Yodify Product Library
Instantly add the Installation Switch Series 8040/11-V30 and 50,000+ more product series to your store or catalog
Book Your Demo and See How
or create your store
Installation Switch Series 8040/11-V30
Brand: R. STAHL AGThe installation switches Series 8040/11-V30 are used for lighting installations. The switch position is shown unambiguously by the 90° position.
This is especially convenient if lights and switch are in different rooms. The fluorescent turning handle can be useful in the case of a power failure.
Features- Available as 2 pole OFF switch or changeover switch
- Enclosure made of optical fibre reinforced polyester resin
- Clear position indicator 0/1 or ON/OFF
1 - 4 of 4 Part Numbers
245656
Available as 2 pole OFF switch or changeover switch
Enclosure made of optical fibre reinforced polyester resin
Clear position indicator 0/1 or ON/OFF
Ambient Conditions
- Ambient temperature - -60 °C ... +60 °C
- Ambient temperature max. - +60 °C
- Ambient temperature min. - -60 °C
Components
- Screw connections - 1 x M25 Ø 7 to 17 mm
- Stopping plug - 2 x M25 x 1.5
Electrical Data
- No. of poles - 2
- Rated operational current - 16.000 A
- Rated operational voltage AC - 690.00 V
- Rated operational voltage DC - 220.00 V
Explosion Protection
- Application range (zones) - 1, 2, 21, 22
- ATEX dust certificate - PTB 01 ATEX 1105
- ATEX gas certificate - PTB 01 ATEX 1105
- Certificates - ATEX (PTB), Brazil (ULB), China (CQST), EAC (LPE), IECEx (PTB), India (PESO), Korea (KGS), Taiwan (ITRI)
- Dust explosion protection ATEX - II 2 D Ex tb IIIC T80 °C Db
- Dust explosion protection IECEx - Ex tb IIIC T80 °C Db
- Gas explosion protection ATEX - II 2 G Ex db eb IIC T6 Gb
- Gas explosion protection IECEx - Ex db eb IIC T6 Gb
- IECEX dust certificate - IECEx PTB 06.0025
- IECEX gas certificate - IECEx PTB 06.0025
- Ship approval - GL
General
- Functional Description - The installation switches Series 8040/11-V30 are used for lighting installations. The switch position is shown unambiguously by the 90° position. This is especially convenient if lights and switch are in different rooms. The fluorescent turning handle can be useful in the case of a power failure.
- Highlights - Available as 2 pole OFF switch or changeover switch Enclosure made of optical fibre reinforced polyester resin Clear position indicator 0/1 or ON/OFF
- Product Description - Installation switch OFF switch
- Product Type - 8040/11-V30-033-S
- Title Product Variant Technical Data - 8040/11-V30-033-S 2-pole installation sw
- WebCode - 8040F
Mechanical Data
- Connection terminals finely-stranded max. - 2.50 mm²
- Connection terminals min. - 1.50 mm²
- Connection terminals solid max. - 4.00 mm²
- Contact material - silver-nickel
- Degree of protection (IP) - IP66
- Degree of protection note - according to IEC/EN 60529
- Enclosure material - Polyester, Glass fibre reinforced
- Sealing material - Silicone
- Service life, min. - 100,000 operating cycles
- Version - OFF switch
- Weight - 0.600 kg
Mounting / Installation
- Tightening torque - 1.80 N/m
245657
Available as 2 pole OFF switch or changeover switch
Enclosure made of optical fibre reinforced polyester resin
Clear position indicator 0/1 or ON/OFF
Ambient Conditions
- Ambient temperature - -20 °C ... +60 °C
- Ambient temperature max. - +60 °C
- Ambient temperature min. - -20 °C
Components
- Screw connections - 1 x M25 Ø 7 to 17 mm
- Stopping plug - 2 x M25 x 1.5
Electrical Data
- No. of poles - 2
- Rated operational current - 16.000 A
- Rated operational voltage AC - 690.00 V
- Rated operational voltage DC - 220.00 V
Explosion Protection
- Application range (zones) - 1, 2, 21, 22
- ATEX dust certificate - PTB 01 ATEX 1105
- ATEX gas certificate - PTB 01 ATEX 1105
- Certificates - ATEX (PTB), Brazil (ULB), China (CQST), EAC (LPE), IECEx (PTB), India (PESO), Korea (KGS), Taiwan (ITRI)
- Dust explosion protection ATEX - II 2 D Ex tb IIIC T80 °C Db
- Dust explosion protection IECEx - Ex tb IIIC T80 °C Db
- Gas explosion protection ATEX - II 2 G Ex db eb IIC T6 Gb
- Gas explosion protection IECEx - Ex db eb IIC T6 Gb
- IECEX dust certificate - IECEx PTB 06.0025
- IECEX gas certificate - IECEx PTB 06.0025
- Ship approval - GL
General
- Functional Description - The installation switches Series 8040/11-V30 are used for lighting installations. The switch position is shown unambiguously by the 90° position. This is especially convenient if lights and switch are in different rooms. The fluorescent turning handle can be useful in the case of a power failure.
