Yodify Product Library
Instantly add the CI 61-CI 98 Contactor and 50,000+ more product series to your store or catalog
Book Your Demo and See How
or create your store
CI 61-CI 98 Contactor
Brand: DanfossContactors CI 61, CI 73, CI 86 and CI 98 switch powers of up to 30 kW, 37 kW, 45 kW and 55 kW respectively under 3 x 380 Vac -3 loads.
Accessories include a wide selection of auxiliary contacts, mechanical interlocks and RC elements. Auxiliary contacts for mounting on the side or top are available.
The auxiliary contacts have force-actuated contacts and can form part of safety switching.
1 - 12 of 16 Part Numbers
037H304013
- Type - CI 98
- Coil Voltages - 24 V, 50/60 Hz
037H304023
- Type - CI 98
- Coil Voltages - 110 V, 50/60 Hz
037H304032
- Type - CI 98
- Coil Voltages - 220-230 V, 50 / 60
037H304039
- Type - CI 98
- Coil Voltages - 380-400 V, 50/60 Hz
037H306113
- Type - CI 61
- Coil Voltages - 24 V, 50/60 Hz
037H306123
- Type - CI 61
- Coil Voltages - 110 V, 50/60 Hz
037H306132
- Type - CI 61
- Coil Voltages - 220-230 V, 50 / 60
037H306139
- Type - CI 61
- Coil Voltages - 380-400 V, 50/60 Hz
037H306213
- Type - CI 73
- Coil Voltages - 24 V, 50/60 Hz
037H306223
- Type - CI 73
- Coil Voltages - 110 V, 50/60 Hz
037H306232
- Type - CI 73
- Coil Voltages - 220-230 V, 50 / 60
037H306239
- Type - CI 73
- Coil Voltages - 380-400 V, 50/60 Hz
1 - 12 of 16 Part Numbers
Specifications
Brand
Ambient Temperature Range
- -50° to 60° C (-58° to 140° F)
Approvals & Certifications
- CSA
- IEC 947, EN 60947
- UL
Approvals & Certifications
- EN 609
Compensated Temperature
- -5° to 40° C (23° to 104° F)
Consumption
- 4.5 W - Coil Consumption
- 9 W - Coil Consumption
Cooling Time
- 20 minutes - Min.
Current
- 10-4,700 KA - Max.
- 60-130 A
- 60-90 A - Max.
- 90 A
Electrical Connectors
- DIN 40046
- DIN 50016
- Screw Terminal
- Single & Multi Core AWG
- Terminal Box
Load
- 220-240 V, 50/60 Hz
- 380-690 V, 50/60 Hz
- Minimum: 24 V, 10 mA
Load Impedance
- 0.6 megaohms - Typical Impedance Per Pole
- 0.9 megaohms - Typical Impedance Per Pole
Operating Temperature
- -25° to 115° C (-13° to 239° F)
Operation
- 10,000,000 - Mechanical Life Operations
- 100,000 - Electrical Life AC-3 Operations
- 30 - Max.
- 300 - Duty Cycles Per Hour AC-3 Load Operations
Power
- 14.2-26 W - Total Power Loss
- 16 VA - Holding-Power
- 16 W - Inrush Power
- 18.5-155 KW
- 200 VA - Inrush Power
- 4.5 W - Holding-Power
- 9.7-19.5 W - Power Loss at 3-Poles
Shock
- 9 G, 7.5 milliseconds
Storage Temperature
- -55° to 80° C (-67° to 176° F)
Supply Voltage
- 8 kV - Pulse Voltage
Torque
- 1 to 6 Nm (8.85 to 53.1 In/Lbs)
Transfer Time
- 10 seconds
Turn-Off Time
- 10 to 60 milliseconds - Break Time
Turn-On Time
- 18.5 to 30 milliseconds - Make Time
Vibration
- 2 G at 200 Hz