3051SFA Annubar Flowmeter
Brand: RosemountThe Rosemount 3051SFA Annubar Flow Meter is a no-equal solution with a patented, averaging pitot tube that delivers superior measurement accuracy over a wide flow range.
This flow meter can measure multiple variables and is engineered with an integrated thermowell for temperature measurement. Its patented T-shaped sensor is capable of obtaining measurements via a single pipe penetration while maintaining a small profile in the pipe to reduce permanent pressure loss and increase energy savings.
Features- Designed with built-in flow calculations for direct reporting of fully-compensated mass flow
- Patented T-shape sensor creates a fixed separation point for DP signal improvement over a wider flow rate
- Advanced diagnostics provide diagnostic coverage to detect abnormal process conditions and electrical loop issues
- Callendar-Van Dusen sensor matching improves temperature accuracy enabling best-in-class flow calculations
- Ultra for Flow performance class enables optimized flow measurement with a Ā±0.04% of reading accuracy
- T-shape Annubar design features very low permanent pressure loss
- Integral thermowell of sensor adds process temperature measurement without additional pipe penetrations
- All-welded, SuperModuleā¢ design offers industry-leading accuracy in harsh environments and applications
- Flowmeters come fully configured, leak-tested and ready to install right out of the box for fast installation
- Sensor stagnation zone positioned to reduce noise, measurement inaccuracies and keeps particulates from clogging
- SIL 2/3 certified to IEC 61508 (via 3rd party) and prior-use certificate of FMEDA data for safety installations
Specifications
Brand
Accuracy
- Ā± 0.8 % of Flow Rate at 14: 1 Flow Turndown
- Ā± 0.95 % of Flow Rate at 8: 1 Flow Rate
- Ā± 1.15 % of Flow Rate at 8: 1 Flow Turndown
Alarm
- Custom Alarm & Saturation Signal Levels
- NAMUR Alarm & Saturation Signal Levels
Ambient Temperature Range
- -40Ā° to 85Ā° C (-40Ā° to 185Ā° F)
Applications
- Marine & Offshore Applications
Approvals & Certifications
- ATEX
- CSA
- FM
- IEC Ex
- TIIS
Conduit Connection
- A Size Mini, 4-Pin Male Connector (minifast)
- M12, 4-Pin, Male Connector (eurofast)
Configuration
- 4-20 mA HART
- FOUNDATION Fieldbus Protocols
- Wireless Protocols
Damping Adjustment
- User Configurable from 0 to 60 seconds
Diaphragm Material
- No Diaphragm
Display
- PlantWeb LCD Display
- Remote Mount LCD Display & Interface
Drain, Vent Position
- Without Drain/Vent
Electrical Connectors
- 1/2ā NPT
- G 1/2ā
- M20 x 1.5
Electromagnetic Interference Effect
- Meets All Relevant Requirements of EN 61326 & NAMUR NE-21
Enclosure Finish
- Polyurethane Paint
Enclosure, Body Material
- 316 Stainless Steel
- Aluminum
Environmental Protection
- IP66
- IP68
- NEMA 4X
Fill Material
- Inert Oil Fill
- Silicone Oil
Flange Material
- 316 Stainless Steel
- Hastelloy C-276
Flange Size - 10” (DN 250)
- 10ā (DN 250) - 150#
- 10ā (DN 250) - 1500#
- 10ā (DN 250) - 2500#
- 10ā (DN 250) - 300#
- 10ā (DN 250) - 600#
- 10ā (DN 250) - 900#
