Yodify Product Library
Instantly add the Ammeter Series 8403 and 50,000+ more product series to your store or catalog  
Book Your Demo and See How
or create your store

Ammeter Series 8403

Brand: R. STAHL AG

R. STAHL Series 8403 ammeters are installed in Ex e type of protection enclosures. They provide measured values for circuits which can be quickly compared with the desired values via a red pointer affixed on the outside. The devices work with a moving iron movement with accuracy class 2.5.
Features
  • Ammeters in various versions, for Ex e enclosures
  • Quicker comparison of measured values using externally adjustable red pointers on the device
  • On models with CT connection (1 A, 5 A), easy and quick measuring range assignment via retractable scale plate

1 - 11 of 11 Part Numbers
262688
262688
R. STAHL Moving Iron Ammeter Direct Measuring
Ammeters in various versions, for Ex e enclosures

Quicker comparison of measured values using externally adjustable red pointers on the device

On models with CT connection (1 A, 5 A), easy and quick measuring range assignment via retractable scale plate

Ambient Conditions

  • Ambient temperature - -40 °C ... +70 °C
  • Ambient temperature max. - +70 °C
  • Ambient temperature min. - -40 °C

Components

  • Scale - 0 - 1 / 2 A

Electrical Data

  • Frequency - 0/100 Hz
  • Measuring range max. - 1 A
  • Measuring range min. - 0 A
  • Overload capacity - 50 x IN 1 sec
  • Power dissipation - 0.670 VA
  • Rated operational current AC - 1.000 - 1.000 A

Explosion Protection

  • Application range (zones) - 1, 2
  • ATEX gas certificate - SIQ 17 ATEX 192 U
  • Gas explosion protection ATEX - II 2 G Ex eb IIC Gb
  • Gas explosion protection IECEx - Ex eb IIC Gb
  • IECEX gas certificate - IECEx SIQ 17.0003U

General

  • Functional Description - R. STAHL Series 8403 ammeters are installed in Ex e type of protection enclosures. They provide measured values for circuits which can be quickly compared with the desired values via a red pointer affixed on the outside. The devices work with a moving iron movement with accuracy class 2.5.
  • Highlights - Ammeters in various versions, for Ex e enclosures Quicker comparison of measured values using externally adjustable red pointers on the device On models with CT connection (1 A, 5 A), easy and quick measuring range assignment via retractable scale plate
  • Product Description - Moving iron ammeter direct measuring
  • Product Type - 8403/6-1-2
  • Title Product Variant Technical Data - 8403/6-1-2 Ammeter direct display
  • WebCode - 8403B

Mechanical Data

  • Accuracy class - 2.5
  • Connection cross-section finely stranded max. - 6.00 mm²
  • Connection cross-section solid max. - 10.00 mm²
  • Connection cross-section solid min. - 2.50 mm²
  • Degree of protection (IP) - IP54
  • Depth - 72.000 mm
  • Enclosure material - Polycarbonate
  • Height - 71.200 mm
  • Overload scale - 2x
  • Silicone-free - No
  • Terminal degree of protection (IP) - IP20
  • Weight - 0.300 kg
  • Width - 72.000 mm
262689
262689
R. STAHL Moving Iron Ammeter for Transducer
Ammeters in various versions, for Ex e enclosures

Quicker comparison of measured values using externally adjustable red pointers on the device

On models with CT connection (1 A, 5 A), easy and quick measuring range assignment via retractable scale plate

Ambient Conditions

  • Ambient temperature - -40 °C ... +70 °C
  • Ambient temperature max. - +70 °C
  • Ambient temperature min. - -40 °C

Components

  • Scale - without

Electrical Data

  • Frequency - 0/100 Hz
  • Measuring range max. - 1 A
  • Measuring range min. - 0 A
  • Overload capacity - 50 x IN 1 sec
  • Power dissipation - 0.670 VA
  • Rated operational current AC - 1.000 - 1.000 A

