MINIVAP VP Vision is a highly versatile portable vapor pressure tester that features best-in-class precision and a pressure range of 0-2000 kPa (290 psi).

It is the first analyzer that demonstrates excellence in engineering by earning certificates for robustness and durability.

Based on Grabner´s cutting-edge Cockpit™ technology, the instrument offers unmatched networking capabilities and enables worldwide access to analyzers.

Engineered for Excellence

MINIVAP VP Vision measures gasoline, jet fuel, crude oil, LPG and solvents. Long-term testing has demonstrated an unmatched repeatability.

The newly developed Grabner 2D-Correction™ (273 points) and exact piston positioning guarantee that accurate and precise results are received over the full measuring range.

MINIVAP VP Vision incorporates Grabner´s Sampling Pro™ valve design, which during ruggedness tests proved to be the best-in- class piston based design for minimizing cross contamination between various sample types.

Simplicity and Flexibility

The MINIVAP VP Vision uniquely combines ease of use with flexibility. A modern, app-like user interface makes it easy to select, start and follow measurements directly on the industry- proven 10” touch screen.

With just a few clicks, measuring templates can be created and customized methods can be added. In addition, Grabner´s Cockpit™ PC software offers lab managers the utmost in flexibility.

The software combines measurement results from multiple locations.

Access. Anywhere. Anytime

With the Cockpit™ PC software multiple instruments are automatically recognized and devices all around the world can be configured, monitored, diagnosed, serviced and upgraded from one central lab.

The software can be accessed through a secure VPN tunnel, allowing for true mobile access to instruments from any place at any time. A unique call home function facilitates easy uplink to our well trained support team.

Durability and Robustness

The MINIVAP VP Vision is the first vapor pressure tester certified to work in cold, hot and damp heat climate. It has demonstrated an ability to withstand vibrations and heavy shocks coming from any direction.

This instrument is ideal for use in mobile laboratories, in military applications or in harsh environments.

Most Versatile, Most Complete

MINIVAP VP Vision comes fully configured to run all major vapor pressure methods. Every analyzer incorporates an integrated shaker for Crude Oil with adjustable speed.

Highest Accuracy - Lowest Limit: Low Volatility Model MINIVAP VPL Vision

While the standard VP model is designed to sustain pressures up to 20 bar, some applications require increased measurement sensitivity for samples with a very low volatility.

These applications include e.g. the measurement of Diesel, Oils or Flavors & Fragrances. The MINIVAP VPL Vision model is designed for low volatility measurements with a pressure range of 0.5 to 110 kPa (.07 to 16 psi).

It shows a measuring repeatability of ±0.11 kPa (0.01 psi) and reproducibility of  ±0.20 kPa (0.02 psi) for low volatile samples.

Direct / Indirect Determination of the Absolute Vapor Pressure ("VOC-Methods")

The model MINIVAP VPL Vision was developed to automate the manual ASTM D2879 Standard Test Method for Vapor Pressure by Isoteniscope for low volatile samples, which is used by the chemical industry.

The instrument incorporates a direct and an extrapolated "VOC" method for absolute vapor pressure measurement of single- and multi-component samples.

The direct "VOC"-method is a static method for determining the absolute vapor pressure required for safety data sheets.

The indirect method additionally allows to extrapolate to extremely low pressures or to temperatures that exceed the instruments temperature range (-100°C to +300°C).

Both methods yield results comparable to the static ASTM D2879 Isoteniscope method, but do not require sample evacuation prior to testing.

Based on the GRABNER Triple Expansion Method, air/gases are removed automatically from the measurement result and the sample composition is maintained during measurements.

"VOC"-methods  are available in both the MINIVAP VPL and the VP Vision analyzer. Because of a better sensitivity for low volatile samples, the precision of the VPL Vision is significantly better in the pressure range.

Principle

The sample is contained in a 10 mL syringe or in a sample container for direct sampling. The automatic sample introduction and the volume adjustments are made by a piston with an integrated pressure transducer. 

The measuring chamber with a total volume of 5 mL is automatically rinsed and filled with 1 mL for the measuring process.

After closing the valve driven by the valve motor, the volume expansion to 5 mL (with the sample under vacuum condition) is obtained by a further stroke of the piston.

The temperature of the measuring cell is controlled with a high-power thermoelectric module and measured with a precision Platinum RTD sensor.

After the sample introduction and the volume expansion, the test temperature is adjusted. After the equilibrium time, the measurement of the dissolved air is completed. Test results of DVPE, ASVP, Pgas and Pabs are displayed and printed.