- Highlights - Available as 2 pole OFF switch or changeover switch Enclosure made of optical fibre reinforced polyester resin Clear position indicator 0/1 or ON/OFF
- Product Description - Installation switch Two-way circuit
- Product Type - 8040/11-V30-035-B
- Title Product Variant Technical Data - 8040/11-V30-035-B Install. change o. sw.
- WebCode - 8040F
Mechanical Data
- Connection terminals finely-stranded max. - 2.50 mm²
- Connection terminals min. - 1.50 mm²
- Connection terminals solid max. - 4.00 mm²
- Contact material - silver-nickel
- Degree of protection (IP) - IP66
- Degree of protection note - according to IEC/EN 60529
- Enclosure material - Polyester, Glass fibre reinforced
- Sealing material - NBR
- Service life, min. - 100,000 operating cycles
- Version - Two-way circuit
- Weight - 0.615 kg
Mounting / Installation
- Tightening torque - 1.80 N/m
245658
Available as 2 pole OFF switch or changeover switch
Enclosure made of optical fibre reinforced polyester resin
Clear position indicator 0/1 or ON/OFF
Ambient Conditions
- Ambient temperature - -60 °C ... +60 °C
- Ambient temperature max. - +60 °C
- Ambient temperature min. - -60 °C
Components
- Screw connections - 1 x M25 Ø 7 to 17 mm
- Stopping plug - 2 x M25 x 1.5
Electrical Data
- No. of poles - 2
- Rated operational current - 16.000 A
- Rated operational voltage AC - 690.00 V
- Rated operational voltage DC - 220.00 V
Explosion Protection
- Application range (zones) - 1, 2, 21, 22
- ATEX dust certificate - PTB 01 ATEX 1105
- ATEX gas certificate - PTB 01 ATEX 1105
- Certificates - ATEX (PTB), Brazil (ULB), China (CQST), EAC (LPE), IECEx (PTB), India (PESO), Korea (KGS), Taiwan (ITRI)
- Dust explosion protection ATEX - II 2 D Ex tb IIIC T80 °C Db
- Dust explosion protection IECEx - Ex tb IIIC T80 °C Db
- Gas explosion protection ATEX - II 2 G Ex db eb IIC T6 Gb
- Gas explosion protection IECEx - Ex db eb IIC T6 Gb
- IECEX dust certificate - IECEx PTB 06.0025
- IECEX gas certificate - IECEx PTB 06.0025
- Ship approval - GL
General
- Functional Description - The installation switches Series 8040/11-V30 are used for lighting installations. The switch position is shown unambiguously by the 90° position. This is especially convenient if lights and switch are in different rooms. The fluorescent turning handle can be useful in the case of a power failure.
- Highlights - Available as 2 pole OFF switch or changeover switch Enclosure made of optical fibre reinforced polyester resin Clear position indicator 0/1 or ON/OFF
- Product Description - Installation switch Two-way circuit
- Product Type - 8040/11-V30-035-S
- Title Product Variant Technical Data - 8040/11-V30-035-S Install. change o. sw.
- WebCode - 8040F
Mechanical Data
- Connection terminals finely-stranded max. - 2.50 mm²
- Connection terminals min. - 1.50 mm²
- Connection terminals solid max. - 4.00 mm²
- Contact material - silver-nickel
- Degree of protection (IP) - IP66
- Degree of protection note - according to IEC/EN 60529
- Enclosure material - Polyester, Glass fibre reinforced
- Sealing material - Silicone
- Service life, min. - 100,000 operating cycles
- Version - Two-way circuit
- Weight - 0.615 kg
Mounting / Installation
- Tightening torque - 1.80 N/m
1 - 4 of 4 Part Numbers