Explosion Protection

  • Application range (zones) - 1, 2
  • ATEX gas certificate - SIQ 17 ATEX 192 U
  • Gas explosion protection ATEX - II 2 G Ex eb IIC Gb
  • Gas explosion protection IECEx - Ex eb IIC Gb
  • IECEX gas certificate - IECEx SIQ 17.0003U

General

  • Functional Description - R. STAHL Series 8403 ammeters are installed in Ex e type of protection enclosures. They provide measured values for circuits which can be quickly compared with the desired values via a red pointer affixed on the outside. The devices work with a moving iron movement with accuracy class 2.5.
  • Highlights - Ammeters in various versions, for Ex e enclosures Quicker comparison of measured values using externally adjustable red pointers on the device On models with CT connection (1 A, 5 A), easy and quick measuring range assignment via retractable scale plate
  • Product Description - Moving iron ammeter For transducer
  • Product Type - 8403/6-1T-2
  • Title Product Variant Technical Data - 8403/6-1T-2 Converter Ammeter Ue=2
  • WebCode - 8403B

Mechanical Data

  • Accuracy class - 2.5
  • Connection cross-section finely stranded max. - 6.00 mm²
  • Connection cross-section solid max. - 10.00 mm²
  • Connection cross-section solid min. - 2.50 mm²
  • Degree of protection (IP) - IP54
  • Depth - 72.000 mm
  • Enclosure material - Polycarbonate
  • Height - 71.200 mm
  • Overload scale - 2x
  • Silicone-free - No
  • Terminal degree of protection (IP) - IP20
  • Weight - 0.300 kg
  • Width - 72.000 mm
262690
262690
R. STAHL Moving Iron Ammeter for Transducer
Ammeters in various versions, for Ex e enclosures

Quicker comparison of measured values using externally adjustable red pointers on the device

On models with CT connection (1 A, 5 A), easy and quick measuring range assignment via retractable scale plate

Ambient Conditions

  • Ambient temperature - -40 °C ... +70 °C
  • Ambient temperature max. - +70 °C
  • Ambient temperature min. - -40 °C

Components

  • Scale - without

Electrical Data

  • Frequency - 0/100 Hz
  • Measuring range max. - 1 A
  • Measuring range min. - 0 A
  • Overload capacity - 50 x IN 1 sec
  • Power dissipation - 0.670 VA
  • Rated operational current AC - 1.000 - 1.000 A

Explosion Protection

  • Application range (zones) - 1, 2
  • ATEX gas certificate - SIQ 17 ATEX 192 U
  • Gas explosion protection ATEX - II 2 G Ex eb IIC Gb
  • Gas explosion protection IECEx - Ex eb IIC Gb
  • IECEX gas certificate - IECEx SIQ 17.0003U

General

  • Functional Description - R. STAHL Series 8403 ammeters are installed in Ex e type of protection enclosures. They provide measured values for circuits which can be quickly compared with the desired values via a red pointer affixed on the outside. The devices work with a moving iron movement with accuracy class 2.5.
  • Highlights - Ammeters in various versions, for Ex e enclosures Quicker comparison of measured values using externally adjustable red pointers on the device On models with CT connection (1 A, 5 A), easy and quick measuring range assignment via retractable scale plate
  • Product Description - Moving iron ammeter For transducer
  • Product Type - 8403/6-1T-5
  • Title Product Variant Technical Data - 8403/6-1T-5 Converter Ammeter Ue=5
  • WebCode - 8403B

Mechanical Data

  • Accuracy class - 2.5
  • Connection cross-section finely stranded max. - 6.00 mm²
  • Connection cross-section solid max. - 10.00 mm²
  • Connection cross-section solid min. - 2.50 mm²
  • Degree of protection (IP) - IP54
  • Depth - 72.000 mm
  • Enclosure material - Polycarbonate
  • Height - 71.200 mm
  • Overload scale - 5x
  • Silicone-free - No
  • Terminal degree of protection (IP) - IP20
  • Weight - 0.300 kg
  • Width - 72.000 mm
262711
262711
R. STAHL Moving Iron Ammeter Direct Measuring
Ammeters in various versions, for Ex e enclosures

