Brand: Holcim ElevateSuitable for a variety of low-slope commercial roofing applications, Elevate UltraPly™ TPO, formerly Elevate UltraPly™ TPO, roofing membrane is a sustainable roofing solution for a wide range of building types.
UltraPly TPO membrane also offers design options with panels available in reflective white, tan or gray, which can help reduce a building’s cooling requirements.
White and tan UltraPly TPO membranes meet the California Energy Efficiency Standards for Residential and Nonresidential Buildings (Title 24).
These standards define cool roofs in California to have a minimum three-year aged reflectance of 0.55 and a minimum thermal emittance of 0.75 for low-sloped nonresidential buildings.
White and tan UltraPly TPO membranes are listed with the Cool Roof Rating Council (CRRC).
Features- Ozone and Chemical resistant
- Flexible
- Hot-air welded membrane
- Available in 5′, 8′, 10′ and 12′ widths
- Available in thicknesses of .045″, .060″ and .080″
- Puncture resistant
- Reduces roof’s surface temperature
- Can add LEED points
- Elevate UltraPly's proven formulation has been the same for over 20 years, giving contractors, specifiers, and building owners long-term confidence in Elevate UltraPly
Specifications
Brand
Overall Thickness
- D 751
- 0.039” (1 mm)
- 0.045” (1.14 mm) ± 10 %
- 0.060” (1.52 mm) ± 10 %
Coating Over Scrim
- D 7635
- 0.015” (0.38 mm)
- 0.017” (0.43 mm)
- 0.021” (0.53 mm)
Breaking Strength
- D 751, Grab Method
- 220 lbf (979 N)
- 340 lbf (1,512 N)
- 390 lbf (1,735 N)
Elongation of Reinforcement Break
- D 751, Grab Method
- 15%
- 25%
Tearing Strength
- D 751
- 55 lbf (245 N)
- 120 lbf (534 N)
Brittleness Point
- D 2137
- -40° F (-40° C)
- Pass
Ozone Resistance, No Cracks
- D 1149
- Pass (No Cracks)
- Pass
Elongation at Break
- D 751, Grab Method
- 90 % Min.
- > 90 %
Tearing Strength
- D 751
- 60 % Min.
- > 60 %
Weight of Change
- ± 1 % Max.
- < 1 %
Linear Dimension Change
- D 1204, 6 h at 158° F (70° C)
- ± 1 % Max.
- < 1 %
Water Absorption
- D 471
- ± 3 % Max.
- < 3 %
Weather Resistance
- G 155
- 10,800 kJ/m² Min.
- > 60,000 kJ/m²
Puncture Resistance
- FTM 101C, Method 2031
- 265 (1,180)
- 300 (1,300)
Dynamic Puncture Resistance MD
- D 5635
- Pass (20 J)
- Pass (40 J)
Dynamic Puncture Resistance CD
- D 5635
- Pass (35 J)
- Pass (50 J)
Static Puncture Resistance
- D 5602
- Pass (25 kg)
Air Permeance (Material)
- E 2178
- < 0.004 ft³/ft² (0.02 L/(s*m²)