Yodify Product Library
Instantly add the TTC200 Temperature Transmitter and 50,000+ more product series to your store or catalog
Book Your Demo and See How
or create your store
TTC200 Temperature Transmitter
Brand: Status InstrumentsThe TTC200 is our mid range transmitter for thermocouple and mVsensors. It can accept 13 different types of thermocouple sensors as well as mV up to 200 mV.
This product has a calibration feature where the output can be matched to the sensor on the input. It can be matched at zero, or both zero and span ends of the temperature range being measured.
This is typically used when the product is being supplied with a calibration certificate matched to a particular temperature probe.
Specifications
Brand
Accuracy
- (mA Output/2,000) or 5 µA whichever is greater, Drift 1 µA/°C
- ± 0.02 % of Full Scale (-100 to 200 mV)
- ± 0.1 % of Full Scale ± 0.5° C (± 0.9° F) (Plus Sensor Error)
- ± 0.2 % of Full Scale ± 0.5° C (± 0.9° F) (Plus Sensor Error)
Ambient Temperature Range
- Configuration Ambient: 10° to 30° C (50° to 86° F)
Approvals & Certifications
- ATEX - CE II 1 GD, Ex ia IIC T4 Ga, Ex iaD 20 T1 35° C Da, Tamp = 40° to 85° C
- CE - BS EN 61326
Burn-Out
- Downscale - 3.8 mA
- Up Scale - 21.5 mA
Communication
- Baud Rate: 1,200 bit/sec
- USB 2.0
Connection Style
- Screw Terminals
Current
- Excitation Current: < 200 UA
Environmental Protection
- IP65
Humidity
- 10 to 90 % Relative Humidity, Non-Condensing
Input
- -100 to 200 mV
Isolation
- Input to Output: 500 Vdc
Linearization
- (2 to 22) Segments mV to Process
Mounting
- Head Mount
Operating Temperature
- Operating Ambient Temperature: -40° to 85° C (-40° to 185° F)
Output
- 2-Wire
- 4-20 mA Current Loop
Output Load
- (Vsupply-10)/20 kiloohms
Power Supply
- < 1 W Full Power
- 10-30 Vdc
Response Time
- 500 milliseconds
- Start Up: 5 seconds
Sensor, Probe Connection
- Screw Terminal 2.5 mm, Max.
Sensor, Probe Diameter
- 1.69” (43 mm)
Sensor, Probe Type
- B Thermocouple
- C Thermocouple
- D Thermocouple
- E Thermocouple
- J Thermocouple
- K Thermocouple
- L Thermocouple
- N Thermocouple
- R Thermocouple
- T Thermocouple
- U Thermocouple
- W Thermocouple
Storage Temperature
- Ambient Storage Temperature: -50° to 85° C (-58° to 185° F)
System Requirements
- Windows® XP
Temperature Range
- Cold Junction: -40° to 85° C (-40° to 185° F)
- Thermocouple: -200° to 2,300° C (-328° to 4,172° F)
Thermal Drift
- 1 µA/°C
- Thermocouple Offset: 0.1° C/°C
Update Time
- 160 milliseconds
- Warm-Up: 2 minutes