Yodify Product Library
Instantly add the Fluxus SIL G Functional Safety Gas Flow Meter and 50,000+ more product series to your store or catalog
Book Your Demo and See How
or create your store
Fluxus SIL G Functional Safety Gas Flow Meter
Brand: FLEXIMFunctional Safety approved Gas Flowmeter.
The FLUXUS non-invasive ultrasonic gas flow meters have always been the first choice when it comes to maintaining accurate measurements in harsh conditions – e.g. during the flow measurement of highly pressurized, aggressive, toxic or highly explosive gaseous media.
FLUXUS measures from the safe side: From outside.
The clamp-on ultrasonic transducers are simply mounted on the outside of the pipe. Without any risk of leak and during ongoing operation.
The ultrasonic measuring method doesn’t need any wetted devices, works independent of the pressure inside the pipe and is not subjected to mechanical stress which means it is practically wear-free.
As the wetted parts of inline measuring devices are not subject to the Failure Mode Effects and Diagnostics Analysis (FMEDA), they are not included in the scope of certification - presenting a safety risk.
On the other hand, the SIL 2 certification of the FLUXUS non-invasive flow meter includes the entire measuring system -the measuring transmitters and transducers.
Safety without interruption.
The advantages of FLEXIMs non-invasive flow measurement technology pay off all the more over the entire lifecycle:
There is never any need to interfere with the pipeline system when carrying out periodic inspections.
The self-diagnosis functions of the FLUXUS mean retests can be carried out easily to accurately assess the reliability and quality of the measurement.
Even more detailed functional tests such as alarm tests or tests for monitoring compliance with measuring accuracy requirements never interfere with plant availability.
Specifications
Brand
Communication Protocol
- Modbus RTU
Data Logger Capacity
- > 100,000 Values: All Quantities, Summed Measurings & Diagnostics
Degree of Protection Transducers
- Up to NEMA 4X (IP68)
Flow Velocity Range
- 0.03 ft/sec to > 100 ft/sec (Dependent on Pipe Size)
Fluxus G70X
- FM Class I, Div. 2, ATEX, IECEx Zone 2 Approval (Optional), IP66, Aluminum or Stainless Steel Housing Variants
Fluxus G80X
- FM Class I, Div. 1, ATEX, IECEx Zone 1 Approval, IP66, Aluminum or Stainless Steel Housing Variants - Suitable for Offshore
Measurement Accuracy
- 1 % to 3 % of Reading ± 0.3 ft/sec, Depending on Application, 0.5 % of Reading ± 0.03 ft/sec, Field Calibrated
Measurement Accuracy (Field Calibrated)
- ± 0.5 % of Reading ± 0.03 ft/sec
Measuring Quantities
- Volume Flow Rate, Mass Flow Rate, Flow Velocity
Operating Temperature of the Transducers at Pipe Wall
- -40° to +210° F
Operating Temperature of the Transmitter
- 14° to 140° F
Pipe Diameter Range
- 0.4 to 83”
Power Supply
- 100 to 240 Vac / 50/60 Hz or 20 to 32 Vdc
Repeatability
- 0.15 % of Reading ± 0.03 ft/sec
Documentation
Brochure
Specifications
- FLUXUS SIL G7 Technical Specification DE pdf 64 KB
- FLUXUS SIL G7 Technical Specification EN pdf 63 KB
- FLUXUS SIL G7 Technical Specification FR pdf 64 KB
- FLUXUS SIL G7 Technical Specification US pdf 78 KB
- FLUXUS SIL G8 Technical Specification DE pdf 74 KB
- FLUXUS SIL G8 Technical Specification EN pdf 73 KB
- FLUXUS SIL G8 Technical Specification ES pdf 74 KB
- FLUXUS SIL G8 Technical Specification FR pdf 74 KB
- FLUXUS SIL G8 Technical Specification NL pdf 73 KB
- FLUXUS SIL G8 Technical Specification RU pdf 319 KB