Brand: R. STAHL AGR. STAHL Series 8403 ammeters are installed in Ex e type of protection enclosures. They provide measured values for circuits which can be quickly compared with the desired values via a red pointer affixed on the outside. The devices work with a moving iron movement with accuracy class 2.5.
Features- Ammeters in various versions, for Ex e enclosures
- Quicker comparison of measured values using externally adjustable red pointers on the device
- On models with CT connection (1 A, 5 A), easy and quick measuring range assignment via retractable scale plate
1 - 11 of 11 Part Numbers
262688
Ammeters in various versions, for Ex e enclosures
Quicker comparison of measured values using externally adjustable red pointers on the device
On models with CT connection (1 A, 5 A), easy and quick measuring range assignment via retractable scale plate
Ambient Conditions
- Ambient temperature - -40 °C ... +70 °C
- Ambient temperature max. - +70 °C
- Ambient temperature min. - -40 °C
Components
- Scale - 0 - 1 / 2 A
Electrical Data
- Frequency - 0/100 Hz
- Measuring range max. - 1 A
- Measuring range min. - 0 A
- Overload capacity - 50 x IN 1 sec
- Power dissipation - 0.670 VA
- Rated operational current AC - 1.000 - 1.000 A
Explosion Protection
- Application range (zones) - 1, 2
- ATEX gas certificate - SIQ 17 ATEX 192 U
- Gas explosion protection ATEX - II 2 G Ex eb IIC Gb
- Gas explosion protection IECEx - Ex eb IIC Gb
- IECEX gas certificate - IECEx SIQ 17.0003U
General
- Functional Description - R. STAHL Series 8403 ammeters are installed in Ex e type of protection enclosures. They provide measured values for circuits which can be quickly compared with the desired values via a red pointer affixed on the outside. The devices work with a moving iron movement with accuracy class 2.5.
- Highlights - Ammeters in various versions, for Ex e enclosures Quicker comparison of measured values using externally adjustable red pointers on the device On models with CT connection (1 A, 5 A), easy and quick measuring range assignment via retractable scale plate
- Product Description - Moving iron ammeter direct measuring
- Product Type - 8403/6-1-2
- Title Product Variant Technical Data - 8403/6-1-2 Ammeter direct display
- WebCode - 8403B
Mechanical Data
- Accuracy class - 2.5
- Connection cross-section finely stranded max. - 6.00 mm²
- Connection cross-section solid max. - 10.00 mm²
- Connection cross-section solid min. - 2.50 mm²
- Degree of protection (IP) - IP54
- Depth - 72.000 mm
- Enclosure material - Polycarbonate
- Height - 71.200 mm
- Overload scale - 2x
- Silicone-free - No
- Terminal degree of protection (IP) - IP20
- Weight - 0.300 kg
- Width - 72.000 mm
262689
Ammeters in various versions, for Ex e enclosures
Quicker comparison of measured values using externally adjustable red pointers on the device
On models with CT connection (1 A, 5 A), easy and quick measuring range assignment via retractable scale plate
Ambient Conditions
- Ambient temperature - -40 °C ... +70 °C
- Ambient temperature max. - +70 °C
- Ambient temperature min. - -40 °C
Components
- Scale - without
Electrical Data
- Frequency - 0/100 Hz
- Measuring range max. - 1 A
- Measuring range min. - 0 A
- Overload capacity - 50 x IN 1 sec
- Power dissipation - 0.670 VA
- Rated operational current AC - 1.000 - 1.000 A
Explosion Protection
- Application range (zones) - 1, 2
- ATEX gas certificate - SIQ 17 ATEX 192 U
- Gas explosion protection ATEX - II 2 G Ex eb IIC Gb
- Gas explosion protection IECEx - Ex eb IIC Gb
- IECEX gas certificate - IECEx SIQ 17.0003U
General
- Functional Description - R. STAHL Series 8403 ammeters are installed in Ex e type of protection enclosures. They provide measured values for circuits which can be quickly compared with the desired values via a red pointer affixed on the outside. The devices work with a moving iron movement with accuracy class 2.5.
