Yodify Product Library
Instantly add the Series 616WL Differential Pressure Transmitter and 50,000+ more product series to your store or catalog  
Book Your Demo and See How
or create your store

Series 616WL Differential Pressure Transmitter

Brand: Dwyer Instruments, LLC

The SERIES 616WL Differential Pressure Transmitter senses very low pressures of air and non-combustible, compatible gases and sends a standard 4-20 mA output signal.

All models, including those featuring the 3 digit LCD digital read-out, are factory calibrated to specific ranges as listed in the chart below. 

Positive, negative and differential pressures can be measured within a full span accuracy of ±0.50%. This weatherproof unit is enclosed in a polycarbonate case, designed to meet (IP66/NEMA 4X). Internal digital push button zero and span allow for quick and simple field calibration.
Features
  • NEMA 4X rated enclosure provides protection in harsh environments permitting outdoor monitoring or in areas where dust and particulate matter exists
  • Easy to read LCD display provides immediate local alerts allowing corrective action to be taken quicker to eliminate the problem from becoming widespread
  • Zero and span controls provides easy calibration checks and shorter installation time to get device running and monitoring
  • High precision accuracy at low pressure ranges provides exceptional accuracy for insuring tight-control and minimizing costly out of specification conditions

1 - 12 of 16 Part Numbers
616WL-12-LCD
616WL-12-LCD
DWYER Differential Pressure Transmitter, Range 0.25-0-0.25" W.C., NEMA 4X Housing, with LCD Display.
  • Pressure Range - Inches WC: 0 to ± 0.25
  • Certificates - No Additional Certifications
616WL-12-LCD-NIST
616WL-12-LCD-NIST
  • Pressure Range - Inches WC: 0 to ± 0.25
  • Certificates - NIST Traceable Calibration Certificate
616WL-14-LCD
616WL-14-LCD
DWYER Differential Pressure Transmitter, Range 1-0-1" W.C., NEMA 4X Housing, with LCD Display.
  • Pressure Range - Inches WC: 0 to ± 1
  • Certificates - No Additional Certifications
616WL-14-LCD-NIST
616WL-14-LCD-NIST
  • Pressure Range - Inches WC: 0 to ± 1
  • Certificates - NIST Traceable Calibration Certificate
616WL-2-LCD
616WL-2-LCD
DWYER Differential Pressure Transmitter, Range 0-.25" W.C., NEMA 4X Housing, with LCD Display.
  • Pressure Range - Inches WC: 0 to 0.25
  • Certificates - No Additional Certifications
616WL-2-LCD-NIST
616WL-2-LCD-NIST
  • Pressure Range - Inches WC: 0 to 0.25
  • Certificates - NIST Traceable Calibration Certificate
616WL-22-LCD
616WL-22-LCD
DWYER Differential Pressure Transmitter, Range 0-60 Pa, NEMA 4X Housing, with LCD Display.
  • Pressure Range - Inches WC: 0 to 60
  • Certificates - No Additional Certifications
616WL-22-LCD-NIST
616WL-22-LCD-NIST
  • Pressure Range - Inches WC: 0 to 60
  • Certificates - NIST Traceable Calibration Certificate
616WL-25-LCD
616WL-25-LCD
DWYER Differential Pressure Transmitter, Range 0-250 Pa, NEMA 4X Housing, with LCD Display.
  • Pressure Range - Inches WC: 0 to 250
  • Certificates - No Additional Certifications
616WL-25-LCD-NIST
616WL-25-LCD-NIST
  • Pressure Range - Inches WC: 0 to 250
  • Certificates - NIST Traceable Calibration Certificate
616WL-32-LCD
616WL-32-LCD
DWYER Differential Pressure Transmitter, Range 60-0-60 Pa, NEMA 4X Housing, with LCD Display.
  • Pressure Range - Inches WC: 0 to ± 60
  • Certificates - No Additional Certifications
616WL-32-LCD-NIST
616WL-32-LCD-NIST
  • Pressure Range - Inches WC: 0 to ± 60
  • Certificates - NIST Traceable Calibration Certificate
1 - 12 of 16 Part Numbers

Specifications

Accuracy

  • ± 0.5 % of Full Scale, Display Accuracy ± 0.5 %

Approvals & Certifications

  • CE

Compensated Temperature

  • -6.67° to 48.9° C (20° to 120° F)

Consumption

  • DC: 38 mA - Max.

Electrical Connectors

  • Screw Typical Terminal Block

Environmental Protection

  • IP66
  • NEMA 4X

Loop Resistance

  • DC: 0 to 900 ohms, Max.

Maximum System Pressure

  • psig: 2 to 4

Media

  • Air
  • Non-Combustible, Compatible Gases

NACE & NIST

  • NIST Traceable Calibration Certificate

Output

  • 4-20 mA

Power Requirement

  • 12-30 Vdc (2-Wire)

Pressure Range

  • Inches WC: 0 to 1
  • Pa: 0 to 250

Process Connection Material

  • Rubber
  • Vinyl Tubing

Sensor Orientation

  • Vertical

Span & Zero Adjustments

  • Digital Push Button

Stability

  • ± 1 % of Full Scale Per Year

Temperature Effect

  • ± 0.02 % of Full Scale/°F
  • 0.036 % of Full Scale/°C

Temperature Range

  • -17.8° to 60° C (0° to 140° F)

Tube Connection

  • 3/16” Tube
  • Dual Size to Fit 1/8” & 3/16” I.D. Rubber or Vinyl Tubing

  • Low pressure applications
  • Outdoor HVAC
  • Dust collection
  • Roof-top equipment
Instantly populate your store or catalog 
CREATE YOUR SITE
or book a demo with the Yodify Team
show more