Yodify Product Library
Add the Supply Module Series 9193 to your store or catalog
Book Your Demo and See How
or create your store
Supply Module Series 9193
Brand: R. STAHL AGThe 9193 series supply module supplies the pac bus with auxiliary power and reads any line fault messages or auxiliary power failures for all of the ISpac devices installed on the pac bus.
The supply current of up to 4 A is sufficient for approximately 30-50 modules.
Power can be supplied using a single or redundant system.
The device is provided with an interchangeable fuse.
Features- Redundant supply for increased availability
- DIP switch makes adjusting operating statuses easy
- Can be used for ISpac Series 91xx und 92xx
1 - 2 of 2 Part Numbers

160717
Redundant supply for increased availability
DIP switch makes adjusting operating statuses easy
Can be used for ISpac Series 91xx und 92xx
Ambient Conditions
- Ambient temperature - -20 °C ... +70 °C (Single device) -20 °C ... +60 °C (Group assembly)
- Ambient temperature max. - +70 °C
- Ambient temperature max. note - Single device
- Ambient temperature max. note 2 - Group assembly
- Ambient temperature max.2 - +60 °C
- Ambient temperature min. - -20 °C
- Ambient temperature min. 2 - -20 °C
- Ambient temperature min. note - Single device
- Ambient temperature min. note 2 - Group assembly
- Electromagnetic compatibility - Tested to the following standards and regulations: EN 61326-1 Use in industrial environment; NAMUR NE 21
- Relative humidity max. - 95%
- Storage temperature - -40 °C ... +80 °C
- Storage temperature max. - +80 °C
- Storage temperature min. - -40 °C
- Use at the height of - 2000 m
Auxiliary power
- Auxiliary power - 24 V DC
- Auxiliary power voltage range - 18 … 31,2 V
- Nominal current - 4.00 A
- Nominal voltage - 24 V DC
- Polarity reversal protection - yes
- Power dissipation max. - 2.50 W
- Redundant supply - yes, decoupled with diodes
Electrical Data
- Auxiliary power failure PF - Contact (30 V / 100 mA)
- Error messaging device - Line fault
- Error messaging device 2 - Auxiliary power failure
- Fuse - 5 x 20 mm; 2 x T 4.0 A; exchangeable for prim. and red. supply
- Line fault LF - Contact (30 V / 100 mA)
- Number of channels - 1
- Redundancy - Yes, diode-decoupled
- Supply - 24 V/4 A, primary + redundant
Explosion Protection
- Application range (zones) - 2, 22
- ATEX gas certificate - BVS 03 ATEX E 213 X
- Certificate EAC - TS RU S-DE.GB04.B.00353
- Certificates - ATEX (BVS), Brazil (ULB), Canada (FM), EAC (STV), IECEx (BVS), India (PESO), USA (FM)
- Gas explosion protection ATEX - II 3 G Ex nA nC IIC T4 Gc
- Gas explosion protection EAC - 2 Ex nA nC IIC T4 Gc X
- Gas explosion protection IECEx - Ex nA nC IIC T4 Gc
- IECEX gas certificate - IECEx BVS 10.0042 X
- Installation in Division NEC 500 - (Class I, II, III) 2
- Ship approval - CCS, DNVGL
General
- Functional Description - The 9193 series supply module supplies the pac bus with auxiliary power and reads any line fault messages or auxiliary power failures for all of the ISpac devices installed on the pac bus. The supply current of up to 4 A is sufficient for approximately 30-50 modules. Power can be supplied using a single or redundant system. The device is provided with an interchangeable fuse.
