340 BN/MB BTU Energy Transmitter
Brand: Badger MeterThe 340 BN/MB BTU Energy Transmitter is an economical, compact device for sub-metering applications using the BACnet or Modbus® communications protocol.
An economical, compact device for sub-metering applications.
Calculates thermal energy using the signal from a flow sensor installed in a hydronic heating or chilled water system, and the signals from two 10 kΩ temperature thermistors, 100 Ω RTDs or 1000 Ω RTDs installed in the system’s inlet and outlet points.
Features- On-board microcontroller and circuitry make precise measurements and produce accurate, drift-free outputs
- Calibration information for the flow sensor type and pipe size may be preselected or entered by the user in the field
- Calculates thermal energy using the signal from a flow sensor installed in a hydronic heating or chilled water system
- Compact cast epoxy body
Specifications
Brand
Power Supply Options
- Power Supply: 12…24 VAC | 12…35 VDC
- Current Draw: 115 mA max. at 12 VDC
Pulse Type Sensors - Signal Amplitude
- 2.5 VDC Threshold
Pulse Type Sensors - Signal Limits
- Vin < 12 V (DC or AC peak)
Pulse Type Sensors - Frequency Range
- 4…1000 Hz
Pulse Type Sensors - Pull-up
- 15 VDC @ 2 kΩ Source Impedance
Sine Wave Sensors - Signal Amplitude
- 30 mV p-p Threshold
Sine Wave Sensors - Signal Limits
- Vin < 12 V (DC or AC peak)
Sine Wave Sensors - Frequency
- 4…1000 Hz
Power Out Terminal
- 15 VDC ± 1 VDC @ 500 Ω Source Impedance
Temperature Sensor (2 of same type Required) Input
- 10 kΩ Thermistor, 2 Wire, Type II, 10 kΩ @ 25°C (77°F)
- 100 Ω Platinum RTD, DIN Calibration Curve, conforms to IEC-751 Standard
- 1000 Ω Platinum RTD, DIN Calibration Curve, conforms to IEC-751 Standard
- Calibration range of Measurement 0…150°C (32…302°F)
Communication Port
- RS-485 with Termination, Pull-up and Pull-down Jumpers
Pulse Output
- Isolated Solid-State Switch in any Standard or Custom Total Units
- Adjustable 50 ms to 1.0 second pulse output width in 50 ms increments
- Maximum Sinking Current: 100 mA @ 36 VDC
Temperature
- Operating: 32...158 °F (0...70 °C)
- Storage: –40…185 °F (-40...85 °C)
Weight
- 4.8 oz with Connector Headers Installed
Sensor Calibration
- Badger Meter: Use K and offset values provided in sensor manual
- Other Sensors: Check with respected manufacturer of flow sensor and with factory
Unit of Measure - Flow Measurement Rate
- Rate: gpm, gph, l/sec, l/min, l/hr, ft³/sec, ft³/min, ft³/hr, m³/sec, m³/min, m³/hr
- Total: Gallons, Gallons X 100, Gallons X 1000, Liters, Cubic Feet, Cubic Meters
Units of Measure - Energy Measurement
- Rate: kBtu/min, kBtu/hr, kW, MW, hp, tons
- Total: Btu, kBtu, MBtu, kWh, MWh, kJ, MJ
Temperature Measurement
- Fahrenheit, Centigrade
Programming
- Requires PC or laptop running Windows 2000, XP, Vista or Windows 7
- Data Industrial 340BN/MB Programming Kit A-301-20 containing software and Data Industrial Series programming cable is required for programming and setup
- Building Design, HVAC & Plumbing