Automatic piston lubrication is processed with every piston stroke.
Features
  • Unmatched precision for the VP measurement of gasoline and aviation fuels, crude oil, LPG, hydrocarbon solvents and chemical compounds
  • Pressure range from 0 - 2000 kPa (VPL Vision: 0.5 - 110 kPa)
  • Unique 2-D Correction™ to ensure highest measuring precision over the full testing range
  • Integrated shaker for Crude Oil with adjustable speed
  • Smallest sample size: 1 ml w/o rinsing
  • Fast measurements: Results in 5 minutes
  • Automatic sample introduction and cell cleaning through piston-based design
  • No vacuum pump or sample preparation necessary!
  • Sampling Pro™ valve design, best in class for minimizing sample cross contamination
  • Thermoelectric temperature control - no external cooling necessary
  • Maintenance free through central lubrication system; rapid oil refill w/o disassembling
  • Cleanable, reusable filter assembly
  • 10“ industry-proven full color touchscreen
  • Modern, app-like user interface with big buttons; works also with gloves - no stylus required!
  • Customizable measurement templates
  • Unique PDF results sheet with pressure and temperature graphics
  • Fast Mode™ Method: Runs D5191 and D5188 in combination
  • Full calibration history and calibration backup function
  • Certified for use in cold, dry and damp heat environment (EN60068-2-1, EN 600068-2-78, EN 60068-2-14)
  • Shockproof and vibration-resistant portable design (EN 60068-2-6, EN 60068-2-27)
  • Ideal for laboratory and field use
  • 2 years warranty

Specifications

Methods Included in MINIVAP VP Vision

  • ASTM D6378 - Vapor Pressure of Gasoline and Petrochemicals (VPx): Grabner's ”Triple Expansion Method” with determination of the dissolved air in the sample. No cooling and air Saturation required!
  • ASTM D5191 - DVPE Dry Vapor Pressure Equivalent (w/ EPA and CARB correlation formulas): Standard ”Mini-Method” measured against vacuum and a correlation formula for the calculation of the DVP. Requires sample preparation, including cooling of the sample to 0° C (32° F) and triple air saturation prior to the measurement.
  • ASTM D6377 - Vapor Pressure of Crude Oil (VPCRx): ”Single-Expansion Method” for vapor pressure of Crude Oil developed by GRABNER INSTRUMENTS. Better precision than classical ASTM D323 RVP method, ASTM correlation formula to D323 available. Does not require sample preparation: Saves time, increases precision and eliminates operator bias.
  • ASTM D6897 - Vapor Pressure of LPG up to 2000 kPa: Easy, quick, fully automatic and accurate measurement of liquefied petroleum gas. Replaces the manual bomb method ASTM D1267. ASTM D6897 eliminates manual operation and cleaning and minimizes sample waste. Yields results in excellent correlation with ASTM D1267, but with a highly improved precision.
  • ASTM D5188 - V/L-Ratio (TV/L): Determines V/L ratio of non-viscous liquids including hydrocarbons like gasoline, solvents and other highly volatile compounds. Instrument performs fully automatically, providing results in minutes. No additional equipment is required.
  • Fast Mode™ - ASTM D5188 & D5191 Fast Mode™ Method: Runs ASTM D5188 and D5191 directly after each other.
  • EN 13016 - 1 - Air Saturated Vapor Pressure
  • EN 13016 - 2 - Absolute Vapor Pressure
  • IP 394, 409, 481 - IP Methods for gasoline and crude oil
  • JIS K2258-2 - Japanese standard method for gasoline
  • SHT 0769 - Chinese standard method for gasoline
  • SHT 0794 - Chinese standard test method for Vapor Pressure of Petroleum Products (Mini Method)
  • SNT 2932 - Determination of Vapor Pressure of Chemicals - Triple Expansion Method
  • GOST 52340 - Russian / CIS standard method for crude oils
  • VOC Methods - Direct and Indirect Low Volatility Methods: Static methods for determining the absolute vapor pressure required for safety data sheets. Both methods yield results comparable to the static ASTM D2879 Isoteniscope method, but do not require sample evacuation prior to testing.
  • TVP - True Vapor Pressure TVP of Crude Oils (FW 2.0)
  • Custom - Customized Single and Triple Expansion Methods