Quicker comparison of measured values using externally adjustable red pointers on the device

On models with CT connection (1 A, 5 A), easy and quick measuring range assignment via retractable scale plate

Ambient Conditions

  • Ambient temperature - -40 °C ... +70 °C
  • Ambient temperature max. - +70 °C
  • Ambient temperature min. - -40 °C

Components

  • Scale - 0 - 2.5 / 5 A

Electrical Data

  • Frequency - 0/100 Hz
  • Measuring range max. - 2,5 A
  • Measuring range min. - 0 A
  • Overload capacity - 50 x IN 1 sec
  • Power dissipation - 0.670 VA
  • Rated operational current AC - 2.500 - 2.500 A

Explosion Protection

  • Application range (zones) - 1, 2
  • ATEX gas certificate - SIQ 17 ATEX 192 U
  • Gas explosion protection ATEX - II 2 G Ex eb IIC Gb
  • Gas explosion protection IECEx - Ex eb IIC Gb
  • IECEX gas certificate - IECEx SIQ 17.0003U

General

  • Functional Description - R. STAHL Series 8403 ammeters are installed in Ex e type of protection enclosures. They provide measured values for circuits which can be quickly compared with the desired values via a red pointer affixed on the outside. The devices work with a moving iron movement with accuracy class 2.5.
  • Highlights - Ammeters in various versions, for Ex e enclosures Quicker comparison of measured values using externally adjustable red pointers on the device On models with CT connection (1 A, 5 A), easy and quick measuring range assignment via retractable scale plate
  • Product Description - Moving iron ammeter direct measuring
  • Product Type - 8403/6-2,5-2
  • Title Product Variant Technical Data - 8403/6-2,5-2 Ammeter direct display
  • WebCode - 8403B

Mechanical Data

  • Accuracy class - 2.5
  • Connection cross-section finely stranded max. - 6.00 mm²
  • Connection cross-section solid max. - 10.00 mm²
  • Connection cross-section solid min. - 2.50 mm²
  • Degree of protection (IP) - IP54
  • Depth - 72.000 mm
  • Enclosure material - Polycarbonate
  • Height - 71.200 mm
  • Overload scale - 2x
  • Silicone-free - No
  • Terminal degree of protection (IP) - IP20
  • Width - 72.000 mm
262712
262712
R. STAHL Moving Iron Ammeter Direct Measuring
Ammeters in various versions, for Ex e enclosures

Quicker comparison of measured values using externally adjustable red pointers on the device

On models with CT connection (1 A, 5 A), easy and quick measuring range assignment via retractable scale plate

Ambient Conditions

  • Ambient temperature - -40 °C ... +70 °C
  • Ambient temperature max. - +70 °C
  • Ambient temperature min. - -40 °C

Components

  • Scale - 0 - 4 / 8 A

Electrical Data

  • Frequency - 0/100 Hz
  • Measuring range max. - 4 A
  • Measuring range min. - 0 A
  • Overload capacity - 50 x IN 1 sec
  • Power dissipation - 0.670 VA
  • Rated operational current AC - 4.000 - 4.000 A

Explosion Protection

  • Application range (zones) - 1, 2
  • ATEX gas certificate - SIQ 17 ATEX 192 U
  • Gas explosion protection ATEX - II 2 G Ex eb IIC Gb
  • Gas explosion protection IECEx - Ex eb IIC Gb
  • IECEX gas certificate - IECEx SIQ 17.0003U

