ± 0.0002 g/cm³ - Density Calibration
- ± 0.0005 g/cm³
- ± 0.05 % ± (Zero Stability/2)/Flow Rate *100 % - Repeatability of Liquids
Resistance
- 100 kiloohms - Status Input (Open)
- > 100 megaohms / 500 Vdc between Power & Ground Terminal (Isolation Resistance of Converter)
- > 20 megaohms / 100 Vdc between Power & I/O Terminals, I/O Terminals & Ground (Isolation Resistance of Converter)
- 20 to 600 ohms - Load Resistance (I/O Signal)
Supply Voltage
- 1,500 Vac for 1 Minute between Power & Ground Terminal (Dielectric Strength)
- 10.5-30 Vdc (without HART), 165 mA
- 16.75-30 Vdc (with HART), 165 mA
Temperature Effect
- < 0.05 % of Span Per 10° C (18° F) - Ambient Temperature Effect (I/O Signal)
- ± 0.000015 g/cm³ * Absolute [T-Medium - 20° C] - Process Temperature Influence (Density Calibration)
Tri-Clamp Connection
- 1” Tri-Clamp
- 1/2” Tri-Clamp
- 1-1/2” Tri-Clamp
- 2” Tri-Clamp
- 3” Tri-Clamp
- 4” Tri-Clamp
Wetted Materials
- Hastelloy C-22
- Nickel Alloy C-22 / 2.4602 - Measuring Tube & Flange Face