MiniVap VP/VPL Vision Vapor Pressure Tester Complies with

  • ASTM D6378 - Vapor Pressure of Gasoline (VPx)
  • ASTM D5191 (Dry Vapor Pressure Equivalent)
  • ASTM D6377 - Vapor Pressure of Crude Oil (VPCRx)
  • ASTM D6897 - Vapor Pressure of LPG up to 2000 kPa
  • ASTM D5188 - (V/L-Ratio)
  • EN 13016 - 1 (Air Saturated Vapor Pressure)
  • EN 13016 - 2 (Absolute Vapor Pressure)
  • IP 394 & 409 & 481
  • JIS K2258-2, SHT 0769, GOST 52340
  • US EPA approved Grabner test method for highest accuracy

Excellent Correlation To

  • ASTM specified correlation to D323 (Wet Reid)
  • ASTM specified correlation to D4953 (Dry Reid)
  • ASTM D5482 (Mini-Method, atmospheric)
  • ASTM D1267 (LPG)
  • ASTM D2879 (Isoteniscope method)
  • REACH static vapor pressure test method

Other Available Methods

  • ASTM D5188 & D5191 Fast Mode™ method
  • TVP - True Vapor Pressure of Crude Oils (FW 2.0)
  • Direct and Indirect VOC Low Volatility Methods
  • Custom Single and Triple Expansion Methods

Relevant Fuel Specifications

  • ASTM D4814 (Automotive Gasoline)
  • EN 228 (Automotive Gasoline)
  • ASTM D910 (Leaded Aviation Gasoline)
  • ASTM D6227 (Unleaded Aviation Gasoline)
  • ASTM D1655 (Aviation Turbine Fuels)
  • ASTM D1835 (LPG)

Cockpit™ PC Software

  • Includes license for Grabner Cockpit™ PC software. For automatic instrument recognition, worldwide analyzer uplink and centralized results and statistics management. Enables remote user management and user training, remote device configuration and software update, remote diagnostics, online support and calibration checks.

Options / Accessories

  • Crude oil package for MINIVAP VP Vision available. Due to the instrument´s extended pressure range no pressure regulator is required for filling typical pressurized samples! A dedicated Pipeline Package is available for filling pressures > 2000 kPa

Temperature Range

  • Measured: 0° to 120° C (32° to 248° F), User Programmable
  • Extrapolated: -100° to 300° C (-148° to 572° F)

Temperature Stability

  • ± 0.01° C (0.018° F)

Temperature Profiles

  • Single temperature, multipoint, curve, extrapolation

Pressure Range

  • VP Vision: 0 to 2000 kPa (0 to 290 psi)
  • VPL Vision: 0.5 to 110 kPa (.07 to 16 psi)

Pressure Resolution

  • 0.01 kPa (0.0014 psi)

Precision VP Vision

  • Repeatability: ± 0.13 kPa (0.01 psi)
  • Reproducibility: ± 0.20 kPa (0.02 psi)

Precision VPL Vision

  • Repeatability: ± 0.11 kPa (0.01 psi)
  • Reproducibility: ± 0.20 (0.02 psi)

Vapor-Liquid Ratio

  • 0.02/1 to 100/1, depending on method

Sample Volume

  • 1 mL (2.2 mL per rinsing)

Measurement Time

  • ~ 5 min., depending on method

Results Database

  • > 100,000 detailed results with graphics stored on the instrument

Results Download

  • csv, PDF with graphics

Instrument OS

  • Microsoft Windows®

Instrument Electronics

  • Intel Industry PC
  • 24-bit ADC
  • 10” Industrial Full Color Touchscreen

Instrument Languages

  • en / de / fr / es / pt / it / ru / ar / zh / ja, customizable

Interfaces

  • 2x USB, 2x LAN (1x DVI-I, 1x RS-232)

Operation / Environmental Condition

  • 0 - 50° C, 93 % r.H. Non-Condensing according to EN 60068-2-1, EN 60068-2-78, EN 60068-2-1

Shockproof

  • acc. to EN 60068-2-6 (req. (IEC 60721-3-2, Class 2M2)

Vibration Resistant

  • acc. to EN 60068-2-27 (req. IEC 60721-3-2, Class 2M2)

Power Requirements

  • 100-264 Vac, 45-63 Hz, 80 W (Switching Power Supply)

Field Application

  • DC/AC Power Converter 12 V

W x H x D

  • 293 x 390 x 280 mm (10.5 x 15.4 x 11 in.)

Weight

  • 10.5 kg (28 lb)