Yodify Product Library
Instantly add the OX-TRAN 2/40 OTR Analyzer for Packages and 50,000+ more product series to your store or catalog  
Book Your Demo and See How
or create your store

OX-TRAN 2/40 OTR Analyzer for Packages

Brand: MOCON

The OX-TRAN 2/40 series is the next evolution in whole package testing for Oxygen Transmission Rate (OTR).

These advanced analyzers integrate MOCON’s proven OTR analyzer system with a precision environmental chamber to elevate package testing to the next level in accuracy, repeatability and ease of use.

With special functions designed for oxygen barrier testing, they greatly reduce overall test time while the new package testing cartridge designs offer simple sample preparation and improved repeatability of test results.

They feature 4 independent cells with changeable test cartridges that allow a wide variety of package sizes and types to be easily and accurately tested, many without the use of epoxy. 

High Accuracy Package Testing
  • Patented Coulox® sensor is the only absolute Coulometric sensor on market, never requiring calibration
  • Low level detection available down to 25 x 10⁷ cc/(package x day) (10X model)
  • Fully automated temperature, flow and RH controls simplify testing and provide unparalleled repeatability
Ease of Use
  • Removable test cartridges allow fast sample exchange with the touch of 1 button
  • Different cartridge options designed to make mounting and testing for a wide variety of package types simple, accurate, and repeatable 
  • Advanced automatic purge and conditioning capability for packages reduce overall testing time 
  • Touch screen interface allows complete control and monitoring of all testing variables throughout the testing process
The Ox-Tran 2/40 series of package testing analyzers can test the Oxygen Transmission Rate (OTR) on both films and packages from low to high barriers.

They use MOCON’s patented Coulox absolute (intrinsic) coulometric sensor requires no calibration and is the base for the ASTM standard D3985.

The 4 independent test cells can perform different tests in parallel under precisely controlled environmental conditions from 10°C to 50°C and a range of dry to 90% humidity in the chamber.

A variety of testing cartridges are available to easily and accurately test trays, bottles, flexible containers, pouches, cups, pods, caps, closures, cartons, films and just about any other type of sample.

Custom designed cartridges are also available to simplify sample preparation and improve testing repeatability.

MODELS:

This family of versatile instruments has 3 models each having a different factor of lower detection limits.
  • H Model (common barriers) - detection range from 0.00025 to 1 cc/package x day
  • L Model (high barriers) - is able to achieve a factor of 10 lower than the H Model providing a range from 0.000025 to 1 cc/package x day
  • 10X Model (ultra-high barriers) – the lowest detection level at 100 times lower than the H model providing a range from 0.0000025 to 1 cc/package x day.
For more than 25 years, MOCON’s OX-TRAN series of instruments have been the most trusted and longest lasting on the market.

The OX-TRAN 2/40 series is the newest option available that takes whole package testing to the next level allowing brand owners and packaging service providers the ability to reliably test the shelf life of their finished packages.

It is the perfect complement to any testing laboratory who frequently tests complete.

The OX-TRAN 2/40 series is the next evolution in whole package testing for Oxygen Transmission Rate in controlled conditions.
Features
  • Variety of Package and Film Test Cartridges
    • Easy sample prep on the benchtop, many without epoxy
    • One button quick release and loading
    • Single use mounting foil plates simplifies package mounting
    • Specialized cartridge options save time and improve test repeatability
  • Automated Control Features
    • Flow, Temp, & RH control
    • Test Process Development and Recommendations
    • Programmable Test Sequencing
    • Test report printing and export
    • Sensor Protection
  • Touchscreen Interface
    • Intuitive automated operation requires less training
    • Built in multi-level user management and data security
    • Event log & trouble shooting guide
    • Save on valuable lab space by eliminating need for PC
  • Coulox® Sensor
    • Short exam times reduces overall test time to increase throughput
    • No sensor calibration required
    • Longer sensor life than others on the market
    • More accurate and repeatable results vs. sensors that require calibration
    • Intrinsic sensor fully complies with ASTM D3985
  • Advanced Package Testing Features
    • Automatic quick purge to desired settings
    • Automatic high flow conditioning mode
    • Quick check verifies package is mounted properly before start of test
  • TruSeal®
    • Eliminate Individual Zero
    • Reduced testing time (increase throughput)
    • More repeatable results
    • Allows tool-less mounting of cartridges
  • Warranty
    • Full 100% parts and workmanship warranty for 12 months
    • Exclusive 4-year warranty on the Coulox sensor

Specifications

Brand

Test Ranges at 20.9% O₂

  • Model 10x: 0.0005 to 200 cc/(m² x day) | 0.00003 to 12.9 cc/(100 in² x day) | 0.0000025 to 1.0 cc/(pkg x day)
  • Model L: 0.005 to 200 cc/(m² x day) | 0.0003 to 12.9 cc/(100 in² x day) | 0.000025 to 1.0 cc/(pkg x day)
  • Model H: 0.05 to 200 cc/(m² x day) | 0.003 to 12.9 cc/(100 in² x day) | 0.00025 to 1.0 cc/(pkg x day)

