Brand: OldhamThe CPS Car Park System provides accurate and reliable monitoring for the highest level of protection in parking facilities and tunnels.
The system was designed to comply with the high safety standards enforced in such European countries as Germany, the Netherlands and Belgium.
Continuous monitoring significantly reduces your operating costs by optimizing the efficiency of ventilation systems and servo controls. Such efficiencies can produce energy savings of up to 40% when used with specific equipment.
Features- Up to 256 points per system
- Up to 1,000 times faster than a pump system
- Parking facility electricity savings of up to 40%
Specifications
Brand
Ambient Temperature Range
- -10° to 40° C (14° to 104° F)
Approvals & Certifications
- ANSI/UL 61010-1-2005 CAN/CSA C22.2 No. 61010-1
- CE
- EMC EN 50270
- ETL
- LVD Directive 2014/35/EU, 61010-1
- TÜV
Cable Entry
- 2 M16 Cable Glands (4 to 8 mm Diameter Power Supply/Local Relays) - CPS 10 Sensor Module
- 5 M20 Cable Glands (Diameter: 5 to 12 mm for Power Supply & Local Relays) - CPS Central Detection Controller
- 9 Grommets (Diameter: 5 to 7 mm) - CPS Central Detection Controller
- PG9 - CPS Central Detection Controller
Cable Type
- 2 Shielded Twisted Pairs RS-485 Cable
Calibration
- Automatic Calibration
- Non-Intrusive
Communication
- Digital Output: RS-232 - Alarm
- Digital Output: USB Protocol Priority - Alarm
- Modbus RS-485 - Measuring Line (Digital Module Network [1 to 32 Addresses Selected with Mini Switches]), Alarm (Digital Output)
Consumption
- 130 mA (256 mA - Max.
- 140 mA + 12 mA Per Measurement Line (240 mA - Max.
- 2.5 mA for the Toxic Sensor (4-20 mA - Max.
- 3.2 mA (5.5 mA - Max.
- 3.4 mA (5.7 mA - Max.
- 50 mA Explo (90.7 mA - Max.
Display
- Backlit LCD Display Screen (2 Lines of 32 Characters Each - 1 Line of Pictograms) 3 Operation Status LEDs: OK, Fault, Alarms
Electrical Connectors
- Screwing Terminals (Cable: 1.5 mm²)
Electrical Contacts
- RCT-Typical
Electrical Rating
- 2 A at 250 V - CPS RM4 or RM8 Relay Module
- 2 A at 250 Vac-30 Vcc (Resistive Charge) - Alarm
Environmental Protection
- IP 31
- IP54
Humidity
- 5 to 95 % - Non-Condensing
Indication
- Local Buzzer: Audible Alarm - Measuring Line
- Local Buzzer: Fault Signals - Measuring Line
- Status Indication after Calibration: Red/Green Electroluminescent Diode - CPS 10 Sensor Module
Isolation
- 1500 V between the Power Supply & the Digital Network
Measuring Range
- Carbon Monoxide: 0 to 300 ppm in 1 ppm Increments
- Methane, Liquefied Petroleum Gas, Hydrogen: 0 to 100 % Lower Explosive Limit (LEL) in 1 % Increments
- Nitric Oxide: 0 to 100 ppm in 1 ppm Increments
- Nitrogen Dioxide: 0 to 30 ppm in 0.1 ppm Increments
Mounting
- On DIN Rail
- Rack-Mounted
- Wall Mounted
Power Supply
- Main: 0.8 A at 230 Vac
- Main: 1.5 A at 115 Vac
- Main: 85-264 Vac
- Module: 12-30 Vac
Relay Output
- Number of Relays: 4 Relays (CPS RM4)
- Number of Relays: 8 Relays (CPS RM8)
Storage Temperature
- -20° to 85° C (-4° to 185° F)