General

  • Functional Description - R. STAHL Series 8403 ammeters are installed in Ex e type of protection enclosures. They provide measured values for circuits which can be quickly compared with the desired values via a red pointer affixed on the outside. The devices work with a moving iron movement with accuracy class 2.5.
  • Highlights - Ammeters in various versions, for Ex e enclosures Quicker comparison of measured values using externally adjustable red pointers on the device On models with CT connection (1 A, 5 A), easy and quick measuring range assignment via retractable scale plate
  • Product Description - Moving iron ammeter direct measuring
  • Product Type - 8403/6-4-2
  • Title Product Variant Technical Data - 8403/6-4-2 Ammeter direct display
  • WebCode - 8403B

Mechanical Data

  • Accuracy class - 2.5
  • Connection cross-section finely stranded max. - 6.00 mm²
  • Connection cross-section solid max. - 10.00 mm²
  • Connection cross-section solid min. - 2.50 mm²
  • Degree of protection (IP) - IP54
  • Depth - 72.000 mm
  • Enclosure material - Polycarbonate
  • Height - 71.200 mm
  • Overload scale - 2x
  • Silicone-free - No
  • Terminal degree of protection (IP) - IP20
  • Weight - 0.300 kg
  • Width - 72.000 mm
262713
262713
R. STAHL Moving Iron Ammeter for Transducer
Ammeters in various versions, for Ex e enclosures

Quicker comparison of measured values using externally adjustable red pointers on the device

On models with CT connection (1 A, 5 A), easy and quick measuring range assignment via retractable scale plate

Ambient Conditions

  • Ambient temperature - -40 °C ... +70 °C
  • Ambient temperature max. - +70 °C
  • Ambient temperature min. - -40 °C

Components

  • Scale - without

Electrical Data

  • Frequency - 0/100 Hz
  • Measuring range max. - 5 A
  • Measuring range min. - 0 A
  • Overload capacity - 50 x IN 1 sec
  • Power dissipation - 0.670 VA
  • Rated operational current AC - 5.000 - 5.000 A

Explosion Protection

  • Application range (zones) - 1, 2
  • ATEX gas certificate - SIQ 17 ATEX 192 U
  • Gas explosion protection ATEX - II 2 G Ex eb IIC Gb
  • Gas explosion protection IECEx - Ex eb IIC Gb
  • IECEX gas certificate - IECEx SIQ 17.0003U

General

  • Functional Description - R. STAHL Series 8403 ammeters are installed in Ex e type of protection enclosures. They provide measured values for circuits which can be quickly compared with the desired values via a red pointer affixed on the outside. The devices work with a moving iron movement with accuracy class 2.5.
  • Highlights - Ammeters in various versions, for Ex e enclosures Quicker comparison of measured values using externally adjustable red pointers on the device On models with CT connection (1 A, 5 A), easy and quick measuring range assignment via retractable scale plate
  • Product Description - Moving iron ammeter For transducer
  • Product Type - 8403/6-5T-2
  • Title Product Variant Technical Data - 8403/6-5T-2 Converter Ammeter Ue=2
  • WebCode - 8403B

Mechanical Data

  • Accuracy class - 2.5
  • Connection cross-section finely stranded max. - 6.00 mm²
  • Connection cross-section solid max. - 10.00 mm²
  • Connection cross-section solid min. - 2.50 mm²
  • Degree of protection (IP) - IP54
  • Depth - 72.000 mm
  • Enclosure material - Polycarbonate
  • Height - 71.200 mm
  • Overload scale - 2x
  • Silicone-free - No
  • Terminal degree of protection (IP) - IP20
  • Weight - 0.300 kg
  • Width - 72.000 mm
262714
262714
R. STAHL Moving Iron Ammeter for Transducer
Ammeters in various versions, for Ex e enclosures

Quicker comparison of measured values using externally adjustable red pointers on the device

On models with CT connection (1 A, 5 A), easy and quick measuring range assignment via retractable scale plate

Ambient Conditions

  • Ambient temperature - -40 °C ... +70 °C
  • Ambient temperature max. - +70 °C
  • Ambient temperature min. - -40 °C

