Yodify Product Library
Add the GX90XD Digital Input Module to your store or catalog  
Book Your Demo and See How
or create your store

Decades of Yokogawa's innovative measuring technology has resulted in a flexible data logger that offers both reliability and ease of use.
Features
  • Scalability
    • Up to 420 channels per system
    • Plug and lock modules
  • Ease of Use
    • Web-based configuration
    • Live web-based data viewing
  • Mobile Connectivity
    • Bluetooth
    • Mobile application 
  • Reliability
    • Secure data storage
    • High accuracy measurement
    • Automatic backfill function (GA10 data logging software)
  • Noise Tolerance
    • Electromagnetic relay module

Specifications

Approvals & Certifications

  • CE
  • CSA
  • GOST
  • KC
  • NRTL
  • UL 61010-1, UL 61010-2-030 (CSA NRTL/C)

Channels

  • 16

Communication

  • Bluetooth
  • DARWIN
  • Ethernet - 10Base-T/100Base-TX Port
  • EtherNet/IP
  • Modbus RTU
  • Modbus TCP/IP
  • RS-422, RS-485
  • Serial Communication Port
  • SSL
  • USB 2.0

Current

  • Leakage Current 0.5 mA or Less when OFF - Open Collector

Electrical Connectors

  • M3 Screw Terminal

Electrical Rating

  • 20 mA or more at 12 Vdc

Frequency

  • 50/60 Hz ± 1 %

Humidity

  • 55 ± 10 % RH, 23 ± 2° C (73.4 ± 3.6° F) - General Operating Condition

Input

  • 0.32 to 5.2 V to Standard Signal
  • 0-20 mA DC
  • 10 V - Allowable Input Voltage
  • -200 mV to 50 V - DCV
  • 4-20 mA DC - Standard Signal
  • Non-Voltage Contact
  • Open Collector

Insulation Resistance

  • 20 MΩ or greater at 500 Vdc between Input Terminals & Internal Circuitry

Measurement Accuracy

  • DCV: ± (0.01 % of Reading + 2 mV) - 6 V (1-5 V)
  • DCV: ± (0.01 % of Reading + 5 μV) - 20 mV
  • ± [0.02 % of Reading + 0.16° C (0.288° F)] - Pt100 (High Resolution)
  • ± [0.02 % of Reading + 0.2° C (0.36° F)] - Pt100
  • ± 0.2° C (± 0.36° F) However, -200° to 0° C (-328° to 0° F): ± [0.15 % of Reading + 0.2° C (32.36° F)] - K Thermocouple [-200° to 500° C (-328° to 932° F)]
  • ± 0.2° C (± 0.36° F), However, -200° to 0° C (-328° to 0° F): ± [0.10 % of Reading + 0.2° C (0.36° F)] - T Thermocouple
  • ± 1.1° C (± 1.98° F) - R Thermocouple

Mounting

  • Clamp Terminal
  • Desktop
  • DIN Rail
  • Wall Mounted

Operating Temperature

  • -20° to 60° C (-4° to 140° F)

Pulse Range

  • Pulse Width: 2 ms, max.

Resistance

  • 200 ohms or Less when ON - Contact Resistance Non-Voltage Contact
  • 50 kΩ or more when OFF - Contact Resistance Non-Voltage Contact
  • Approximately 1 Kiloohm - Input Resistance

RTD Type

  • Cu10
  • Cu100
  • Cu25
  • Cu50
  • Cu53
  • JPt100
  • Ni100
  • Ni120
  • Pt100
  • Pt200
  • Pt25
  • Pt46
  • Pt50

Sensor, Probe Type

  • B Thermocouple
  • E Thermocouple
  • J Thermocouple
  • K Thermocouple
  • L Thermocouple
  • N Thermocouple
  • RTD
  • R Thermocouple
  • S Thermocouple
  • T Thermocouple
  • U Thermocouple
  • W Thermocouple

Supply Voltage

  • 0.5 Vdc or Less when ON - Open Collector
  • 1,500 Vac, 1 Minute between Input Terminals & Internal Circuitry - Withstand Voltage
  • 180-264 Vac
  • 90-132 Vac

Temperature Range

  • -200° to 850° C (-328° to 1,562° F) - RTD
  • -270° to 2,320° C (-454° to 4,208° F) - Thermocouples

Update Time

  • 30 minutes - Warm-Up Time
Instantly populate your store or catalog 
CREATE YOUR SITE
or book a demo with the Yodify Team
show more