DS09/DI13/DI16 Ultra-High Accuracy Transfer Standard Pyrometer

Brand: Process Sensors Corporation

Ultra-High Accuracy digital transfer standard pyrometer for high-precision inspection of calibration sources.
Features
  • Thermostatically controlled detector 
  • High-resolution A/D and D/A converters, directly digitized 
  • Analog output with 16-bit temperature resolution for high accuracy voltage output 
  • Consequential design configuration in separate galvanically isolated circuits 
  • Extremely long-term stable components 
  • High quality achromatic lenses 

1 - 9 of 9 Part Numbers
DI13 OD09-A0
DI13 OD09-A0
  • Model - 1,000° to 3,500° C (1,832° to 6,332° F)
  • Optics - Measuring Distance: 600 mm
DI13 OD09-B0
DI13 OD09-B0
  • Model - 1,000° to 3,500° C (1,832° to 6,332° F)
  • Optics - Measuring Distance: 800 mm
DI13 OD09-C0
DI13 OD09-C0
  • Model - 1,000° to 3,500° C (1,832° to 6,332° F)
  • Optics - Measuring Distance: 1,200 mm
DI16 OD09-A0
DI16 OD09-A0
  • Model - 250° to 1,500° C (482° to 2,732° F)
  • Optics - Measuring Distance: 600 mm
DI16 OD09-B0
DI16 OD09-B0
  • Model - 250° to 1,500° C (482° to 2,732° F)
  • Optics - Measuring Distance: 800 mm
DI16 OD09-C0
DI16 OD09-C0
  • Model - 250° to 1,500° C (482° to 2,732° F)
  • Optics - Measuring Distance: 1,200 mm
DS09 OD09-A0
DS09 OD09-A0
  • Model - 600° to 1,800° C (1,112° to 3,272° F)
  • Optics - Measuring Distance: 600 mm
DS09 OD09-B0
DS09 OD09-B0
  • Model - 600° to 1,800° C (1,112° to 3,272° F)
  • Optics - Measuring Distance: 800 mm
DS09 OD09-C0
DS09 OD09-C0
  • Model - 600° to 1,800° C (1,112° to 3,272° F)
  • Optics - Measuring Distance: 1,200 mm
1 - 9 of 9 Part Numbers

Specifications

Accuracy

  • 0.15 % of Measured Value + 1K

Ambient Temperature Range

  • 0° to 50° C (32° to 122° F)

Approvals & Certifications

  • CE EU Directives for Electromagnetic Immunity
  • IEC 60825-1

Communication

  • Baud Rate: 4.8 to 115.2 K
  • Half-Duplex
  • Serial Interface: RS-485

Display

  • 10-Digit LED Display (5 mm High) for Temperature in °C or °F

Distance

  • Measuring Distance: 23.6 to 47.2” (600 to 1,200 mm)

Enclosure, Body Material

  • Aluminum

Environmental Protection

  • IP65

Load

  • > 100 kiloohms

Output

  • Analog: 0-10 Vdc

Power Requirement

  • 18-30 Vdc
  • 24 Vdc
  • Maximum

Range

  • Spectral DI13: 1.27 µm
  • Spectral DI16: 1.45 to 1.8 µm
  • Spectral DS09: 0.7 to 1.1 µm

Repeatability

  • 0.06 % of Measured Value

Resolution

  • Serial Interface: 0.01° C or 0.01° F
  • Serial Interface: 16-bit

Response Time

  • 1 millisecond (with Dynamical Adaptation at Low Signal Levels), Adjustable up to 10 seconds

Storage Temperature

  • -20° to 70° C (-4° to 158° F)

Temperature Coefficient

  • 32 ppm/°C Ambient Temperature Change in a Range of 10° to 40° C

Temperature Range

  • 250° to 3,500° C (482° to 6,332° F)

Uncertainty

  • Up to 1,500° C: 0.15 % of Measured Value in °C+1K
  • Up to 2,500° C: 0.2 % of Measured Value in °C
  • Up to 3,000° C: 0.3 % of Measured Value in °C
  • Up to 3,500° C: 0.4 % of Measured Value in °C