Yodify Product Library
Instantly add the Fluke 374 FC True-RMS AC/DC Clamp Meter and 50,000+ more product series to your store or catalog
Book Your Demo and See How
or create your store
Fluke 374 FC True-RMS AC/DC Clamp Meter
Brand: Fluke CorporationThe Fluke 374 FC, part of the Fluke Connect family of wireless test tools, delivers the standard features you need for everyday troubleshooting.
Measure AC and DC current to 600 A with the fixed jaw clamp or add an optional iFlex® flexible current probe to measure all the way to 2500 A.
The large diameter and flexible design of the iFlex probe make it easier to measure around large conductors in tight spaces or to access tightly packed wires.
You can also use the 374 FC to measure AC and DC voltage to 1000 V and resistance to 6000 Ω.
The 374 FC is Fluke Connect-enabled to wirelessly transmit results via Bluetooth to Apple and Android devices. That means you can read the results out of the arc flash zone, wearing less PPE.
You can even save results to the cloud and create and send reports in email right from the field. Or converse in real-time with ShareLive™ video calls.
Features- Advanced clamp meter that transmits measurements to your smartphone via Fluke Connect® for viewing at a safer distance
- Performs AC and DC current measurements to 600 A, and AC and DC voltage measurements to 1000 V
- Measures AC current to 2500 A AC with optional iFlex flexible current probe
- Measures resistance to 6000 Ω with continuity detection
Specifications
Brand
DC Current
- Range: 600.0 A
- Resolution: 0.1 A
- Accuracy: 2 % ± 5-digits
AC/DC Voltage
- Range: 1000 V
- Resolution: 0.1 V (≤ 600.0 V), 1 V (≤ 1000 V)
- Accuracy: 1.5 % ± 5-digits
mV dc
- Range: 500.0 mV
- Resolution: 0.1 mV
- Accuracy: 1 % ± 5-digits
Resistance
- Range: 6000 Ω
- Resolution: 0.1 Ω (≤ 600 Ω), 1 Ω (≤ 6000 Ω)
- Accuracy: 1 % ± 5-digits
Capacitance
- Range: 1000 μF
- Resolution: 0.1 μF (≤ 100 μF), 1 μ F (≤ 1000 μF)
- Accuracy: 1 % ± 4-digits
Operating Temperature
- -10° C to +50° C
Operating Humidity
- ≤ 90 % RH (at 10° C to 30° C)
- ≤ 75 % RH (at 30° C to 40° C)
- ≤ 45 % RH (at 40° C to 50° C)
Safety
- IEC 61010-1, Pollution Degree 2
- IEC 61010-2-032: CAT III 1000 V / CAT IV 600 V
- IEC 61010-2-033: CAT III 1000 V / CAT IV 600 V
IP Rating
- IEC 60529: IP30, non-operating