Yodify Product Library
Add the RS-1/RS-2 Recovery / Reinjection System to your store or catalog
Book Your Demo and See How
or create your store
RS-1/RS-2 Recovery / Reinjection System
Brand: Meter EngineersThe RS-1/2 can be incorporated into any sampling or slipstream process unit. It is designed to reinject the product used by the unit, eliminating unwanted product in the station sump system.
The RS-1/2 Recovery/Re-Injection System consists of a 15-gallon stainless steel tank, 4 level stainless steel float system, 2 HP or 3 HP explosion proof motor, reduction gear box, positive displacement pump, and a programmable logic controller (PLC). The RS-1/2 Recovery/Re-Injection System has 3 modes of operation.
Features- NORMAL CYCLE: With the selector switch in the NORMAL position, the product enters the recovery tank from the flasher as it is running. The product will rise in the tank until it reaches the 9.4-gallon level float switch (LS1, high level). The motor/pump will start injecting products into the pipeline until the product level decreases below the lowest level float switch. If the Process Unit should stop, then the RS-1/2 can be interconnected to stop also. When the unit resumes operation, the RS-1/2 will start injecting again once the product level has risen above the LS2 float level switch. The tank will be pumped empty in approximately 5 minutes
- FAST CYCLE: In the fast cycle mode, (selector switch in the FAST position) the pump will start when the product level reaches the 3.7-gallon lowest level float switch. The tank will be pumped empty in approximately 2 minutes
- MANUAL CYCLE: In the manual cycle mode, (selector switch in the MANUAL position) the pump unit will run if the product level is above the lowest level float switch
- ALARM CONDITIONS: The RS-1/2 Recovery System has alarm outputs to alert station personnel of an abnormal or malfunction condition and PLC protection to prevent tank overflow or pump/motor damage
Specifications
Brand
Pump Discharge Connection
- 1/2 Swagelok Stainless Steel Tubing/Hose
Pump Inlet Filtration
- 230 Micron T Type Filter
Discharge Valve Cracking Pressure
- 100 psig
Discharge Valve Pressure
- 1,225 psig
- 2,225 psig
Frame
- 184 C Face
- 215 C Face
Motor HP
- 2
- 3
Motor RPM
- 1,725
Helical Gear Ratio
- 2.7:1
- 4.13:1
Recovery Tank Capacity
- 15 Gal
Materials of Construction
- 12 Gauge: 304 Stainless Steel
Pump GPM
- 1.85
- 4
Pump Output Pressure
- Maximum 1,200 psig
- Maximum 2,200 psig
Input Voltage
- 230 Vac Single Phase (With Neutral for 115 Vac Control)
- 208-230 Vac Single Phase (With Neutral for 115 Vac Control)
Input Current
- 11.6 A
- 15 A
Customer Status Input
- Remote Pump Run Command
Customer Status Output
- High-High Tank Level (2 Form C, 10 Amp Dry Contacts)
- Alarm/Malfunction (2 Form C 10 Amp Dry Contacts)
- Pump On (PLC 2 Amp Contact, Common to Outputs 0-3)
- High Tank Level (PLC 2 Amp Contact, Common to Outputs 0-3)