- Highlights - Ammeters in various versions, for Ex e enclosures Quicker comparison of measured values using externally adjustable red pointers on the device On models with CT connection (1 A, 5 A), easy and quick measuring range assignment via retractable scale plate
- Product Description - Moving iron ammeter For transducer
- Product Type - 8403/6-1T-2
- Title Product Variant Technical Data - 8403/6-1T-2 Converter Ammeter Ue=2
- WebCode - 8403B
Mechanical Data
- Accuracy class - 2.5
- Connection cross-section finely stranded max. - 6.00 mm²
- Connection cross-section solid max. - 10.00 mm²
- Connection cross-section solid min. - 2.50 mm²
- Degree of protection (IP) - IP54
- Depth - 72.000 mm
- Enclosure material - Polycarbonate
- Height - 71.200 mm
- Overload scale - 2x
- Silicone-free - No
- Terminal degree of protection (IP) - IP20
- Weight - 0.300 kg
- Width - 72.000 mm
262690
Ammeters in various versions, for Ex e enclosures
Quicker comparison of measured values using externally adjustable red pointers on the device
On models with CT connection (1 A, 5 A), easy and quick measuring range assignment via retractable scale plate
Ambient Conditions
- Ambient temperature - -40 °C ... +70 °C
- Ambient temperature max. - +70 °C
- Ambient temperature min. - -40 °C
Components
- Scale - without
Electrical Data
- Frequency - 0/100 Hz
- Measuring range max. - 1 A
- Measuring range min. - 0 A
- Overload capacity - 50 x IN 1 sec
- Power dissipation - 0.670 VA
- Rated operational current AC - 1.000 - 1.000 A
Explosion Protection
- Application range (zones) - 1, 2
- ATEX gas certificate - SIQ 17 ATEX 192 U
- Gas explosion protection ATEX - II 2 G Ex eb IIC Gb
- Gas explosion protection IECEx - Ex eb IIC Gb
- IECEX gas certificate - IECEx SIQ 17.0003U
General
- Functional Description - R. STAHL Series 8403 ammeters are installed in Ex e type of protection enclosures. They provide measured values for circuits which can be quickly compared with the desired values via a red pointer affixed on the outside. The devices work with a moving iron movement with accuracy class 2.5.
- Highlights - Ammeters in various versions, for Ex e enclosures Quicker comparison of measured values using externally adjustable red pointers on the device On models with CT connection (1 A, 5 A), easy and quick measuring range assignment via retractable scale plate
- Product Description - Moving iron ammeter For transducer
- Product Type - 8403/6-1T-5
- Title Product Variant Technical Data - 8403/6-1T-5 Converter Ammeter Ue=5
- WebCode - 8403B
Mechanical Data
- Accuracy class - 2.5
- Connection cross-section finely stranded max. - 6.00 mm²
- Connection cross-section solid max. - 10.00 mm²
- Connection cross-section solid min. - 2.50 mm²
- Degree of protection (IP) - IP54
- Depth - 72.000 mm
- Enclosure material - Polycarbonate
- Height - 71.200 mm
- Overload scale - 5x
- Silicone-free - No
- Terminal degree of protection (IP) - IP20
- Weight - 0.300 kg
- Width - 72.000 mm
262711
Ammeters in various versions, for Ex e enclosures
Quicker comparison of measured values using externally adjustable red pointers on the device
On models with CT connection (1 A, 5 A), easy and quick measuring range assignment via retractable scale plate
Ambient Conditions
- Ambient temperature - -40 °C ... +70 °C
- Ambient temperature max. - +70 °C
- Ambient temperature min. - -40 °C
Components
- Scale - 0 - 2.5 / 5 A
Electrical Data
- Frequency - 0/100 Hz
- Measuring range max. - 2,5 A
- Measuring range min. - 0 A
- Overload capacity - 50 x IN 1 sec
- Power dissipation - 0.670 VA
- Rated operational current AC - 2.500 - 2.500 A
Explosion Protection
- Application range (zones) - 1, 2
- ATEX gas certificate - SIQ 17 ATEX 192 U
- Gas explosion protection ATEX - II 2 G Ex eb IIC Gb
- Gas explosion protection IECEx - Ex eb IIC Gb
- IECEX gas certificate - IECEx SIQ 17.0003U
General
- Functional Description - R. STAHL Series 8403 ammeters are installed in Ex e type of protection enclosures. They provide measured values for circuits which can be quickly compared with the desired values via a red pointer affixed on the outside. The devices work with a moving iron movement with accuracy class 2.5.