Test Ranges Compensated to 100% O₂

  • Model 10x: 0.0025 to 1000 cc/(m² x day) | 0.00015 to 64.5 cc/(100 in² x day) | 0.0000125 to 5.0 cc/(pkg x day)
  • Model L: 0.025 to 1000 cc/(m² x day) | 0.0015 to 64.5 cc/(100 in² x day) | 0.000125 to 5.0 cc/(pkg x day)
  • Model H: 0.25 to 1000 cc/(m² x day) | 0.015 to 64.5 cc/(100 in² x day) | 0.00125 to 5.0 cc/(pkg x day)

Resolution (50 cm²)

  • Model 10x: 0.0002 cc/(m² x day)
  • Model L: 0.002 cc/(m² x day)
  • Model H: 0.02 cc/(m² x day)

Repeatability

  • Model 10x: 0.0005 or 1 % cc/(m² x day), whichever is Greater
  • Model L: 0.002 or 1 % cc/(m² x day), whichever is Greater
  • Model H: 0.02 or 1 % cc/(m² x day), whichever is Greater

Test Temperature Range

  • 10° C to 50° C ± 0.2° C

Controlled Humidity (RH) Testing Range

  • 5 to 90 % ± 4 %

Controlled RH Carrier Range

  • 0 to 90 % ± 4 %

Chamber Size

  • 25.5”W x 17”D x 12”H

Dimensions & Weight

  • 34.2” H x 33.0” W x 23.2” D (86.9 cm x 83.8 cm x 58.9 cm)
  • 225 lbs (102 kg)

Electrical Requirements

  • Voltage: 100-240 Vac 50/60 Hz
  • Maximum Power Draw: 500 VA

Laboratory Requirements

  • Temperature -  Operation: 22° C ± 2° C | Storage:  10° C to 30° C
  • Humidity - Operation: 10 % to 60 % RH (Non-Condensing) | Storage: 5 % to 85 % RH (Non-Condensing)

Gas Supply Requirements

  • Carrier Gas: Gas Composition - Nitrogen/Hydrogen Mix (98 %/2 %) | Supply Pressure, Nominal - 25 psi, (1.72 bar), (172 kPa)
  • Test Gas: Gas Composition - Dry Compressed Air (ISO 8753-1:2010[1:3:1]) | Supply Pressure Nominal - 85 psi, (5.86 bar), (586 kPa)

Connectivity

  • Remote Access and Control (requires Optional Perm-Net Light Software)
  • Standard Ethernet Port (100T)
  • Dual USB 2.0 Ports (for Connection of Keyboard, Mouse or Memory Devices)

Compliance Standards

  • This product is UL and CSA listed using the ETL mark from Intertek Group plc. and is certified to conform to CE
  • Conforms to the following internationally recognized safety standards: IEC 61010-1:2010 Third Edition | UL 61010-1:2012 Third Edition | CAN/CSA C22.2 No. 61010-1:2012 Third Edition
  • Conforms to the following internationally recognized EMC standards: EN 61326-1:2013 | EN 61000-3-2:2006, A1:2009, A2:2009 | EN 61000-3-3:2013
  • Conforms to EU Directive 2011/65/EU RoHS Compliance.

Cartridges & Options

  • 80 cm² Package Testing Cartridge
  • Large Vertical Tray Testing Cartridge
  • Flexible Pouch Testing Cartridge
  • 50 cm² Film Testing Cartridge
  • Package Adaptor Cartridge
  • Conditioning Rack Inside Chamber
  • Custom Engineered Cartridges

Accessories

  • Consumables: Cert Films 1-4 & Set, Single Use Package Mounting Foil Plates

Software

  • 21 CFR Part 11 User and Data Security
  • Remote Viewing Software from a PC - PermNet Lite

Service & Support Options

  • Basic Preventative Maintenance Plan
  • Plus Preventative Maintenance Plan
  • IQ/OQ Documentation & Validation

Test Standard Compliance

  • ASTM F2622
  • ISO CD 15105-2
  • JIS K-7126-B
  • DIN 53380-3
  • ASTM D3985
  • GB/T 19789-2005
  • ASTM F1307
  • ASTM F1927
  • GB/T 31354-2014

Test Methodology

  • Following ASTM D3985
  • Standard Test Method for Oxygen Gas Transmission Rate Through Plastic Film and Sheeting Using a Coulometric Sensor
  • The test specimen is mounted as a semi-barrier between two chambers at ambient atmospheric pressure. One chamber is slowly purged by a stream of nitrogen and the other chamber contains Oxygen. As Oxygen permeates through the film into the nitrogen carrier gas, it is transported to the coulometric detector where it produces an electrical current, the magnitude of which is proportional to the amount of oxygen flowing into the detector per unit of time.

  • Packaging Films
    • Monolayer
    • Multi-layer
    • Coated Films
    • Coated Paper/Paperboard
  • Packages
    • Common Food Packages
    • Medical Packages
    • Bottles/Closures
Instantly populate your store or catalog 
CREATE YOUR SITE
or book a demo with the Yodify Team
show more