Yodify Product Library
Instantly add the AQUATRAN 3 WVTR Analyzer and 50,000+ more product series to your store or catalog  
Book Your Demo and See How
or create your store

AQUATRAN 3 WVTR Analyzer

Brand: MOCON

The AQUATRAN 3 analyzer is the industries most trusted WVTR instrument for high to ultrahigh-level barriers because it can measure each molecule of water vapor entering the sensor.

The analyzer is easy to use and offer the lowest detection levels available in the market.

It features 2 independent cells with changeable horizontal test cartridges that allow a wide variety of sample sizes and types to be easily and accurately tested.

Highest Accuracy and Repeatability
  • Patented AQUATRACE® sensor is the most trusted absolute Coulometric sensor on market that never need calibration
  • Ultra-Low detection level down to 0.00005 g/(m² x day)
  • Fully automated temperature, flow and RH controls simplify testing and provide unparalleled repeatability
  • TruSeal gas flushed perimeter sealing system reduces potential environmental water vapor ingress providing accurate results
Demanding Applications
  • OLED flexible displays and electronics applications that require ultra-high barriers to moisture
  • High moisture barrier packages for Pharmaceutical industry

The AQUATRAN 3 analyzer can test the Water Vapor Transmission Rate (WVTR) on both films and packages from high to ultra-high barriers.

It uses the MOCON’s patented long life AQUATRACE WVTR sensor which has a linear output throughout the entire measurable range.

This guarantees highly accurate and repeatable results throughout it’s a wide detection range from 0.00005 to 5 g/(m² x day).

The upper detection limit can be extended with the use the reduced area film test cartridge (factor x9), or various size masking.

The analyzer has industry leading features such as removable and interchangeable horizontal test cartridges, easy to use touch screen operator interface, and fully automated testing providing higher throughput in the lab.

For more than 15 years, MOCON’s AQUATRAN series have been the most trusted and longest lasting on the market.

For complex multi-layered high barriers or sensitive electronics and panels, the AQUATRAN 3 is the right choice for advanced WVTR testing.

The AQUATRAN 3 analyzer is the industries most trusted WVTR testing instrument for high to ultrahigh-level barriers.
Features
  • Removable Cartridges
    • Easy sample prep on the benchtop
    • One button release and loading
    • Pneumatic clamping provides more repeatable results
    • Interchangeable cartridge options extend the range and flexibility of the analyzer without tools while maintaining arcuate results
    • Cartridge options include:
      • Reduced area to extend testing range without masks
      • Improved accuracy testing of paper-based barriers
      • Adaptors for remote testing of packages or extreme conditions
      • Custom designs for unique testing requirements
  • TruSeal®
    • Eliminate Individual Zero
    • Reduced testing time (increase throughput)
    • More repeatable results
  • Automated Control Features
    • Flow, Temp, & RH control
    • Test Process Development and Recommendations
    • Programmable Test Sequencing
    • Test report printing and export
    • Sensor Protection
  • Touchscreen Interface
    • Intuitive automated operation requires less training
    • Built in multi-level user management and data security
    • Event log & trouble shooting guide
    • Save on valuable lab space by eliminating need for PC
  • AQUATRACE Sensor
    • Ultra-low level of detection down to 5 x 10⁵ g/(m² x day)
    • Longer sensor life than others on the market
    • Accurate and repeatable results
    • Most trusted P2O5 sensor that fully complies with ASTM F3299 and ISO 15106-3
  • Warranty
    • Full 100% parts and workmanship warranty for 12 months

Specifications

Brand

Temperature Control Range

  • 5° C to 50° C ± 0.2° C at 100 % RH
  • 10° C to 40° C ± 0.2° C at 5 to 90 % RH

Humidity Control, Film Cell, Test Gas

  • 100 % and 5 % to 90 % RH ± 3 RH

RH Film Cell-to-Cell Uniformity

  • ± 3 RH

Test Range, Film, Standard 50 cm² Sample

  • 0.05 to 5000 mg/(m² • day)
  • 0.0032 to 322.6 mg/(100 in² • day)

Test Range, Package

  • 1.0 to 2000 cc/(m² x day)
  • 0.065 to 129 cc/(in² x day)

Resolution, Film

  • 0.01 mg/(m² • day)
  • 0.00065 mg/(100 in² • day)

