Yodify Product Library
Instantly add the RT4 RTD Assembly and 50,000+ more product series to your store or catalog  
Book Your Demo and See How
or create your store

  • Probe Style:
    • General Purpose
    • Electrically Isolated
    • Tip Sensitive
    • Bayonet Style
    • Tip Sensitive & Electrically Isolated
    • Bayonet & Tip Sensitive
  • Element:
    • 100Ω Platinum
    • 120Ω Nickel
    • 10Ω Copper
    • Single / Dual Elements
  • Number of Lead wires: 2 to 4 (Compensated Loop w/ 4)
  • Probe Diameter: 1.25 mm to 2.5 mm (1/8" to 1/4")
  • Lead Options:
    • Teflon / Armored Teflon
    • Fiberglass / Armored Fiberglass
    • Standard 6" TFE
  • Termination:
    • Bare Ended Leads
    • Standard Connector
    • Mini Connector
    • Mini Head
  • Process Fitting:
    • Compression Fitting
    • Adjustable Spring
    • Fixed Hex Bushing
    • Spring Loaded Transmitter Bushing
    • Oil Seal Hex Bushing
  • Temperature Rating:
  • Low Temp 204°C (399°F) Max.
  • High Temp 482°C (899°F) Max.
  • High Temp & Vibration 850°C (1,562°F)

1 - 12 of 18 Part Numbers
RT4-GP-A-D-3-14-8-TE-36-BE-X-X-LT
RT4-GP-A-D-3-14-8-TE-36-BE-X-X-LT
AIRCOM RTD Sensor Probe, General Purpose, PT100, Dual Element, 3-Wire, 1/4" OD, 8" Probe Length, 36" Teflon Leads, Bare Ended, No Fitting, -50 to 260°C
RT4-GP-A-S-3-14-10-TE-36-BE-FS-12-HT
RT4-GP-A-S-3-14-10-TE-36-BE-FS-12-HT
AIRCOM RTD Sensor Probe, General Purpose, PT100, Single Element, 3-Wire, 1/4" OD, 10" Probe Length, 36" Teflon Leads, Bare Ended, Fixed Bushing, 1/2" NPT x 1/2" NPT, -50 to 482°C
RT4-GP-A-S-3-14-2.5-TE-6-BE-FS-12-LT
RT4-GP-A-S-3-14-2.5-TE-6-BE-FS-12-LT
AIRCOM RTD Sensor Probe, General Purpose, PT100, Single Element, 3-Wire, 1/4" OD, 2.5" Probe Length, 6" Teflon Leads, Bare Ended, Fixed Bushing, 1/2" NPT x 1/2" NPT, -50 to 260°C
  • RT4: RTD Probe
  • GP: General Purpose Style Probe (Style of probe-not the rating) 
  • A: 100 Ohm Pt.385 Element
  • S: Single Element
  • 3: 3 Wire
  • 14: 1/4" Probe OD 
  • 2.5: 2.5" Probe Length
  • T: Teflon Lead Wires
  • 6: 6" Lead Wires
  • BE: Bare-Ended Leads
  • FS: 1/2" x 1/2" Fixed Bushing (Class I, Div II when installed with approved enclosure)
  • LT: Low Temperature (204°C Maximum)
RT4-GP-A-S-3-14-20-TE-6-SL-X-X-VT
RT4-GP-A-S-3-14-20-TE-6-SL-X-X-VT
AIRCOM RTD Sensor Probe, General Purpose, PT100, Single Element, 3-Wire, 1/4" OD, 20" Probe Length, 6" Teflon Leads, Spade Lugs, No Fitting, -50 to 482°C (Vibration Construction)
RT4-GP-A-S-3-14-3-AT-180-BE-CF-12-LT
RT4-GP-A-S-3-14-3-AT-180-BE-CF-12-LT
AIRCOM RTD Sensor Probe, General Purpose, PT100, Single Element, 3-Wire, 1/4" OD, 3" Probe Length, 18" Flex Armor Over Teflon Leads (260°C), Bare Ended, Compression Fitting (SST Ferrule), 1/2" NPT, -50 to 260°C
RTD Probe, PT100, Single, 3 Wire, 1/4"OD, 3" "L", 180" Armored Teflon, 1/2"NPT Comp Fitting, LT
RT4-GP-A-S-3-14-3-AT-180-BE-TX-12-LT
RT4-GP-A-S-3-14-3-AT-180-BE-TX-12-LT
AIRCOM RTD Sensor Probe, General Purpose, PT100, Single Element, 3-Wire, 1/4" OD, 3" Probe Length, 180" Flex Armor Over Teflon Leads (260°C), Bare Ended, Spring Loaded Bushing, 1/2" NPT x 1/2" NPT, -50 to 260°C
  • RT4: Custom Sheathed RTD
  • GP: General Purpose
  • A: 100U Platinum 385 ± 0.1%
  • S: Single Element
  • 3: 3-Wire
  • 14: 1/4" O.D. Probe Diameter
  • 3: Length of Probe in inches (L)
  • AT: Armored Teflon Leads
  • 180: Length of Leads in inches (A)
  • BE: Bare Ended Leads
  • TX: Spring Loaded Transmitter Bushing
  • 1/2: NPT Size of Bushing
  • LT: Low Temp (204 C Max)
RT4-GP-A-S-3-14-36-TE-6-BE-X-X-VT
RT4-GP-A-S-3-14-36-TE-6-BE-X-X-VT
AIRCOM RTD Sensor Probe, General Purpose, PT100, Single Element, 3-Wire, 1/4" OD, 36" Probe Length, 6" Teflon Leads, Bare Ended, No Fitting, -50 to 482°C (Vibration Construction)
RT4-GP-A-S-3-14-4.5-TE-6-BE-X-X-VT
RT4-GP-A-S-3-14-4.5-TE-6-BE-X-X-VT
RT4-GP-A-S-3-14-5.5-TE-6-BE-X-X-VT
RT4-GP-A-S-3-14-5.5-TE-6-BE-X-X-VT
AIRCOM RTD Sensor Probe, General Purpose, PT100, Single Element, 3-Wire, 1/4" OD, 5.5" Probe Length, 6" Teflon Leads, Bare Ended, No Fitting, -50 to 482°C (Vibration Construction)
RT4-GP-A-S-3-14-6-AT-240-BE-X-X-VT
RT4-GP-A-S-3-14-6-AT-240-BE-X-X-VT
AIRCOM RTD Sensor Probe, General Purpose, PT100, Single Element, 3-Wire, 1/4" OD, 6" Probe Length, 240" Flex Armor Over Teflon Leads (260°C), Bare Ended, No Fitting, -50 to 482°C (Vibration Construction)
AIRCOM RTD Probe, 100ohmPt, 3Wire, 1/4" OD, 6" L, 240" Armoured Teflon Leads, Bare Ended, VT (850°C)
RT4-GP-A-S-3-14-6-T-6-BE-FS-12-LT
RT4-GP-A-S-3-14-6-T-6-BE-FS-12-LT
RT4-GP-A-S-3-14-6.5-TE-6-SL-X-X-VT
RT4-GP-A-S-3-14-6.5-TE-6-SL-X-X-VT
AIRCOM RTD Sensor Probe, General Purpose, PT100, Single Element, 3-Wire, 1/4" OD, 6.5" Probe Length, 6" Teflon Leads, Spade Lugs, No Fitting, -50 to 482°C (Vibration Construction)
1 - 12 of 18 Part Numbers