- Highlights - Redundant supply for increased availability DIP switch makes adjusting operating statuses easy Can be used for ISpac Series 91xx und 92xx
- Product Description - Supply Module ISpac
- Product Type - 9193/20-11-11s
- Title Product Variant Technical Data - 9193/20-11-11s supply module
- WebCode - 9193A
Input
- Message of line fault and Auxilliary power failure - - Contact (30 V / 100 mA) closed to ground in case of fault - pac-Bus, floating contact (30 V / 100 mA)
Mechanical Data
- Connection cross-section - 0.2-2.5 mm² flexible 0.25-2.5 mm² flexible core end sleeve 0.2-2.5 mm² rigid
- Degree of protection (IP) - IP30
- Enclosure material - Polyamide
- Fire resistance (UL 94) - V0
- Grid dimension - 17.60 mm
- Terminal degree of protection (IP) - IP20
- Weight - 0.195 kg
Mounting / Installation
- Connection type - Screw terminal
- Mounting position - vertical horizontal
- Mounting type - NS35/15, NS35/7.5 DIN rail
Output
- LFD relay - Yes
- Output - 24 V/max. 4 A, supply via pac-Bus

160718
Redundant supply for increased availability
DIP switch makes adjusting operating statuses easy
Can be used for ISpac Series 91xx und 92xx
Ambient Conditions
- Ambient temperature - -20 °C ... +70 °C (Single device) -20 °C ... +60 °C (Group assembly)
- Ambient temperature max. - +70 °C
- Ambient temperature max. note - Single device
- Ambient temperature max. note 2 - Group assembly
- Ambient temperature max.2 - +60 °C
- Ambient temperature min. - -20 °C
- Ambient temperature min. 2 - -20 °C
- Ambient temperature min. note - Single device
- Ambient temperature min. note 2 - Group assembly
- Electromagnetic compatibility - Tested to the following standards and regulations: EN 61326-1 Use in industrial environment; NAMUR NE 21
- Relative humidity max. - 95%
- Storage temperature - -40 °C ... +80 °C
- Storage temperature max. - +80 °C
- Storage temperature min. - -40 °C
- Use at the height of - 2000 m
Auxiliary power
- Auxiliary power - 24 V DC
- Auxiliary power voltage range - 18 … 31,2 V
- Nominal current - 4.00 A
- Nominal voltage - 24 V DC
- Polarity reversal protection - yes
- Power dissipation max. - 2.50 W
- Redundant supply - yes, decoupled with diodes
Electrical Data
- Auxiliary power failure PF - Contact (30 V / 100 mA)
- Error messaging device - Line fault
- Error messaging device 2 - Auxiliary power failure
- Fuse - 5 x 20 mm; 2 x T 4.0 A; exchangeable for prim. and red. supply
- Line fault LF - Contact (30 V / 100 mA)
- Number of channels - 1
- Redundancy - Yes, diode-decoupled
- Supply - 24 V/4 A, primary + redundant
Explosion Protection
- Application range (zones) - 2, 22
- ATEX gas certificate - BVS 03 ATEX E 213 X
- Certificate EAC - TS RU S-DE.GB04.B.00353
- Certificates - ATEX (BVS), Brazil (ULB), Canada (FM), EAC (STV), IECEx (BVS), India (PESO), USA (FM)
- Gas explosion protection ATEX - II 3 G Ex nA nC IIC T4 Gc
- Gas explosion protection EAC - 2 Ex nA nC IIC T4 Gc X
- Gas explosion protection IECEx - Ex nA nC IIC T4 Gc
- IECEX gas certificate - IECEx BVS 10.0042 X
- Installation in Division NEC 500 - (Class I, II, III) 2
- Ship approval - CCS, DNVGL
General
- Functional Description - The 9193 series supply module supplies the pac bus with auxiliary power and reads any line fault messages or auxiliary power failures for all of the ISpac devices installed on the pac bus. The supply current of up to 4 A is sufficient for approximately 30-50 modules. Power can be supplied using a single or redundant system. The device is provided with an interchangeable fuse.
- Highlights - Redundant supply for increased availability DIP switch makes adjusting operating statuses easy Can be used for ISpac Series 91xx und 92xx
- Product Description - Supply Module ISpac
- Product Type - 9193/20-11-11k
- Title Product Variant Technical Data - 9193/20-11-11k supply module
- WebCode - 9193A
Input
- Message of line fault and Auxilliary power failure - - Contact (30 V / 100 mA) closed to ground in case of fault - pac-Bus, floating contact (30 V / 100 mA)
Mechanical Data
- Connection cross-section - 0.2-2.5 mm² flexible 0.2-2.5 mm² rigid 0.25-2.5 mm² flexible core end sleeve
- Degree of protection (IP) - IP30
- Enclosure material - Polyamide
- Fire resistance (UL 94) - V0
- Grid dimension - 17.60 mm
- Terminal degree of protection (IP) - IP20
- Weight - 0.195 kg
Mounting / Installation
- Connection type - Spring clamp terminal
- Mounting position - vertical horizontal
- Mounting type - NS35/15, NS35/7.5 DIN rail
Output
- LFD relay - Yes
- Output - 24 V/max. 4 A, supply via pac-Bus
1 - 2 of 2 Part Numbers