Yodify Product Library
Instantly add the AW401 / AW402 Residual Chlorine Monitor and 50,000+ more product series to your store or catalog
Book Your Demo and See How
or create your store
AW401 / AW402 Residual Chlorine Monitor
Brand: ABB GroupResidual chlorine is one of the most important measurements for the effective monitoring of cooling, potable and industrial water treatment processes.
The AW401 residual chlorine monitor control and monitors residual chlorine levels accurately and affordably.
The AW401 design enables connection of up to 3 residual chlorine monitoring sensors to the system or enables pH, ORP and residual chlorine sensors to be combined, thus reducing the cost of each measurement considerably
Features- Total and free residual chlorine measurement
- add potassium iodide to reagent to convert free chlorine measurement to total chlorine
- Reagentless operation
- reduced operating costs with reagentless operation at a pH of 7.5 or less
- Multiple sensor input capability
- reduced installation costs for multiple point monitoring operations
- Self-cleaning sensor assembly
- prolongs sensor life and maintains accuracy
- Fast response time
- instant response to changes of residual chlorine, unlike batch / DPD methods
- Pressure-regulated sample flow
- no additional plumbing required to ensure optimum sample delivery rate and pressure
1 - 12 of 38 Part Numbers
AW4011001
- Transmitter Type - Transmitter
- Sensor Type Channel 1 - Chlorine Cell
- Sensor Type Channel 2 - No Second Input Channel
- Sensor Type Channel 3 - No Third Input Channel
- Transmitter Voltage - 115 Vac 50/60 Hz
AW4011002
- Transmitter Type - Transmitter
- Sensor Type Channel 1 - Chlorine Cell
- Sensor Type Channel 2 - No Second Input Channel
- Sensor Type Channel 3 - No Third Input Channel
- Transmitter Voltage - 230 Vac 50/60 Hz
AW4011011
- Transmitter Type - Transmitter
- Sensor Type Channel 1 - Chlorine Cell
- Sensor Type Channel 2 - No Second Input Channel
- Sensor Type Channel 3 - Chlorine Cell
- Transmitter Voltage - 115 Vac 50/60 Hz
AW4011012
- Transmitter Type - Transmitter
- Sensor Type Channel 1 - Chlorine Cell
- Sensor Type Channel 2 - No Second Input Channel
- Sensor Type Channel 3 - Chlorine Cell
- Transmitter Voltage - 230 Vac 50/60 Hz
AW4011061
- Transmitter Type - Transmitter
- Sensor Type Channel 1 - Chlorine Cell
- Sensor Type Channel 2 - No Second Input Channel
- Sensor Type Channel 3 - pH
- Transmitter Voltage - 115 Vac 50/60 Hz
AW4011062
- Transmitter Type - Transmitter
- Sensor Type Channel 1 - Chlorine Cell
- Sensor Type Channel 2 - No Second Input Channel
- Sensor Type Channel 3 - pH
- Transmitter Voltage - 230 Vac 50/60 Hz
AW4011071
- Transmitter Type - Transmitter
- Sensor Type Channel 1 - Chlorine Cell
- Sensor Type Channel 2 - No Second Input Channel
- Sensor Type Channel 3 - ORP
- Transmitter Voltage - 115 Vac 50/60 Hz
AW4011072
- Transmitter Type - Transmitter
- Sensor Type Channel 1 - Chlorine Cell
- Sensor Type Channel 2 - No Second Input Channel
- Sensor Type Channel 3 - ORP
- Transmitter Voltage - 230 Vac 50/60 Hz
AW4011101
- Transmitter Type - Transmitter
- Sensor Type Channel 1 - Chlorine Cell
- Sensor Type Channel 2 - Chlorine Cell
- Sensor Type Channel 3 - No Third Input Channel
- Transmitter Voltage - 115 Vac 50/60 Hz
AW4011102
- Transmitter Type - Transmitter
- Sensor Type Channel 1 - Chlorine Cell
- Sensor Type Channel 2 - Chlorine Cell
- Sensor Type Channel 3 - No Third Input Channel
- Transmitter Voltage - 230 Vac 50/60 Hz
AW4011111
- Transmitter Type - Transmitter
- Sensor Type Channel 1 - Chlorine Cell
- Sensor Type Channel 2 - Chlorine Cell
- Sensor Type Channel 3 - Chlorine Cell
- Transmitter Voltage - 115 Vac 50/60 Hz
AW4011112
- Transmitter Type - Transmitter
- Sensor Type Channel 1 - Chlorine Cell
- Sensor Type Channel 2 - Chlorine Cell
- Sensor Type Channel 3 - Chlorine Cell
- Transmitter Voltage - 230 Vac 50/60 Hz
1 - 12 of 38 Part Numbers
Specifications
Brand
Measurement Range
- Chlorine, Chlorine Dioxide, Ozone: 0 to 20 ppm (mg/l)
Accuracy
- Buffered: 2 % or ± 10 ppb, whichever is greater at < PH10
- Unbuffered: 2 % or ± 0.01 10 ppb, whichever is greater at pH < 7.5
Sensitivity
- 0.001 ppm
Minimum Detection Limit
- 0.005 ppm
Drift
- Span Drift: -5 % over 30 days Max.
- Zero Drift: ± 1 % over 30 days Max.
Response Time
- 90 % in less than 90 seconds
Operating Temperature
- -10° to 50° C (14° to 122° F)
Humidity
- 50 % Relative Humidity at 40° C (104° F) with linear decrease
- 80 % Relative Humidity at 31° C (88° F)
Sample Temperature
- Compensated between 2° and 50° C (36° and 122° F)
Sample Pressure
- Outlet: Pressureless
- Inlet: 0.2 to 4.0 bar (3 to 60 psi)
Sample Flow
- Continuous, 60 to 75 L/hr
Sample PH Value
- 4 to 7.5
Materials of Construction
- Tubing: Polyethylene or flexible PVC
- Differential Pressure regulator: PVC
- Electrode Chamber: Plexiglas
- Electrodes: Gold / Copper
Environment Protection
- IP64
- IP65
Certifications & Approvals
- CE
Power Supply
- 115 Vac, ± 10 %, 50/60 Hz
- 230 Vac, ± 10 %, 50/60 Hz
Power Consumption
- 20 VA Max.
- Drinking Water
- Cooling Water for Power Stations & Industrial Facilities
- Fruit & Vegetable Disinfection Baths
- Tertiary Treated Waste Water
- Swimming Pools and Spas