Components

  • Scale - without

Electrical Data

  • Frequency - 0/100 Hz
  • Measuring range max. - 5 A
  • Measuring range min. - 0 A
  • Overload capacity - 50 x IN 1 sec
  • Power dissipation - 0.670 VA
  • Rated operational current AC - 5.000 - 5.000 A

Explosion Protection

  • Application range (zones) - 1, 2
  • ATEX gas certificate - SIQ 17 ATEX 192 U
  • Gas explosion protection ATEX - II 2 G Ex eb IIC Gb
  • Gas explosion protection IECEx - Ex eb IIC Gb
  • IECEX gas certificate - IECEx SIQ 17.0003U

General

  • Functional Description - R. STAHL Series 8403 ammeters are installed in Ex e type of protection enclosures. They provide measured values for circuits which can be quickly compared with the desired values via a red pointer affixed on the outside. The devices work with a moving iron movement with accuracy class 2.5.
  • Highlights - Ammeters in various versions, for Ex e enclosures Quicker comparison of measured values using externally adjustable red pointers on the device On models with CT connection (1 A, 5 A), easy and quick measuring range assignment via retractable scale plate
  • Product Description - Moving iron ammeter For transducer
  • Product Type - 8403/6-5T-5
  • Title Product Variant Technical Data - 8403/6-5T-5 Converter Ammeter Ue=5
  • WebCode - 8403B

Mechanical Data

  • Accuracy class - 2.5
  • Connection cross-section finely stranded max. - 6.00 mm²
  • Connection cross-section solid max. - 10.00 mm²
  • Connection cross-section solid min. - 2.50 mm²
  • Degree of protection (IP) - IP54
  • Depth - 72.000 mm
  • Enclosure material - Polycarbonate
  • Height - 71.200 mm
  • Overload scale - 5x
  • Silicone-free - No
  • Terminal degree of protection (IP) - IP20
  • Weight - 0.300 kg
  • Width - 72.000 mm
262715
262715
R. STAHL Moving Iron Ammeter Direct Measuring
Ammeters in various versions, for Ex e enclosures

Quicker comparison of measured values using externally adjustable red pointers on the device

On models with CT connection (1 A, 5 A), easy and quick measuring range assignment via retractable scale plate

Ambient Conditions

  • Ambient temperature - -40 °C ... +70 °C
  • Ambient temperature max. - +70 °C
  • Ambient temperature min. - -40 °C

Components

  • Scale - 0 - 10 / 20 A

Electrical Data

  • Frequency - 0/100 Hz
  • Measuring range max. - 10 A
  • Measuring range min. - 0 A
  • Overload capacity - 50 x IN 1 sec
  • Power dissipation - 0.670 VA
  • Rated operational current AC - 10.000 - 10.000 A

Explosion Protection

  • Application range (zones) - 1, 2
  • ATEX gas certificate - SIQ 17 ATEX 192 U
  • Gas explosion protection ATEX - II 2 G Ex eb mb IIC Gb
  • Gas explosion protection IECEx - Ex eb mb IIC Gb
  • IECEX gas certificate - IECEx SIQ 17.0003U

General

  • Functional Description - R. STAHL Series 8403 ammeters are installed in Ex e type of protection enclosures. They provide measured values for circuits which can be quickly compared with the desired values via a red pointer affixed on the outside. The devices work with a moving iron movement with accuracy class 2.5.
  • Highlights - Ammeters in various versions, for Ex e enclosures Quicker comparison of measured values using externally adjustable red pointers on the device On models with CT connection (1 A, 5 A), easy and quick measuring range assignment via retractable scale plate
  • Product Description - Moving iron ammeter direct measuring
  • Product Type - 8403/6-10-2
  • Title Product Variant Technical Data - 8403/6-10-2 Ammeter direct display
  • WebCode - 8403B