- Highlights - Ammeters in various versions, for Ex e enclosures Quicker comparison of measured values using externally adjustable red pointers on the device On models with CT connection (1 A, 5 A), easy and quick measuring range assignment via retractable scale plate
- Product Description - Moving iron ammeter direct measuring
- Product Type - 8403/6-2,5-2
- Title Product Variant Technical Data - 8403/6-2,5-2 Ammeter direct display
- WebCode - 8403B
Mechanical Data
- Accuracy class - 2.5
- Connection cross-section finely stranded max. - 6.00 mm²
- Connection cross-section solid max. - 10.00 mm²
- Connection cross-section solid min. - 2.50 mm²
- Degree of protection (IP) - IP54
- Depth - 72.000 mm
- Enclosure material - Polycarbonate
- Height - 71.200 mm
- Overload scale - 2x
- Silicone-free - No
- Terminal degree of protection (IP) - IP20
- Width - 72.000 mm
262712
Ammeters in various versions, for Ex e enclosures
Quicker comparison of measured values using externally adjustable red pointers on the device
On models with CT connection (1 A, 5 A), easy and quick measuring range assignment via retractable scale plate
Ambient Conditions
- Ambient temperature - -40 °C ... +70 °C
- Ambient temperature max. - +70 °C
- Ambient temperature min. - -40 °C
Components
- Scale - 0 - 4 / 8 A
Electrical Data
- Frequency - 0/100 Hz
- Measuring range max. - 4 A
- Measuring range min. - 0 A
- Overload capacity - 50 x IN 1 sec
- Power dissipation - 0.670 VA
- Rated operational current AC - 4.000 - 4.000 A
Explosion Protection
- Application range (zones) - 1, 2
- ATEX gas certificate - SIQ 17 ATEX 192 U
- Gas explosion protection ATEX - II 2 G Ex eb IIC Gb
- Gas explosion protection IECEx - Ex eb IIC Gb
- IECEX gas certificate - IECEx SIQ 17.0003U
General
- Functional Description - R. STAHL Series 8403 ammeters are installed in Ex e type of protection enclosures. They provide measured values for circuits which can be quickly compared with the desired values via a red pointer affixed on the outside. The devices work with a moving iron movement with accuracy class 2.5.
- Highlights - Ammeters in various versions, for Ex e enclosures Quicker comparison of measured values using externally adjustable red pointers on the device On models with CT connection (1 A, 5 A), easy and quick measuring range assignment via retractable scale plate
- Product Description - Moving iron ammeter direct measuring
- Product Type - 8403/6-4-2
- Title Product Variant Technical Data - 8403/6-4-2 Ammeter direct display
- WebCode - 8403B
Mechanical Data
- Accuracy class - 2.5
- Connection cross-section finely stranded max. - 6.00 mm²
- Connection cross-section solid max. - 10.00 mm²
- Connection cross-section solid min. - 2.50 mm²
- Degree of protection (IP) - IP54
- Depth - 72.000 mm
- Enclosure material - Polycarbonate
- Height - 71.200 mm
- Overload scale - 2x
- Silicone-free - No
- Terminal degree of protection (IP) - IP20
- Weight - 0.300 kg
- Width - 72.000 mm
262713
Ammeters in various versions, for Ex e enclosures
Quicker comparison of measured values using externally adjustable red pointers on the device
On models with CT connection (1 A, 5 A), easy and quick measuring range assignment via retractable scale plate
Ambient Conditions
- Ambient temperature - -40 °C ... +70 °C
- Ambient temperature max. - +70 °C
- Ambient temperature min. - -40 °C
Components
- Scale - without
Electrical Data
- Frequency - 0/100 Hz
- Measuring range max. - 5 A
- Measuring range min. - 0 A
- Overload capacity - 50 x IN 1 sec
- Power dissipation - 0.670 VA
- Rated operational current AC - 5.000 - 5.000 A
Explosion Protection
- Application range (zones) - 1, 2
- ATEX gas certificate - SIQ 17 ATEX 192 U
- Gas explosion protection ATEX - II 2 G Ex eb IIC Gb
- Gas explosion protection IECEx - Ex eb IIC Gb
- IECEX gas certificate - IECEx SIQ 17.0003U
General
- Functional Description - R. STAHL Series 8403 ammeters are installed in Ex e type of protection enclosures. They provide measured values for circuits which can be quickly compared with the desired values via a red pointer affixed on the outside. The devices work with a moving iron movement with accuracy class 2.5.