Resolution, Package

  • 0.00005 mg/(pkg • day)

Repeatability, Film

  • ± 0.050 mg/(m² • day)
  • ± 0.0032 mg/(100 in² • day) or 1 % of value, whichever is greater

Repeatability, Package

  • 0.00025 mg/(pkg • day) or 1 % of value, whichever is greater

Film Size

  • 4” x 4” Standard
  • 2” x 2” optional

Film Thickness

  • Up to 120 Mil

Film Test Area

  • 50 cm² Standard, Option to 5.6 cm²

Carrier Gas

  • Nitrogen

Dimensions & Weight

  • 15.5” H x 12” W x 23” D (39.4 cm x 30.4 cm x 58.0 cm)
  • 95 lbs (43.1 kg)

Electrical Requirements

  • Voltage: 100-240 Vac 50/60 Hz
  • Maximum Power Draw: 700 VA

Laboratory Requirements

  • Temperature - Operation: 22° C ± 2° C | Storage: 10° C to 30° C
  • Humidity - Operation: 20 % to 80 % RH (Non-Condensing) | Storage: 5 % to 85 % RH (Non-Condensing)

Gas Supply Requirements

  • Carrier Gas: Gas Composition - Nitrogen (99.9999 % N₂ or better) | Supply Pressure, Nominal - 29 psi, (2.0 bar), (200 kPa)

Connectivity

  • Remote Access and Control (requires optional Perm-Net Light software)
  • Standard Ethernet port (100T)
  • Dual USB 2.0 ports (for connection of keyboard, mouse or memory devices)

Compliance Standards

  • This product is UL and CSA listed using the ETL mark from Intertek Group plc. and is certified to conform to CE
  • Conforms to EU Directive 2011/65/EU RoHS Compliance
  • Conforms to the following internationally recognized safety standards:  IEC 61010-1:2010 Third Edition | UL 61010-1:2012 Third Edition | CAN/CSA C22.2 No. 61010-1:2012 Third Edition
  • Conforms to the following internationally recognized EMC standards: EN 61326-1:2013 | EN 61000-3-2:2006, A1:2009, A2:2009 | EN 61000-3-3:2013

Cartridges & Options

  • Reduced Area Cartridge
  • Custom Engineered Test Cartridges
  • Package Testing Adaptor

Accessories

  • Consumables: Cert Films 2-4, Masks

Service & Support Options

  • Basic Preventative Maintenance Plan
  • Plus Preventative Maintenance Plan
  • IQ/OQ Documentation & Validation

Software

  • PermWare Data Collection, Data Management and Instrument Status Dashboard
  • Remote Viewing Software from a PC - PermNet Lite
  • 21 CFR Part 11 User and Data Security

Test Standard Compliance

  • JIS K7129-3
  • ISO 15106-3
  • GB/T 21529-2008

Test Methodology

  • Following ASTM D3985
  • Standard Test Method for Water Vapor Transmission Rate Through Plastic Film and Sheeting Using and Electrolytic Detection Sensor (Coulometric P2O5 Sensor)

Summary of Test Method

  • A dry chamber is separated from a wet chamber of known temperature and humidity by the barrier material to be tested. The dry chamber and the wet chamber make up a test cell in which the test film is sealed. Water vapor permeating through the film mixes with the dry carrier gas in the dry chamber and is carried to an electrolytic sensor. The carrier gas is passed through the sensor where water vapor it holds is absorbed by the phosphorous pentoxide (P2O5). Direct current, applied to the electrodes of the sensor, dissociates the water into hydrogen and oxygen. Two electrons are required to electrolyze each water molecule, and the current in the cell represents the number of molecules dissociated per unit time.

  • Packaging Films
    • Monolayer
    • Multi-layer
    • Coated Films
    • Coated Paper/Paperboard
  • Specialty Films
    • Solar Back Sheets
  • Packages
    • Medical Packages
    • Bottles/Closures
  • Encapsulation
    • Solar Panels
    • Windows
    • OLED Devices
    • Other Electrical Applications
  • Blisters
    • Medical
    • Optical
  • Seals
    • O-Rings
    • Gaskets
Instantly populate your store or catalog 
CREATE YOUR SITE
or book a demo with the Yodify Team
show more