KRPC Differential Pressure Transmitter

Brand: Kele

The Kele KRPC Series room pressure monitor is used to measure differential pressure in the range of ±0.125" to 1" WC or ±30 to 250 Pa. 

It combines precision high sensitivity silicon sensing capabilities and the latest ASIC technology to substantially reduce offset errors due to changes in temperature, stability to warmup, long term instability and position sensitivity. It is ideal for monitoring pressure for air or other clean inert gas. 

It features field selectable bi-directional pressure ranges and output signal types for the most flexible application. The device has an on-board auto-zero function, backlit LCD and alarm function with silence switch.
Features
    Low Pressure Monitoring to ±0.125" WC (30 Pa) Four Selectable Ranges per Model Selectable Analog Output Model BACnet Communications Model Alarm Functions with Selectable Trip Point Easy Set up via Menu on LCD Display

1 - 12 of 12 Part Numbers
KRPC1
KRPC1
  • Pressure Range - ± 1" WC, ± 0.5" WC, ± 125 Pa, ± 250 Pa Ranges
  • BACnet Communication - Without BACnet Communication
  • Port - No Port
KRPC1-AC
KRPC1-AC
  • Pressure Range - ± 1" WC, ± 0.5" WC, ± 125 Pa, ± 250 Pa Ranges
  • BACnet Communication - Without BACnet Communication
  • Port - Continental Pick-Up Port
KRPC1-BAC
KRPC1-BAC
  • Pressure Range - ± 1" WC, ± 0.5" WC, ± 125 Pa, ± 250 Pa Ranges
  • BACnet Communication - With BACnet Communication
  • Port - No Port
KRPC1-BAC-AC
KRPC1-BAC-AC
  • Pressure Range - ± 1" WC, ± 0.5" WC, ± 125 Pa, ± 250 Pa Ranges
  • BACnet Communication - With BACnet Communication
  • Port - Continental Pick-Up Port
KRPC1-BAC-SP
KRPC1-BAC-SP
  • Pressure Range - ± 1" WC, ± 0.5" WC, ± 125 Pa, ± 250 Pa Ranges
  • BACnet Communication - With BACnet Communication
  • Port - Stainless Plate Pick-Up Port
KRPC1-SP
KRPC1-SP
  • Pressure Range - ± 1" WC, ± 0.5" WC, ± 125 Pa, ± 250 Pa Ranges
  • BACnet Communication - Without BACnet Communication
  • Port - Stainless Plate Pick-Up Port
KRPC2
KRPC2
  • Pressure Range - ± 0.25" WC, ± 0.125" WC Pa, ± 30 Pa, ± 60 Pa Ranges
  • BACnet Communication - Without BACnet Communication
  • Port - No Port
KRPC2-AC
KRPC2-AC
  • Pressure Range - ± 0.25" WC, ± 0.125" WC Pa, ± 30 Pa, ± 60 Pa Ranges
  • BACnet Communication - Without BACnet Communication
  • Port - Continental Pick-Up Port
KRPC2-BAC
KRPC2-BAC
  • Pressure Range - ± 0.25" WC, ± 0.125" WC Pa, ± 30 Pa, ± 60 Pa Ranges
  • BACnet Communication - With BACnet Communication
  • Port - No Port
KRPC2-BAC-AC
KRPC2-BAC-AC
  • Pressure Range - ± 0.25" WC, ± 0.125" WC Pa, ± 30 Pa, ± 60 Pa Ranges
  • BACnet Communication - With BACnet Communication
  • Port - Continental Pick-Up Port
KRPC2-BAC-SP
KRPC2-BAC-SP
  • Pressure Range - ± 0.25" WC, ± 0.125" WC Pa, ± 30 Pa, ± 60 Pa Ranges
  • BACnet Communication - With BACnet Communication
  • Port - Stainless Plate Pick-Up Port
KRPC2-SP
KRPC2-SP
  • Pressure Range - ± 0.25" WC, ± 0.125" WC Pa, ± 30 Pa, ± 60 Pa Ranges
  • BACnet Communication - Without BACnet Communication
  • Port - Stainless Plate Pick-Up Port
1 - 12 of 12 Part Numbers

Specifications

Brand

Accuracy

  • ± 1 % of Full Scale Output
  • ± 2 % of Full Scale Output - for inches WC: 0.125 & Pa: 30 Ranges

Alarm

  • Audible 85 dB - On-Board Buzzer
  • Red Flashing LED - Alarm Visual

Communication

  • 2-Wire RS-485
  • BACnet MSTP
  • Baud Rate: 9600, 19200, 38400, 76800

Current

  • 20 mA or 48 Vdc - Remote Buzzer Current
  • 5 mA or 9 Vdc - Remote Buzzer Current

Display

  • 1.5” x 0.65” (38.1 x 16.5 mm) - LCD Display Size
  • LCD Display

Electrical Connectors

  • 14 to 22 AWG - Wiring Connections
  • Screw Typical Terminal Block - Wiring Connection

Electrical Contacts

  • Normally Open

Enclosure, Body Material

  • White ABS

Environmental Protection

  • IP30
  • NEMA 1

Humidity

  • Operating Humidity: 10 to 90 % Non-Condensing Relative Humidity

Media

  • Dry Air
  • Inert Gas

Mounting

  • Wall Mounted

Operating Temperature

  • 0° to 60° C (32° to 140° F)

Output

  • 0-10 Vdc, 3-Wire
  • 0-5 Vdc, 3-Wire
  • 24 Vdc - Remote Buzzer Output
  • 4-20 mA, 3-Wire

Output Impedence

  • 2 kiloohms Min. (Voltage)
  • 750 ohms, Max.

Power Supply

  • 24 Vac/dc, ± 10 %

Pressure Range

  • Inches WC: ± 0.125 to ± 1
  • mbar: 0.31 to 2.5
  • mmHg: 0.23 to 1.86
  • Pa: ± 30 to ± 250

Relay Output

  • 2 A at 120 Vac - Alarm Relay Output
  • 2 A at 30 Vdc - Alarm Relay Output

Response Time

  • 0 to 60 seconds

Span & Zero Adjustments

  • Push Button Auto-Zero - Zero Adjustment

Stability

  • ± 1 % of Full Scale - Max.

Temperature Effect

  • < ± 3.5 % of Full Scale - Max.

Temperature Range

  • 5° to 50° C (41° to 122° F)

Tube Connection

  • 1/4” O.D. Tube