- 10ā (DN 250) - PN 100
- 10ā (DN 250) - PN 16
- 10ā (DN 250) - PN 40
Flange Size - 12” (DN 300)
- 12ā (DN 300) - 150#
- 12ā (DN 300) - 1500#
- 12ā (DN 300) - 2500#
- 12ā (DN 300) - 300#
- 12ā (DN 300) - 600#
- 12ā (DN 300) - 900#
- 12ā (DN 300) - PN 100
- 12ā (DN 300) - PN 16
- 12ā (DN 300) - PN 40
Flange Size - 14” (DN 350)
- 14ā (DN 330) - 1500#
- 14ā (DN 350) - 150#
- 14ā (DN 350) - 2500#
- 14ā (DN 350) - 300#
- 14ā (DN 350) - 600#
- 14ā (DN 350) - 900#
- 14ā (DN 350) - PN 100
- 14ā (DN 350) - PN 16
- 14ā (DN 350) - PN 40
Flange Size - 16” (DN 400)
- 16ā (DN 400) - 150#
- 16ā (DN 400) - 1500#
- 16ā (DN 400) - 2500#
- 16ā (DN 400) - 300#
- 16ā (DN 400) - 600#
- 16ā (DN 400) - 900#
- 16ā (DN 400) - PN 100
- 16ā (DN 400) - PN 16
- 16ā (DN 400) - PN 40
Flange Size - 18” (DN 450)
- 18ā (DN 450) - 150#
- 18ā (DN 450) - 1500#
- 18ā (DN 450) - 2500#
- 18ā (DN 450) - 300#
- 18ā (DN 450) - 600#
- 18ā (DN 450) - 900#
- 18ā (DN 450) - PN 100
- 18ā (DN 450) - PN 16
- 18ā (DN 450) - PN 40
Flange Size - 2-1/2” (DN 65)
- 2-1/2ā (DN 65) - 150#
- 2-1/2ā (DN 65) - 1500#
- 2-1/2ā (DN 65) - 2500#
- 2-1/2ā (DN 65) - 300#
- 2-1/2ā (DN 65) - 600#
- 2-1/2ā (DN 65) - 900#
- 2-1/2ā (DN 65) - PN 100
- 2-1/2ā (DN 65) - PN 16
- 2-1/2ā (DN 65) - PN 40
Flange Size - 2” (DN 50)
- 2ā (DN 50) - 150#
- 2ā (DN 50) - 1500#
- 2ā (DN 50) - 2500#
- 2ā (DN 50) - 300#
- 2ā (DN 50) - 600#
- 2ā (DN 50) - 900#
- 2ā (DN 50) - PN 100
- 2ā (DN 50) - PN 16
- 2ā (DN 50) - PN 40
Flange Size - 20” (DN 500)
- 20ā (DN 500) - 150#
- 20ā (DN 500) - 1500#
- 20ā (DN 500) - 2500#
- 20ā (DN 500) - 300#
- 20ā (DN 500) - 600#
- 20ā (DN 500) - 900#
- 20ā (DN 500) - PN 100
- 20ā (DN 500) - PN 16
- 20ā (DN 500) - PN 40
Flange Size - 24” (DN 600)
- 24ā (DN 600) - 150#
- 24ā (DN 600) - 1500#
- 24ā (DN 600) - 2500#
- 24ā (DN 600) - 300#
- 24ā (DN 600) - 600#
- 24ā (DN 600) - 900#
- 24ā (DN 600) - PN 100
- 24ā (DN 600) - PN 16
Flange Size - 3-1/2” (DN 90)
- 3-1/2ā (DN 30) - 1500#
- 3-1/2ā (DN 30) - 2500#
- 3-1/2ā (DN 30) - 300#
- 3-1/2ā (DN 30) - 600#
- 3-1/2ā (DN 30) - 900#
- 3-1/2ā (DN 30) - PN 100
- 3-1/2ā (DN 30) - PN 16
- 3-1/2ā (DN 30) - PN 40
- 3-1/2ā (DN 90) - 150#
Flange Size - 3” (DN 80)
- 3ā (DN 80) - 150#
- 3ā (DN 80) - 1500#
- 3ā (DN 80) - 2500#
- 3ā (DN 80) - 300#
- 3ā (DN 80) - 600#
- 3ā (DN 80) - 900#
- 3ā (DN 80) - PN 100
- 3ā (DN 80) - PN 16
- 3ā (DN 80) - PN 40
Flange Size - 30” (DN 750)
- 30ā (DN 750) - 150#
- 30ā (DN 750) - 1500#
- 30ā (DN 750) - 2500#
- 30ā (DN 750) - 300#
- 30ā (DN 750) - 600#
- 30ā (DN 750) - 900#
- 30ā (DN 750) - PN 100
- 30ā (DN 750) - PN 40
- 30ā (DN 750) - PN 16
Flange Size - 36” (DN 900)
- 36ā (DN 900) - 150#
- 36ā (DN 900) - 1500#
- 36ā (DN 900) - 2500#
- 36ā (DN 900) - 300#
- 36ā (DN 900) - 600#
- 36ā (DN 900) - 900#
- 36ā (DN 900) - PN 100
- 36ā (DN 900) - PN 16
- 36ā (DN 900) - PN 40
Flange Size - 4” (DN 100)
- 4ā (DN 100) - 150#
- 4ā (DN 100) - 1500#
- 4ā (DN 100) - 2500#
- 4ā (DN 100) - 300#
- 4ā (DN 100) - 600#
- 4ā (DN 100) - 900#
- 4ā (DN 100) - PN 100
- 4ā (DN 100) - PN 16
- 4ā (DN 100) - PN 40
Flange Size - 42” (DN 1050)