- Highlights - Ammeters in various versions, for Ex e enclosures Quicker comparison of measured values using externally adjustable red pointers on the device On models with CT connection (1 A, 5 A), easy and quick measuring range assignment via retractable scale plate
- Product Description - Moving iron ammeter For transducer
- Product Type - 8403/6-5T-2
- Title Product Variant Technical Data - 8403/6-5T-2 Converter Ammeter Ue=2
- WebCode - 8403B
Mechanical Data
- Accuracy class - 2.5
- Connection cross-section finely stranded max. - 6.00 mm²
- Connection cross-section solid max. - 10.00 mm²
- Connection cross-section solid min. - 2.50 mm²
- Degree of protection (IP) - IP54
- Depth - 72.000 mm
- Enclosure material - Polycarbonate
- Height - 71.200 mm
- Overload scale - 2x
- Silicone-free - No
- Terminal degree of protection (IP) - IP20
- Weight - 0.300 kg
- Width - 72.000 mm
262714
Ammeters in various versions, for Ex e enclosures
Quicker comparison of measured values using externally adjustable red pointers on the device
On models with CT connection (1 A, 5 A), easy and quick measuring range assignment via retractable scale plate
Ambient Conditions
- Ambient temperature - -40 °C ... +70 °C
- Ambient temperature max. - +70 °C
- Ambient temperature min. - -40 °C
Components
- Scale - without
Electrical Data
- Frequency - 0/100 Hz
- Measuring range max. - 5 A
- Measuring range min. - 0 A
- Overload capacity - 50 x IN 1 sec
- Power dissipation - 0.670 VA
- Rated operational current AC - 5.000 - 5.000 A
Explosion Protection
- Application range (zones) - 1, 2
- ATEX gas certificate - SIQ 17 ATEX 192 U
- Gas explosion protection ATEX - II 2 G Ex eb IIC Gb
- Gas explosion protection IECEx - Ex eb IIC Gb
- IECEX gas certificate - IECEx SIQ 17.0003U
General
- Functional Description - R. STAHL Series 8403 ammeters are installed in Ex e type of protection enclosures. They provide measured values for circuits which can be quickly compared with the desired values via a red pointer affixed on the outside. The devices work with a moving iron movement with accuracy class 2.5.
- Highlights - Ammeters in various versions, for Ex e enclosures Quicker comparison of measured values using externally adjustable red pointers on the device On models with CT connection (1 A, 5 A), easy and quick measuring range assignment via retractable scale plate
- Product Description - Moving iron ammeter For transducer
- Product Type - 8403/6-5T-5
- Title Product Variant Technical Data - 8403/6-5T-5 Converter Ammeter Ue=5
- WebCode - 8403B
Mechanical Data
- Accuracy class - 2.5
- Connection cross-section finely stranded max. - 6.00 mm²
- Connection cross-section solid max. - 10.00 mm²
- Connection cross-section solid min. - 2.50 mm²
- Degree of protection (IP) - IP54
- Depth - 72.000 mm
- Enclosure material - Polycarbonate
- Height - 71.200 mm
- Overload scale - 5x
- Silicone-free - No
- Terminal degree of protection (IP) - IP20
- Weight - 0.300 kg
- Width - 72.000 mm
262715
Ammeters in various versions, for Ex e enclosures
Quicker comparison of measured values using externally adjustable red pointers on the device
On models with CT connection (1 A, 5 A), easy and quick measuring range assignment via retractable scale plate
Ambient Conditions
- Ambient temperature - -40 °C ... +70 °C
- Ambient temperature max. - +70 °C
- Ambient temperature min. - -40 °C
Components
- Scale - 0 - 10 / 20 A
Electrical Data
- Frequency - 0/100 Hz
- Measuring range max. - 10 A
- Measuring range min. - 0 A
- Overload capacity - 50 x IN 1 sec
- Power dissipation - 0.670 VA
- Rated operational current AC - 10.000 - 10.000 A
Explosion Protection
- Application range (zones) - 1, 2
- ATEX gas certificate - SIQ 17 ATEX 192 U
- Gas explosion protection ATEX - II 2 G Ex eb mb IIC Gb
- Gas explosion protection IECEx - Ex eb mb IIC Gb
- IECEX gas certificate - IECEx SIQ 17.0003U
General
- Functional Description - R. STAHL Series 8403 ammeters are installed in Ex e type of protection enclosures. They provide measured values for circuits which can be quickly compared with the desired values via a red pointer affixed on the outside. The devices work with a moving iron movement with accuracy class 2.5.
