Yodify Product Library
Instantly add the Level Plus SoClean Magnetostrictive Liquid Level Transmitter and 50,000+ more product series to your store or catalog
Book Your Demo and See How
or create your store
Level Plus SoClean Magnetostrictive Liquid Level Transmitter
Brand: Temposonics an Amphenol CompanyThe Level Plus SoClean liquid level transmitter satisfies the demand for an accurate and robust liquid-level sensor with unsurpassed flexibility to meet most process application conditions.
The SoClean transmitter provides 3-in-1 measurement using one process opening for product level, interface level, and temperature measurements.
Once the transmitter is installed and calibrated there is no requirement for scheduled maintenance or recalibration.
Features- 3-in-1 measurement
- Product
- Interface
- Temperature
- No scheduled maintenance or recalibration
- Inherent accuracy ±1 mm
- Intrinsically safe
- Sanitary finish Ra 25 μin (0.64 μm)
- Electropolished finish Ra 15 μin (0.38 μm)
Specifications
Accuracy
- Inherent Accuracy: ± 0.039” (± 1 mm)
- Temperature Accuracy (Analog, HART): ± 0.28° C (± 0.5° F) Range -40° to 105° C (-40° to 221° F)
- Temperature Accuracy (Modbus, DDA): ± 0.1° C (± 0.2° F) Range -20° to 70° C (-4° to 158° F)
- Temperature Accuracy (Modbus, DDA): ± 0.15° C (± 0.3° F) Range 70° to 100° C (158° to 212° F)
- Temperature Accuracy (Modbus, DDA): ± 0.2° C (± 0.4° F) Range -40° to -20° C (-40° to -4° F)
- Temperature Accuracy (Modbus, DDA): ± 0.5° C (± 0.9° F) Range 100° to 105° C (-40° to 221° F)
Approvals & Certifications
- ISO 9001
- ATEX Ex
- CE
- CEC
- EMC EN 61326-1, EN 61326-2-3, EN 61326-3-2, EN 61000-6-2, EN 61000-6-3, EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-8, EN 61000-4-11
- FM
- IEC
- NEC
BSP Connection
- 3/4” BSPP Male Fitting
Communication
- Output Signal/Protocol: HART
- Output Signal/Protocol: Modbus RTU
Electrical Connectors
- 4-Wire Shielded Cable or Twisted Pair
- NEMA Typical 4X: 1/2” NPT Female Conduit Opening
- Single & Dual Cavity: 3/4” NPT Female Conduit Opening
- Single & Dual Cavity: M20 for ATEX/IECEx Version
Electrical Protection
- Reverse Polarity Protection: Series Diode
Environmental Protection
- Hazardous Area
- Intrinsically Safe
- IP65
- IP66
- NEMA 4X
Humidity
- 0 to 100 % Relative Humidity, Non-Condensing
Length
- Sanitary Pipe: 12 to 300” (305 to 7,620 mm)
Materials of Construction
- Epoxy Coated Aluminum
- Non-Wetted Parts: 316L Stainless Steel
NPT Connection
- 3/4” NPT MaleFitting
Operating Temperature
- Electronics: -40° to 71° C (-40° to 160° F)
- Sensing Element: -40° to 125° C (-40° to 257° F)
- Temperature Element: -40° to 105° C (-40° to 221° F)
Pressure Range
- bar: 0 to 137.9
- kPa: 0 to 13,790
- psi: 0 to 2,000
- Vessel Pressure Rigid Pipe psi: 2,000 (kPa: 13,790, bar: 137.9)
Principle of Operation
- Magnetostrictive Principle
Repeatability
- 0.001 % of Full Scale
- 0.015” (0.381 mm)
Voltage
- Input Voltage: 10.5-28 Vdc
Wetted Materials
- 316L Stainless Steel
- Process Control
- Batching
- Bioreactor
- Food and Beverage
- Pharmaceutical
- Cosmetics