Specifications

Element

  • 10 ohms Copper 427 0.039 ohm/°C
  • 100 ohms Platinum 385 ± 0.01 %
  • 100 ohms Platinum 385 ± 0.1 %
  • 100 ohms Platinum 392 ± 0.1 %
  • 120 ohms Nickel 627 0.806 ohm/°C
  • Dual Elements
  • Single Element

Materials of Construction

  • 316 Stainless Steel

NPT Connection

  • 1” NPT Male
  • 1/2” NPT Male
  • 1/4” NPT Male
  • 1/8” NPT Male (with Standard Adapter)
  • 1-1/2” NPT Male
  • 3/4” NPT Male

Process Fitting Details

  • Adjustable Spring
  • Compression Fitting (1/4”, 1/2”, 3/4”, 1”, 1-1/2” NPT Male)
  • Fixed Hex Bushing (1/4”, 1/2”, 3/4”, 1”, 1-1/2” NPT Male)
  • Oil Seal Hex Bushing (1/4”, 1/2”, 3/4”, 1”, 1-1/2” NPT Male)
  • Spring Loaded Transmiter Bushing (1/4”, 1/2”, 3/4”, 1”, 1-1/2” NPT Male)

Process Temperature

  • -200° to 850° C (-328° to 1,562° F)

Sensor, Probe Diameter

  • 0.215” O.D.
  • 1/4” O.D.
  • 1/8” O.D.
  • 3/16” O.D.

UNF/UNC Connection

  • 3/8” NF Male (with Standard Adapter)

Version / Leadwires

  • 2-Wire
  • 3-Wire
  • 4-Wire
  • 4-Wire Compensated Loop
Instantly populate your store or catalog 
CREATE YOUR SITE
or book a demo with the Yodify Team
show more