- Highlights - Ammeters in various versions, for Ex e enclosures Quicker comparison of measured values using externally adjustable red pointers on the device On models with CT connection (1 A, 5 A), easy and quick measuring range assignment via retractable scale plate
- Product Description - Moving iron ammeter direct measuring
- Product Type - 8403/6-10-2
- Title Product Variant Technical Data - 8403/6-10-2 Ammeter direct display
- WebCode - 8403B
Mechanical Data
- Accuracy class - 2.5
- Connection cross-section finely stranded max. - 6.00 mm²
- Connection cross-section solid max. - 10.00 mm²
- Connection cross-section solid min. - 2.50 mm²
- Degree of protection (IP) - IP54
- Depth - 72.000 mm
- Enclosure material - Polycarbonate
- Height - 71.200 mm
- Overload scale - 2x
- Silicone-free - No
- Terminal degree of protection (IP) - IP20
- Weight - 0.300 kg
- Width - 72.000 mm
262716
Ammeters in various versions, for Ex e enclosures
Quicker comparison of measured values using externally adjustable red pointers on the device
On models with CT connection (1 A, 5 A), easy and quick measuring range assignment via retractable scale plate
Ambient Conditions
- Ambient temperature - -40 °C ... +70 °C
- Ambient temperature max. - +70 °C
- Ambient temperature min. - -40 °C
Components
- Scale - 0 - 15 / 30 A
Electrical Data
- Frequency - 0/100 Hz
- Measuring range max. - 15 A
- Measuring range min. - 0 A
- Overload capacity - 50 x IN 1 sec
- Power dissipation - 0.670 VA
- Rated operational current AC - 15.000 - 15.000 A
Explosion Protection
- Application range (zones) - 1, 2
- ATEX gas certificate - SIQ 17 ATEX 192 U
- Gas explosion protection ATEX - II 2 G Ex eb mb IIC Gb
- Gas explosion protection IECEx - Ex eb mb IIC Gb
- IECEX gas certificate - IECEx SIQ 17.0003U
General
- Functional Description - R. STAHL Series 8403 ammeters are installed in Ex e type of protection enclosures. They provide measured values for circuits which can be quickly compared with the desired values via a red pointer affixed on the outside. The devices work with a moving iron movement with accuracy class 2.5.
- Highlights - Ammeters in various versions, for Ex e enclosures Quicker comparison of measured values using externally adjustable red pointers on the device On models with CT connection (1 A, 5 A), easy and quick measuring range assignment via retractable scale plate
- Product Description - Moving iron ammeter direct measuring
- Product Type - 8403/6-15-2
- Title Product Variant Technical Data - 8403/6-15-2 Ammeter direct display
- WebCode - 8403B
Mechanical Data
- Accuracy class - 2.5
- Connection cross-section finely stranded max. - 6.00 mm²
- Connection cross-section solid max. - 10.00 mm²
- Connection cross-section solid min. - 4.00 mm²
- Degree of protection (IP) - IP54
- Depth - 72.000 mm
- Enclosure material - Polycarbonate
- Height - 71.200 mm
- Overload scale - 2x
- Silicone-free - No
- Terminal degree of protection (IP) - IP20
- Weight - 0.300 kg
- Width - 72.000 mm
262717
Ammeters in various versions, for Ex e enclosures
Quicker comparison of measured values using externally adjustable red pointers on the device
On models with CT connection (1 A, 5 A), easy and quick measuring range assignment via retractable scale plate
Ambient Conditions
- Ambient temperature - -40 °C ... +70 °C
- Ambient temperature max. - +70 °C
- Ambient temperature min. - -40 °C
Components
- Scale - 0 - 25 / 50 A
Electrical Data
- Frequency - 0/100 Hz
- Measuring range max. - 25 A
- Measuring range min. - 0 A
- Overload capacity - 30 x IN 1 sec
- Power dissipation - 0.670 VA
- Rated operational current AC - 25.000 - 25.000 A
Explosion Protection
- Application range (zones) - 1, 2
- ATEX gas certificate - SIQ 17 ATEX 192 U
- Gas explosion protection ATEX - II 2 G Ex eb IIC Gb
- Gas explosion protection IECEx - Ex eb IIC Gb
- IECEX gas certificate - IECEx SIQ 17.0003U
General
- Functional Description - R. STAHL Series 8403 ammeters are installed in Ex e type of protection enclosures. They provide measured values for circuits which can be quickly compared with the desired values via a red pointer affixed on the outside. The devices work with a moving iron movement with accuracy class 2.5.