- 42ā (DN 1050) - 1500#
- 42ā (DN 1050) - 2500#
- 42ā (DN 1050) - 300#
- 42ā (DN 1050) - 600#
- 42ā (DN 1050) - 900#
- 42ā (DN 1050) - ASME Class 150#
- 42ā (DN 1050) - PN 100
- 42ā (DN 1050) - PN 16
- 42ā (DN 1050) - PN 40
Flange Size - 48” (DN 1200)
- 48ā (DN 1200) - 150#
- 48ā (DN 1200) - 1500#
- 48ā (DN 1200) - 2500#
- 48ā (DN 1200) - 300#
- 48ā (DN 1200) - 600#
- 48ā (DN 1200) - 900#
- 48ā (DN 1200) - PN 100
- 48ā (DN 1200) - PN 16
- 48ā (DN 1200) - PN 40
Flange Size - 5” (DN 125)
- 5ā (DN 125) - 150#
- 5ā (DN 125) - 1500#
- 5ā (DN 125) - 2500#
- 5ā (DN 125) - 300#
- 5ā (DN 125) - 600#
- 5ā (DN 125) - 900#
- 5ā (DN 125) - PN 100
- 5ā (DN 125) - PN 16
- 5ā (DN 125) - PN 40
Flange Size - 6” (DN 150)
- 6ā (DN 150) - 150#
- 6ā (DN 150) - 1500#
- 6ā (DN 150) - 2500#
- 6ā (DN 150) - 300#
- 6ā (DN 150) - 600#
- 6ā (DN 150) - 900#
- 6ā (DN 150) - PN 100
- 6ā (DN 150) - PN 16
- 6ā (DN 150) - PN 40
Flange Size - 60” (DN 1500)
- 60ā (DN 1500) - 150#
- 60ā (DN 1500) - 1500#
- 60ā (DN 1500) - 2500#
- 60ā (DN 1500) - 300#
- 60ā (DN 1500) - 600#
- 60ā (DN 1500) - 900#
- 60ā (DN 1500) - PN 100
- 60ā (DN 1500) - PN 16
- 60ā (DN 1500) - PN 40
Flange Size - 7” (DN 175)
- 7ā (DN 175) - 150#
- 7ā (DN 175) - 1500#
- 7ā (DN 175) - 2500#
- 7ā (DN 175) - 300#
- 7ā (DN 175) - 600#
- 7ā (DN 175) - 900#
- 7ā (DN 175) - PN 100
- 7ā (DN 175) - PN 16
- 7ā (DN 175) - PN 40
Flange Size - 72” (DN 1800)
- 72ā (DN 1800) - 150#
- 72ā (DN 1800) - 1500#
- 72ā (DN 1800) - 2500#
- 72ā (DN 1800) - 300#
- 72ā (DN 1800) - 600#
- 72ā (DN 1800) - 900#
- 72ā (DN 1800) - PN 100
- 72ā (DN 1800) - PN 16
- 72ā (DN 1800) - PN 40
Flange Size - 78” (DN 1950)
- 78ā (DN 1950) - 150#
- 78ā (DN 1950) - 1500#
- 78ā (DN 1950) - 2500#
- 78ā (DN 1950) - 300#
- 78ā (DN 1950) - 600#
- 78ā (DN 1950) - 900#
- 78ā (DN 1950) - PN 100
- 78ā (DN 1950) - PN 16
- 78ā (DN 1950) - PN 40
Flange Size - 8” (DN 200)
- 8ā (DN 200) - 150#
- 8ā (DN 200) - 1500#
- 8ā (DN 200) - 2500#
- 8ā (DN 200) - 300#
- 8ā (DN 200) - 600#
- 8ā (DN 200) - 900#
- 8ā (DN 200) - PN 100
- 8ā (DN 200) - PN 16
- 8ā (DN 200) - PN 40
Flange Size - 84” (DN 2100)
- 84ā (DN 2100) - 150#
- 84ā (DN 2100) - 1500#
- 84ā (DN 2100) - 2500#
- 84ā (DN 2100) - 300#
- 84ā (DN 2100) - 600#
- 84ā (DN 2100) - 900#
- 84ā (DN 2100) - PN 100
- 84ā (DN 2100) - PN 16
- 84ā (DN 2100) - PN 40
Flange Size - 90” (DN 2250)
- 90ā (DN 2250) - 150#
- 90ā (DN 2250) - 1500#
- 90ā (DN 2250) - 2500#
- 90ā (DN 2250) - 300#
- 90ā (DN 2250) - 600#
- 90ā (DN 2250) - 900#
- 90ā (DN 2250) - PN 100
- 90ā (DN 2250) - PN 16
- 90ā (DN 2250) - PN 40
Flange Size - 96” (DN 2400)
- 96ā (DN 2400) - 150#
- 96ā (DN 2400) - 1500#
- 96ā (DN 2400) - 2500#
- 96ā (DN 2400) - 300#
- 96ā (DN 2400) - 600#
- 96ā (DN 2400) - 900#
- 96ā (DN 2400) - PN 100
- 96ā (DN 2400) - PN 16
- 96ā (DN 2400) - PN 40
Humidity
- 0 to 100 % Relative Humidity
Input Power
- 4-20 mA HART: 10.5-42.4 Vdc
- FOUNDATION Fieldbus: 9-32 Vdc
Mounting
- 150# ANSI
- 1500# ANSI
- 2500# ANSI
- 300# ANSI
- 600# ANSI
- 900# ANSI
- DN PN 100 Flange
- DN PN 16 Flange
- DN PN 40 Flange
NACE & NIST
- NACE MR-0175
O-Ring Material
