Yodify Product Library
Instantly add the Fluke T6-1000 Electrical Tester and 50,000+ more product series to your store or catalog  
Book Your Demo and See How
or create your store

Fluke T6-1000 Electrical Tester

Brand: Fluke Corporation

The Fluke T6-1000 Electrical Tester with FieldSense™ technology lets you quickly, safely take True rms voltage and current measurements without test leads.

Unlike other fork testers that merely detect voltage, the T6-1000 makes actual measurements, without contacting a live, metallic conductor. 

Just slide the 17.8 mm open fork, the widest in the industry, over a conductor and read simultaneous voltage and current values. Or simultaneous frequency and current values. 

The open fork works with wires up to AWG 4/0 (120 mm2). Or, you can use the attached test leads to measure voltage DC to 1000 V.
Features
  • Measure voltage to 1000 V AC without test leads
  • Simultaneously measure voltage and current
  • 17.8 mm open fork is widest in the industry
  • Measure up to 200 A on 4/0 wires (120 mm2)

1 - 2 of 2 Part Numbers
Fluke T6-1000 Electrical Tester
Fluke T6-1000 Electrical Tester
Fluke T6-1000 Electrical Tester
IBT6K
IBT6K
T6 Electrical Tester + Insulated Hand Tools Starter Kit
Includes:
  • Fluke T6-1000 Electrical Tester
  • ISLS3 Insulated Slotted Screwdriver 3/32, 3"
  • ISLS5 Insulated Slotted Screwdriver 5/32, 4"
  • ISLS8 Insulated Slotted Screwdriver 1/4, 5"
  • IPHS1 Insulated Phillips Screwdriver #1, 3"
  • IPHS2 Insulated Phillips Screwdriver #2, 4"
  • INLP8 Insulated Long Nose /w Side Cutter and Gripping Zones
  • INDC8 Insulated Heavy Duty High Leverage Diagonal Cutter
  • INCP8 Insulated Heavy Duty Linesman Combination Plier
  • RUP8 Roll up pouch
1 - 2 of 2 Part Numbers

Specifications

FieldSense AC Voltage True-rms

  • Range: 1000 V
  • Resolution: 1 V
  • Accuracy: ± (3 % + 3 counts)

FieldSense AC Current True-rms

  • Range: 200.0 A
  • Resolution: 0.1 A
  • Accuracy: ± (3 % + 3 counts)

FieldSense Frequency

  • Range: 45 Hz - 66 Hz
  • Resolution: 1 Hz
  • Accuracy: ± (1 % + 2 counts)

Volts ac True-rms

  • Range: 1000 V
  • Resolution: 1 V
  • aCCURACY: ± (1.5 % + 2 counts)

Volts dc

  • rANGE: 1000 V
  • Resolution: 1 V
  • Accuracy: ± (1 % + 2 counts)

Operating Temperature

  • -10° C to +50° C
  • 14° F to 122° F

Relative Humidity

  • 0 % to 90 %, 5° C to 30° C (41° F to 86° F)
  • 0 % to 75 %, 30° C to 40° C (86° F to 104° F)
  • 0 % to 45 %, 40° C to 50° C (104° F to 122° F)

Safety

  • IEC/EN 61010-1: Pollution Degree 2

Electromagnetic Environment

  • IEC/EN 61326-1: Portable