- Highlights - Ammeters in various versions, for Ex e enclosures Quicker comparison of measured values using externally adjustable red pointers on the device On models with CT connection (1 A, 5 A), easy and quick measuring range assignment via retractable scale plate
- Product Description - Moving iron ammeter direct measuring
- Product Type - 8403/6-25-2
- Title Product Variant Technical Data - 8403/6-25-2 Ammeter direct display
- WebCode - 8403B
Mechanical Data
- Accuracy class - 2.5
- Connection cross-section finely stranded max. - 6.00 mm²
- Connection cross-section solid max. - 10.00 mm²
- Connection cross-section solid min. - 6.00 mm²
- Degree of protection (IP) - IP54
- Depth - 72.000 mm
- Enclosure material - Polycarbonate
- Height - 71.200 mm
- Overload scale - 2x
- Silicone-free - No
- Terminal degree of protection (IP) - IP20
- Weight - 0.300 kg
- Width - 72.000 mm
267132
Ammeters in various versions, for Ex e enclosures
Quicker comparison of measured values using externally adjustable red pointers on the device
On models with CT connection (1 A, 5 A), easy and quick measuring range assignment via retractable scale plate
Ambient Conditions
- Ambient temperature - -40 °C ... +70 °C
- Ambient temperature max. - +70 °C
- Ambient temperature min. - -40 °C
Components
- Scale - 0 - 100 / 200%
Electrical Data
- Frequency - 0/100 Hz
- Measuring range max. - 1 A
- Measuring range min. - 0 A
- Overload capacity - 50 x IN 1 sec
- Power dissipation - 0.670 VA
- Rated operational current AC - 1.000 - 1.000 A
Explosion Protection
- Application range (zones) - 1, 2
- ATEX gas certificate - SIQ 17 ATEX 192 U
- Gas explosion protection ATEX - II 2 G Ex eb IIC Gb
- Gas explosion protection IECEx - Ex eb IIC Gb
- IECEX gas certificate - IECEx SIQ 17.0003U
General
- Functional Description - R. STAHL Series 8403 ammeters are installed in Ex e type of protection enclosures. They provide measured values for circuits which can be quickly compared with the desired values via a red pointer affixed on the outside. The devices work with a moving iron movement with accuracy class 2.5.
- Highlights - Ammeters in various versions, for Ex e enclosures Quicker comparison of measured values using externally adjustable red pointers on the device On models with CT connection (1 A, 5 A), easy and quick measuring range assignment via retractable scale plate
- Product Description - Moving iron ammeter For transducer
- Product Type - 8403/6-1T-2
- Title Product Variant Technical Data - 8403/6-1T-2 Converter w.scale 0-100/200%
- WebCode - 8403B
Mechanical Data
- Accuracy class - 2.5
- Connection cross-section finely stranded max. - 6.00 mm²
- Connection cross-section solid max. - 10.00 mm²
- Connection cross-section solid min. - 2.50 mm²
- Degree of protection (IP) - IP54
- Depth - 72.000 mm
- Enclosure material - Polycarbonate
- Height - 71.200 mm
- Overload scale - 2x
- Silicone-free - No
- Terminal degree of protection (IP) - IP20
- Weight - 0.210 kg
- Width - 72.000 mm
1 - 11 of 11 Part Numbers