Level Plus SoClean Magnetostrictive Liquid Level Transmitter

Brand: Temposonics an Amphenol Company

The Level Plus SoClean liquid level transmitter satisfies the demand for an accurate and robust liquid-level sensor with unsurpassed flexibility to meet most process application conditions. 

The SoClean transmitter provides 3-in-1 measurement using one process opening for product level, interface level, and temperature measurements. 

Once the transmitter is installed and calibrated there is no requirement for scheduled maintenance or recalibration.
Features
  • 3-in-1 measurement
    • Product
    • Interface
    • Temperature
  • No scheduled maintenance or recalibration
  • Inherent accuracy ±1 mm
  • Intrinsically safe
  • Sanitary finish Ra 25 μin (0.64 μm)
  • Electropolished finish Ra 15 μin (0.38 μm)

Specifications

Accuracy

  • Inherent Accuracy: ± 0.039" (± 1 mm)
  • Temperature Accuracy (Analog, HART): ± 0.28° C (± 0.5° F) Range -40° to 105° C (-40° to 221° F)
  • Temperature Accuracy (Modbus, DDA): ± 0.1° C (± 0.2° F) Range -20° to 70° C (-4° to 158° F)
  • Temperature Accuracy (Modbus, DDA): ± 0.15° C (± 0.3° F) Range 70° to 100° C (158° to 212° F)
  • Temperature Accuracy (Modbus, DDA): ± 0.2° C (± 0.4° F) Range -40° to -20° C (-40° to -4° F)
  • Temperature Accuracy (Modbus, DDA): ± 0.5° C (± 0.9° F) Range 100° to 105° C (-40° to 221° F)

Approvals & Certifications

  • ISO 9001
  • ATEX Ex
  • CE
  • CEC
  • EMC EN 61326-1, EN 61326-2-3, EN 61326-3-2, EN 61000-6-2, EN 61000-6-3, EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-8, EN 61000-4-11
  • FM
  • IEC
  • NEC

BSP Connection

  • 3/4" BSPP Male Fitting

Communication

  • Output Signal/Protocol: HART
  • Output Signal/Protocol: Modbus RTU

Electrical Connectors

  • 4-Wire Shielded Cable or Twisted Pair
  • NEMA Typical 4X: 1/2" NPT Female Conduit Opening
  • Single & Dual Cavity: 3/4" NPT Female Conduit Opening
  • Single & Dual Cavity: M20 for ATEX/IECEx Version

Electrical Protection

  • Reverse Polarity Protection: Series Diode

Environmental Protection

  • Hazardous Area
  • Intrinsically Safe
  • IP65
  • IP66
  • NEMA 4X

Humidity

  • 0 to 100 % RH, Non-Condensing

Length

  • Sanitary Pipe: 12 to 300" (305 to 7,620 mm)

Materials of Construction

  • Epoxy Coated Aluminum
  • Non-Wetted Parts: 316L Stainless Steel

NPT Connection

  • 3/4" NPT MaleFitting

Operating Temperature

  • Electronics: -40° to 71° C (-40° to 160° F)
  • Sensing Element: -40° to 125° C (-40° to 257° F)
  • Temperature Element: -40° to 105° C (-40° to 221° F)

Pressure Range

  • bar: 0 to 137.9
  • kPa: 0 to 13,790
  • psi: 0 to 2,000
  • Vessel Pressure Rigid Pipe psi: 2,000 (kPa: 13,790, bar: 137.9)

Principle of Operation

  • Magnetostrictive Principle

Repeatability

  • 0.001 % of Full Scale
  • 0.015" (0.381 mm)

Voltage

  • Input Voltage: 10.5-28 Vdc

Wetted Materials

  • 316L Stainless Steel

  • Process Control
  • Batching
  • Bioreactor
  • Food and Beverage
  • Pharmaceutical
  • Cosmetics