Series TTE Explosion-Proof RTD Temperature Transmitter
Brand: Dwyer Instruments, LLCThe Series TTE Explosion-Proof RTD Temperature Transmitter is the ideal product for hazardous temperature measurement applications.
The TTE series has seven preprogrammed temperature ranges that are selectable via an internal dip switch.
For those applications that need a custom range, the transmitter can be easily configured for any range between -30 to 250° F with a minimum span of 40° F. The span and zero can be quickly adjusted with a simple push button design.
This unit has optional listings of FM for use in Class I, Division 1, Groups B, C and D, Class II, Division 1, Groups E, F and G and Class III atmospheres or ATEX (Directive 2014/34/EU) for II 2 G Ex db IIC T6...T4 Gb (-20°C = Ta = +70°C), II 1 D Ex ta IIIC T111°C Da (-20°C = Ta = +70°C) and IECEx for Ex db IIC T6...T4 Gb (-20°C = Ta = +70°C), Ex ta IIIC T111°C Da (-20°C = Ta = +70°C).
The compact housing allows for the transmitter to be mounted in virtually any application.
Features- FM Approved for Class I, Groups B, C, D; Class II, Groups E, F, G Classified Explosive Environments
- Optional LCD
- Output Span Selected From Seven Common Ranges or User Determined
1 - 12 of 12 Part Numbers
TTE-104-W
- Probe Length - 4" Probe
- LCD Display - No LCD Display
TTE-106-W
- Probe Length - 6" Probe
- LCD Display - No LCD Display
TTE-109-W
- Probe Length - 9" Probe
- LCD Display - No LCD Display
TTE-112-W
- Probe Length - 12" Probe
- LCD Display - No LCD Display
TTE-115-W
- Probe Length - 15" Probe
- LCD Display - No LCD Display
TTE-118-W
- Probe Length - 18" Probe
- LCD Display - No LCD Display
1 - 12 of 12 Part Numbers
Specifications
Brand
Accessories
- Mounting Bracket for Pipe or Surface Mounting
Accuracy
- ± 0.1 % of Full Scale Transmitter
- ± 0.3 % of Full Scale Probe
Ambient Temperature Range
- -18° to 70° C (0° to 158° F)
Approvals & Certifications
- CE
- FM
Conduit Connection
- 1/2” NPT Female
Display
- 2 Lines x 8-Character LCD
Environmental Protection
- Class 1, Div. 1, Groups B, C, D
- Class II, Div. 1, Groups E, F, G
- Class III, Div. 1, Hazardous Location
- Explosion-proof
- IP66
- NEMA 4X
Insertion 'U' Length
- 2” to 18”
NPT Connection
- 1/2” NPT Female
- 1/2” NPT Male
Output
- 4-20 mA (2-Wire Loop-Powered)
Power Requirement
- 10-35 Vdc
Process Temperature
- -34.4° to 121.1° C (-30° to 250° F)
Proof Pressure
- psi: 2,000 (kPa: 13,800, bar: 138)
Response Time
- 250 milliseconds
Sensor / Probe Diameter
- 2” to 18”
Sensor / Probe Type
- 0.00385 DIN
- Pt1000
Stem Length
- 12” (30.5 cm)
- 15” (38.1 cm)
- 18” (45.7 cm)
- 4” (10.2 cm)
- 6” (15.2 cm)
- 9” (22.9 cm)
Thermal Drift
- ± 0.02 %/°C, Max.
Wetted Materials
- 316 Stainless Steel
- Explosive Process Environments
- Offshore HVAC Monitoring