Specifications
Brand
Accuracy
- P2594 (100 mm) & P2596 (160 mm): ± 1.0 % of Full Scale
- P2592 (63 mm): ± 1.6 % of Full Scale
Blowout Protection
- Top, Rubber Disc for 63 mm
- Back, Rubber Disc for 100 & 160 mm
Case
- 304 Stainless Steel
Cover
- 304 Stainless Steel Bayonet Typical
Degree of Protection
- EN 60529 / IEC 529 / IP67
Dial
- White Aluminum with Black Graduations
Element
- ≥ 6 MPa: Helical Typical Bourdon Tube
- < 6 MPa: C-Typical Bourdon Tube
- Brass
- < 10 MPa: C-Typical Bourdon Tube
- Model: P2592 (63 mm)
- Model: P2594 (100 mm) & P2596 (160 mm)
- ≥ 10 MPa: Helical Typical Bourdon Tube with 316 Stainless Steel
Filling Liquid
- Glycerine
Movement
- 63 mm: Brass
- 100 & 160 mm: Stainless Steel
Nominal Diameter
- 63, 100 & 160 mm
Options
- Zero Adjustable Pointer
- (Only Available with Diameter 100 & 160 mm)
- Silicone Filling
Pointer
- Black Painted Aluminum Alloy
Pressure Connection
- Brass
Process Connection
- 100 & 160 mm: 3/8”, 1/2” PT, NPT & PF
- 63 mm: 1/4” PT, NPT & PF
Scale Range (MPa, KPa, bar)
- 100 & 160 mm: -0.1 ~ 0 to 0 ~ 100 MPa
- 63 mm: -0.1 ~ 0 to 0 ~ 40 MPa
Temperature Effect
- Accuracy at Temperature Above & Below the Reference Temperature (20° C) Will be Effected by Approximately
- ± 0.4 % Per 10° C of Full Scale
Window Material
- Laminated Safety Glass
Working Pressure
- 100 % of Full Scale (100 & 160 mm)
- Over Range Protection: 130 % of Full Scale
- Steady: 75 % of Full Scale (63 mm)
Working Temperature
- Fluid: Max.
- -40° ~ 60° C (with Silicone Filling)
- Ambient: -20° to 60° C (with Glycerin Filling)