Yodify Product Library
Instantly add the TB82PH 2-Wire Single Input Transmitter and 50,000+ more product series to your store or catalog
Book Your Demo and See How
or create your store
TB82PH 2-Wire Single Input Transmitter
Brand: ABB GroupThe rugged ABB TB82 2-wire transmitter is designed for a broad range of industries from chemical, power and pulp & paper to water & wastewater treatment.
The TB82 is available with traditional programmable outputs or with advanced digital communications using Foundation Fieldbus (FF), PROFIBUS PA (PA) or HART.
Features- Intuitive user interface
- easy-to-use menus guide the operator through set-up, calibration and maintenance
- Advanced digital communications
- available with PROFIBUS® PA, FOUNDATION™ Fieldbus or HART communications
- Hazardous area transmitters
- withstand the harshest environments
- NEMA 4X / IP65 housings
- Large, easy-to-read display
- shows primary measurement together with user-selectable secondary display (temperature, output current or sensor input)
- Programmable security codes
- prevents unauthorized modifications to transmitter configuration and calibration
- Intrinsically safe, non-incendive design
- enables use in hazardous areas
1 - 12 of 480 Part Numbers
TB82PH1010000
- Input Type - pH, ORP, Plon
- Programming Option - Basic
- Digital Communications Option - None (Analog Only)
- Lightning Suppressor - Included
- Housing Type - Powder-Coated Aluminum
- Mounting Options - None
- Agency Approvals - None
- Tag - None
TB82PH1010001
- Input Type - pH, ORP, Plon
- Programming Option - Basic
- Digital Communications Option - None (Analog Only)
- Lightning Suppressor - Included
- Housing Type - Powder-Coated Aluminum
- Mounting Options - None
- Agency Approvals - None
- Tag - Stainless Steel
TB82PH1010002
- Input Type - pH, ORP, Plon
- Programming Option - Basic
- Digital Communications Option - None (Analog Only)
- Lightning Suppressor - Included
- Housing Type - Powder-Coated Aluminum
- Mounting Options - None
- Agency Approvals - None
- Tag - Mylar
TB82PH1010010
- Input Type - pH, ORP, Plon
- Programming Option - Basic
- Digital Communications Option - None (Analog Only)
- Lightning Suppressor - Included
- Housing Type - Powder-Coated Aluminum
- Mounting Options - None
- Agency Approvals - FM (Factory Mutual)
- Tag - None
TB82PH1010011
- Input Type - pH, ORP, Plon
- Programming Option - Basic
- Digital Communications Option - None (Analog Only)
- Lightning Suppressor - Included
- Housing Type - Powder-Coated Aluminum
- Mounting Options - None
- Agency Approvals - FM (Factory Mutual)
- Tag - Stainless Steel
TB82PH1010012
- Input Type - pH, ORP, Plon
- Programming Option - Basic
- Digital Communications Option - None (Analog Only)
- Lightning Suppressor - Included
- Housing Type - Powder-Coated Aluminum
- Mounting Options - None
- Agency Approvals - FM (Factory Mutual)
- Tag - Mylar
TB82PH1010020
- Input Type - pH, ORP, Plon
- Programming Option - Basic
- Digital Communications Option - None (Analog Only)
- Lightning Suppressor - Included
- Housing Type - Powder-Coated Aluminum
- Mounting Options - None
- Agency Approvals - CSA (Canadian Standards Association)
- Tag - None
TB82PH1010021
- Input Type - pH, ORP, Plon
- Programming Option - Basic
- Digital Communications Option - None (Analog Only)
- Lightning Suppressor - Included
- Housing Type - Powder-Coated Aluminum
- Mounting Options - None
- Agency Approvals - CSA (Canadian Standards Association)
- Tag - Stainless Steel
TB82PH1010022
- Input Type - pH, ORP, Plon
- Programming Option - Basic
- Digital Communications Option - None (Analog Only)
- Lightning Suppressor - Included
- Housing Type - Powder-Coated Aluminum
- Mounting Options - None
- Agency Approvals - CSA (Canadian Standards Association)
- Tag - Mylar
TB82PH1010030
- Input Type - pH, ORP, Plon
- Programming Option - Basic
- Digital Communications Option - None (Analog Only)
- Lightning Suppressor - Included
- Housing Type - Powder-Coated Aluminum
- Mounting Options - None
- Agency Approvals - ATEX
- Tag - None
TB82PH1010031
- Input Type - pH, ORP, Plon
- Programming Option - Basic
- Digital Communications Option - None (Analog Only)
- Lightning Suppressor - Included
- Housing Type - Powder-Coated Aluminum
- Mounting Options - None
- Agency Approvals - ATEX
- Tag - Stainless Steel
TB82PH1010032
- Input Type - pH, ORP, Plon
- Programming Option - Basic
- Digital Communications Option - None (Analog Only)
- Lightning Suppressor - Included
- Housing Type - Powder-Coated Aluminum
- Mounting Options - None
- Agency Approvals - ATEX
- Tag - Mylar
1 - 12 of 480 Part Numbers
Specifications
Brand
Environmental Protection
- IP65
- NEMA 4X
Range
- pH: 0 to 14 pH (with -2 to +16 pH over Range)
- ORP/pIon: ± 1999 mV
Temperature Sensor
- Pt100,
- 3 k Ω Balco
Temperature Range
- Display: -20° to 300° C (-4° to 572° F)
Accuracy
- pH display: ± 0.01 pH
- ORP/plon display: ± 1 mV
- Temperature display: 1° C or 1° F
- Output: ± 0.02 mA (non-FF devices)
Power Requirement
- Standard 14-53 Vdc
Certifications & Approvals
- EMC
- FM
- CSA
- IECEx
- ATEX
Stability
- Output: ± 0.01 mA
- ORP/pIon: ± 1 mV
- pH: ± 0.01 pH
- Temperature: 1° C or 1° F
Output Span
- Maximum -1999 to 1999 mV
- Maximum 14 pH units
- Minimum 100 mV
- Minimum 1.00 pH
Operating Temperature
- -20° to 60° C (-4° to 140° F)
Storage Temperature
- -40° to 70° C (-40° to 158° F)
Humidity
- Up to 95 % Relative Humidity
Housing Material
- Anodized Aluminum Alloy with Polyester Powder Coating
Mounting
- Pipe-mount
- Panel-mount
- Wall Mount
Documentation
Brochure
Catalog
Manual
- Product selection guide - pH sensor cable selection pdf 66 KB
- Quick programming guide - Type TB82 Series Advantage Analyzers pdf 27 KB
- TB82 Conductivity Transmitters with ATEX Certification pdf 2.7 MB
- TB82 HART Supplement (Board rev. F and higher) pdf 475 KB
- TB82PH Transmitter with FOUNDATION fieldbus pdf 1.5 MB
- TB82PH Transmitter with PROFIBUS PA pdf 1.6 MB