Yodify Product Library
Instantly add the Model F2301/F23C1 Tension/Compression Force Transducer and 50,000+ more product series to your store or catalog  
Book Your Demo and See How
or create your store

Model F2301/F23C1 Tension/Compression Force Transducer

Brand: Tecsis

These force transducers are made of high-strength, corrosion resistant stainless steel 1.4542, which is particularly suitable for their application areas. 

The standard active current and voltage outputs are available as output signals (4-20 mA/0-10 V). 

Redundant output signals are possible.
Features
  • Thin film implants (instead of conventional bonded foil strain gauges)
  • Corrosion free stainless steel
  • Integrated amplifier
  • Small temperature drift
  • High long term stability
  • High shock and vibration resistance
  • For dynamic or static measurements
  • Good repeatability
  • Easy to install

1 - 3 of 3 Part Numbers
F2301
F2301
  • Approval / Protection - Standard
F23C1 ATEX/IECEX
F23C1 ATEX/IECEX
  • Approval / Protection - ATEX/IECEX for II 2G Ex ib IIC T4/T3
F23C1 SIL-3
F23C1 SIL-3
  • Approval / Protection - SIL-3 Approval with 2-Channel PC Control
1 - 3 of 3 Part Numbers

Specifications

Brand

Accuracy

  • ± 0.1 % of Full Scale
  • 0.2%

Approvals & Certifications

  • ATEX
  • CSA
  • EMC According to Directive EN 61326
  • FM
  • IEC Ex
  • TÜV-Sud- No. Z-IS-ATA3-MAN 6000219499 According to EN 62061: 2005
  • UL

Approvals & Certifications

  • EN
  • ISO 9001: 2015 Certified
  • SIL 3 Certification

Channels

  • 2

Consumption

  • Power Consumption Relay: Approximately 100 mW

Electrical Connectors

  • Circular Connector 4-Pin M12 x 1 - F2301

Electrical Protection

  • Overvoltage
  • Reverse Polarity Voltage
  • Short Circuit Protected

Environmental Protection

  • IP67 (According to EN 60529 / IEC 529)

Hysteresis

  • ≤ ± 0.1 % of Full Scale Cn

Insulation Resistance

  • > 5 GigaOhms / 50 V

Load

  • Maximum

Load Limit

  • 150 % Fnom
  • Breaking Load: > 300 % Fnom

Materials of Construction

  • Material Counter Nut: Nickel-Plated Steel - F2301

Measuring Error

  • Combined Error: ≤ ± 0.2 % of Full Scale

Measuring Range

  • Tension & Compression Forces from 1 to 100 KN

Output

  • Analog Output: 0-7 V, 3-Wire - F23C1 SIL 3
  • Analog Output: 4-16 mA, 2-Wire - F23C1 SIL 3
  • Analog Output: 4-20 mA, 2-Wire - F2301
  • Maximum
  • Voltage Output: Approximately 8 mA - F2301, F23C1 SIL 3

Power Requirement

  • 10-30 Vdc for Current Output - F2301
  • 14-30 Vdc for Voltage Output - F2301

Power Supply

  • Relay Power Supply: 24 V, Max.

Response Time

  • ≤ 1 millisecond (within 10 % to 90 %) - F2301
  • ≤ 5 milliseconds (within 10 % to 90 %) - F23C1 SIL 3

Service Temperature

  • -40° to 80° C (-40° to 176° F)

Span & Zero Effect

  • ≤ ± 0.2 % of Full Scale/10K

Storage Temperature

  • -40° to 85° C (-40° to 185° F)

Temperature Effect

  • Span & Zero: ≤ ± 0.2 % of Full Scale/10K

Temperature Range

  • Nominal -20° to 80° C (-4° to 176° F)

Vibration

  • 20 G, 100h, (50 to 150 Hz) According to DIN EN 60068-2-6

  • Chemical & Petrochemical
  • Cranes
  • Dedusting & Filtration Units
  • Hoists
  • Mechanical Engineering & Machinery
  • Mining
  • OEM Applications
  • Process Automation
  • Screw Down Forces in Machinery