Mechanical Data

  • Accuracy class - 2.5
  • Connection cross-section finely stranded max. - 6.00 mm²
  • Connection cross-section solid max. - 10.00 mm²
  • Connection cross-section solid min. - 2.50 mm²
  • Degree of protection (IP) - IP54
  • Depth - 72.000 mm
  • Enclosure material - Polycarbonate
  • Height - 71.200 mm
  • Overload scale - 2x
  • Silicone-free - No
  • Terminal degree of protection (IP) - IP20
  • Weight - 0.300 kg
  • Width - 72.000 mm
262716
262716
R. STAHL Moving Iron Ammeter Direct Measuring
Ammeters in various versions, for Ex e enclosures

Quicker comparison of measured values using externally adjustable red pointers on the device

On models with CT connection (1 A, 5 A), easy and quick measuring range assignment via retractable scale plate

Ambient Conditions

  • Ambient temperature - -40 °C ... +70 °C
  • Ambient temperature max. - +70 °C
  • Ambient temperature min. - -40 °C

Components

  • Scale - 0 - 15 / 30 A

Electrical Data

  • Frequency - 0/100 Hz
  • Measuring range max. - 15 A
  • Measuring range min. - 0 A
  • Overload capacity - 50 x IN 1 sec
  • Power dissipation - 0.670 VA
  • Rated operational current AC - 15.000 - 15.000 A

Explosion Protection

  • Application range (zones) - 1, 2
  • ATEX gas certificate - SIQ 17 ATEX 192 U
  • Gas explosion protection ATEX - II 2 G Ex eb mb IIC Gb
  • Gas explosion protection IECEx - Ex eb mb IIC Gb
  • IECEX gas certificate - IECEx SIQ 17.0003U

General

  • Functional Description - R. STAHL Series 8403 ammeters are installed in Ex e type of protection enclosures. They provide measured values for circuits which can be quickly compared with the desired values via a red pointer affixed on the outside. The devices work with a moving iron movement with accuracy class 2.5.
  • Highlights - Ammeters in various versions, for Ex e enclosures Quicker comparison of measured values using externally adjustable red pointers on the device On models with CT connection (1 A, 5 A), easy and quick measuring range assignment via retractable scale plate
  • Product Description - Moving iron ammeter direct measuring
  • Product Type - 8403/6-15-2
  • Title Product Variant Technical Data - 8403/6-15-2 Ammeter direct display
  • WebCode - 8403B

Mechanical Data

  • Accuracy class - 2.5
  • Connection cross-section finely stranded max. - 6.00 mm²
  • Connection cross-section solid max. - 10.00 mm²
  • Connection cross-section solid min. - 4.00 mm²
  • Degree of protection (IP) - IP54
  • Depth - 72.000 mm
  • Enclosure material - Polycarbonate
  • Height - 71.200 mm
  • Overload scale - 2x
  • Silicone-free - No
  • Terminal degree of protection (IP) - IP20
  • Weight - 0.300 kg
  • Width - 72.000 mm
262717
262717
R. STAHL Moving Iron Ammeter Direct Measuring
Ammeters in various versions, for Ex e enclosures

Quicker comparison of measured values using externally adjustable red pointers on the device

On models with CT connection (1 A, 5 A), easy and quick measuring range assignment via retractable scale plate

Ambient Conditions

  • Ambient temperature - -40 °C ... +70 °C
  • Ambient temperature max. - +70 °C
  • Ambient temperature min. - -40 °C

Components

  • Scale - 0 - 25 / 50 A

Electrical Data

  • Frequency - 0/100 Hz
  • Measuring range max. - 25 A
  • Measuring range min. - 0 A
  • Overload capacity - 30 x IN 1 sec
  • Power dissipation - 0.670 VA
  • Rated operational current AC - 25.000 - 25.000 A

Explosion Protection

  • Application range (zones) - 1, 2
  • ATEX gas certificate - SIQ 17 ATEX 192 U
  • Gas explosion protection ATEX - II 2 G Ex eb IIC Gb
  • Gas explosion protection IECEx - Ex eb IIC Gb
  • IECEX gas certificate - IECEx SIQ 17.0003U

