Yodify Product Library
Instantly add the NUS-4 Ultrasonic Level & Flow Meter and 50,000+ more product series to your store or catalog  
Book Your Demo and See How
or create your store

NUS-4 Ultrasonic Level & Flow Meter

Brand: KOBOLD Instruments, Inc

The Kobold ultrasonic level meter, model NUS-4, is used for non-contact, continuous level and volume measurement in vessels or for flow measurement in open channels. 

Level measurement technology based on the non-contacting ultrasonic principle is especially suited for applications where, for any reason, no physical contact can be established to the surface of the material to be measured.

Such reasons may include corrosive attack by the process medium against the measuring device material (acids), possible contamination (sewage) or particles of the process medium adhering to the measuring device (adhesive materials).

The ultrasonic level metering technology is based on the principle of measuring the time required for the  ultrasound pulses to make a round trip from the sensor to the level to be measured and back.

The sensor emits an ultrasonic pulse train and receives the echoes reflected. The electronic evaluates the echo time of the pulses and determines the level. The evaluating electronics is mounted compact on the unit. 

For remote transmission, a norm signal output and for monitoring purposes, a relay contact is available. For programming and for local display, the units may be delivered with an optional pluggable programming unit with LCD display.

The sensors have a  total beam angle of 5°-7° at -3 dB. This ensures a reliable measurement in narrow silos with uneven side walls as well as in process tanks with various protruding objects. 

Furthermore, as a result of the narrow beam angle - the emitted ultrasonic signals have an outstanding focusing - deep penetration through gases, vapour and foam is ensured.

Specifications

Accuracy

  • ± 0.2 % of Reading
  • 0.05 % of Full Scale

Ambient Temperature Range

  • -30° to 70° C (-22° to 158° F)

BSP Connection

  • G 1-1/2” Female
  • G 2” Female

Communication

  • HART

Configuration

  • 4-20 mA (3.9 to 20.5 mA) Galvanically Isolated - Analog Output

Delay Time

  • 10, 30, 60 seconds Programmable

Display

  • 6-Digit Display
  • Bar Graph
  • LCD Display

Electrical Connectors

  • 2 x 1/2” NPT, Wire Cross Section 0.5 to 1.5 mm²
  • 2 x M20 x 1.5 Cable Gand

Enclosure / Body Material

  • Powder-Coated Aluminum

Environmental Protection

  • IP67
  • IP68

Flange Size - 3” (DN 80)

  • 3” (DN 80) - PN 16

Flange Size - 5” (DN 125)

  • 5” (DN 125) - PN 16

Flange Size - 6” (DN 150)

  • 6” (DN 150) - PN 16

Frequency

  • 20 to 80 kHz

Load

  • Maximum

Materials of Construction

  • Glass Fibre Reinforced - Display
  • PBT - Display

Mounting Position

  • Vertical to the Product Surface

NPT Connection

  • 1-1/2” NPT Female
  • 2” NPT Female

Operating Pressure

  • psi: 7.2 to 43.5 (kPa: 50 to 300, bar: 0.5 to 3)

Output

  • 30 Vdc, 1 A - Switching Output
  • 4-20 mA

Output Format

  • Relay Output

Power

  • Maximum

Process Temperature

  • -30° to 90° C (-22° to 194° F)

Resolution

  • 0.04” (1 mm) - Measuring Distance 32.8 feet (10 m)

Reverse Polarity Protection

  • Yes

Sensor / Probe Material

  • Polypropylene (PP)
  • PVDF

Sensor / Probe Style

  • Ultrasonic

Size

  • 0.23” to 0.47” (6 to 12 mm) - Cable Diameter

Supply Voltage

  • 12-36 Vdc, 2-Wire

Switch Type

  • SPDT