Brand: Kane International Limited

Features
  • Measures Temperature, Pressure, O₂ and CO as standard
  • Stores 150 sets of test results
  • Output to IR Printer (optional)
OPTIONS
  • (CO and any two other sensors)
  • High range CO sensor
  • Low range NO sensor
  • High range NO sensor
  • NO₂ sensor
  • SO₂ sensor
  • Wireless upgrade (2.1)
  • Teflon Hose

Specifications

Ambient Operating Range

  • -5° to +50° C / 10 % to 90 % RH, Non-Condensing

Battery Life

  • > 8 Hours from Full Charge

Gas Measurement Accuracy

  • Carbon Dioxide: ± 0.3 % of Reading
  • Carbon Monoxide (H₂ Compensated), Carbon Monoxide: ± 20 ppm 400 ppm
  • Carbon Monoxide: ± 10 % > 5000 ppm
  • Carbon Monoxide: ± 5 % 100 ppm
  • Oxygen, Excess Air: ± 0.2 %
  • Poison Index: ± 0.01
  • Pressure: ± 0.5 % of Full Scale
  • Sulphur Dioxide (Optional): +5 % > 100 ppm
  • Temp (Nett): ± 2° C ± 0.3 % of Reading

Gas Measurement Range

  • Carbon Dioxide, Losses, Efficiency: 0 - 99.9 %
  • Carbon Monoxide (H₂ Compensated): 0 - 4000 ppm
  • Carbon Monoxide: 0 - 100000 ppm
  • CO / CO₂ Ratio: 0 - 0.9999
  • Excess Air: 0 - 2885.0 %
  • Nitric Oxide (Low Range): 0 - 100 ppm
  • Nitric Oxide & Sulphur Dioxide (Optional): 0 - 5000 ppm
  • Nitrogen Dioxide (Optional): 100 ppm
  • Oxygen: 0 - 25 %
  • Poison Index: 0 - 99.99
  • Pressure: 150 Mbar
  • Temp (Nett): 0° C - 1200° C / 32° to 2200° F

Gas Measurement Resolution

  • Carbon Monoxide (H₂ Compensated), Carbon Monoxide, Nitric Oxide (Low Range & Optional), Nitrogen Dioxide & Sulphur Dioxide (Optional): 1 ppm
  • CO / CO₂ Ratio: 0.0001
  • Oxygen, Carbon Dioxide, Losses, Efficiency, Excess Air: 0.1 %
  • Poison Index: 0.01 %
  • Pressure: 0.1 Mbar
  • Temperature (Nett): 1.0° C/F

Power Supply (Battery Charger)

  • Input: 110 VAC/220 VAC Nominal
  • Output: 12 VAC Off Load

Pre-Programmed Fuels

  • Natural Gas, Town Gas, Gascor, Light Oil, Heavy Oil, Propane, Butane, Anthracite, Coke, Coal, Kinsale Gas

Sensor, Probe

  • L240 mm x Dia8 mm with 285 mm Long Stainless Steel Shaft, Typical K Thermocouple & 1.5 M Long Neoprene Hose

Temperature Measurement Accuracy

  • Flue Temperature: ± 2.0° C ± 0.3 % of Reading
  • Inlet Temperature: ± 1° C ± 0.3 % of Reading

Temperature Measurement Range

  • Flue Temperature: 0° to 1200° C / 32° to 2200° F with Suitable Probe
  • Inlet Temperature: 0° to 50° C / 32° to 122° F

Temperature Measurement Resolution

  • Flue Temperature, Inlet Temperature: 0.1° C/F