General

  • Functional Description - R. STAHL Series 8403 ammeters are installed in Ex e type of protection enclosures. They provide measured values for circuits which can be quickly compared with the desired values via a red pointer affixed on the outside. The devices work with a moving iron movement with accuracy class 2.5.
  • Highlights - Ammeters in various versions, for Ex e enclosures Quicker comparison of measured values using externally adjustable red pointers on the device On models with CT connection (1 A, 5 A), easy and quick measuring range assignment via retractable scale plate
  • Product Description - Moving iron ammeter direct measuring
  • Product Type - 8403/6-25-2
  • Title Product Variant Technical Data - 8403/6-25-2 Ammeter direct display
  • WebCode - 8403B

Mechanical Data

  • Accuracy class - 2.5
  • Connection cross-section finely stranded max. - 6.00 mm²
  • Connection cross-section solid max. - 10.00 mm²
  • Connection cross-section solid min. - 6.00 mm²
  • Degree of protection (IP) - IP54
  • Depth - 72.000 mm
  • Enclosure material - Polycarbonate
  • Height - 71.200 mm
  • Overload scale - 2x
  • Silicone-free - No
  • Terminal degree of protection (IP) - IP20
  • Weight - 0.300 kg
  • Width - 72.000 mm
267132
267132
R. STAHL Moving Iron Ammeter for Transducer
Ammeters in various versions, for Ex e enclosures

Quicker comparison of measured values using externally adjustable red pointers on the device

On models with CT connection (1 A, 5 A), easy and quick measuring range assignment via retractable scale plate

Ambient Conditions

  • Ambient temperature - -40 °C ... +70 °C
  • Ambient temperature max. - +70 °C
  • Ambient temperature min. - -40 °C

Components

  • Scale - 0 - 100 / 200%

Electrical Data

  • Frequency - 0/100 Hz
  • Measuring range max. - 1 A
  • Measuring range min. - 0 A
  • Overload capacity - 50 x IN 1 sec
  • Power dissipation - 0.670 VA
  • Rated operational current AC - 1.000 - 1.000 A

Explosion Protection

  • Application range (zones) - 1, 2
  • ATEX gas certificate - SIQ 17 ATEX 192 U
  • Gas explosion protection ATEX - II 2 G Ex eb IIC Gb
  • Gas explosion protection IECEx - Ex eb IIC Gb
  • IECEX gas certificate - IECEx SIQ 17.0003U

General

  • Functional Description - R. STAHL Series 8403 ammeters are installed in Ex e type of protection enclosures. They provide measured values for circuits which can be quickly compared with the desired values via a red pointer affixed on the outside. The devices work with a moving iron movement with accuracy class 2.5.
  • Highlights - Ammeters in various versions, for Ex e enclosures Quicker comparison of measured values using externally adjustable red pointers on the device On models with CT connection (1 A, 5 A), easy and quick measuring range assignment via retractable scale plate
  • Product Description - Moving iron ammeter For transducer
  • Product Type - 8403/6-1T-2
  • Title Product Variant Technical Data - 8403/6-1T-2 Converter w.scale 0-100/200%
  • WebCode - 8403B

Mechanical Data

  • Accuracy class - 2.5
  • Connection cross-section finely stranded max. - 6.00 mm²
  • Connection cross-section solid max. - 10.00 mm²
  • Connection cross-section solid min. - 2.50 mm²
  • Degree of protection (IP) - IP54
  • Depth - 72.000 mm
  • Enclosure material - Polycarbonate
  • Height - 71.200 mm
  • Overload scale - 2x
  • Silicone-free - No
  • Terminal degree of protection (IP) - IP20
  • Weight - 0.210 kg
  • Width - 72.000 mm
1 - 11 of 11 Part Numbers
Instantly populate your store or catalog 
CREATE YOUR SITE
or book a demo with the Yodify Team
show more