- Glass-Filled PTFE
- Graphite-Filled PTFE
Output
- 2.4 GHz DSSS
- 2-Wire 4-20 mA
Overpressure & Static Pressure Limits
- psia: 0.5 to 3,626 (bar: 0.03 to 250, kPa: 3.447 to 25,000)
Power Supply Effect
- < Ā± 0.005 % of Calibrated Span Per Volt Change in Voltage at the Transmitter Terminals
Pressure Range
- bar: 0.979 to 250
- Inches WC: 0 to 1,000 (mbar: 0 to 2488)
- kPa: 97.91 to 25,000
- psi: -14.2 to 3,626
Pressure Type
- Absolute
- Differential
- Gauge
Process Temperature
- -40Ā° to 149Ā° C (-40Ā° to 300Ā° F)
Storage Temperature
- -40Ā° to 85Ā° C (-40Ā° to 185Ā° F)
Vibration Effect
- > Ā± 0.1 % of URL
Volumetric Displacement
- > 0.005āĀ³ (0.08 cmĀ³)
Wetted Materials
- 316 Stainless Steel
- Hastelloy C-276
Documentation
Data Sheets
Product Manuals
- Manual Supplement: Rosemount 3051S Series Pressure Transmitter with FOUNDATION Fieldbus Protocol pdf 2.5 MB
- Manual: Rosemount 3051S Series Pressure Transmitter with HART Protocol pdf 10.2 MB
- Manual: The Rosemount Annubar Flowmeter Series (Part 1) pdf 35 KB
- Manual: The Rosemount Annubar Flowmeter Series (Part 2) pdf 19 KB
- Manual: The Rosemount Annubar Flowmeter Series (Part 3) pdf 436 KB
- Manual: The Rosemount Annubar Flowmeter Series (Part 4) pdf 7.5 MB
- Manual: The Rosemount Annubar Flowmeter Series (Part 5) pdf 719 KB
- Manual: The Rosemount Annubar Flowmeter Series (Part 6) pdf 230 KB
- Manual: The Rosemount Annubar Flowmeter Series (Part 7) pdf 2.1 MB
- Manual: The Rosemount Annubar Flowmeter Series (Part 8) pdf 2.2 MB
- Quick Start Guide: Rosemount 3051S MultiVariable Transmitter and 3051SF Series Flowmeter MultiVariable Transmitter with HART Protocol pdf 3.6 MB
- Quick Start Guide: Rosemount 3051S MultiVariable Transmitter and 3051SF Series MultiVariable Flowmeter with FOUNDATION Fieldbus Protocol pdf 3.5 MB
- Quick Start Guide: Rosemount 3051S Series Pressure Transmitter and 3051SF Series Flowmeter with FOUNDATION fieldbus Protocol pdf 2.0 MB
- Quick Start Guide: Rosemount 3051S Series Pressure Transmitter and 3051SF Series Flowmeter with HART Protocol pdf 3.3 MB
- Quick Start Guide: Rosemount 3051S Series Pressure Transmitter with Wireless Enabled HART Solutions, Rosemount 3051SF Series Flowmeter Transmitter with Wireless Enabled HART Solutions pdf 1.5 MB
- RM 3051SFA Annubar Flowmeter Product Manual pdf 19.3 MB
Certificates & Approvals
- Declaration of Conformity: Rosemount Annubar, ProBar, Mass ProBar, ProPlate, Mass ProPlate, 405, 1195, 1495, 1496, 1497 pdf 454 KB
- FMEDA Report: Rosemount 3051S 4-20mA HART Pressure Transmitter pdf 399 KB
- Product Certificate: Failure Modes, Effects and Diagnostic Analysis pdf 622 KB
- Product Certificate: IEC 61508 Functional Safety Assessment pdf 364 KB
- Product Certificate: IEC 61508 Safety Certificate pdf 252 KB
- Product Certificate: Primary Elements pdf 253 KB
- Product Certificate: Rosemount 3051S HART Advanced Diagnostics Pressure Transmitter, option code DA2 pdf 426 KB
- Product Certificate: Rosemount 3051S HART Diagnostics Pressure Transmitter, option code DA2 Sensor Software Revision 5 or 6 pdf 999 KB
- Product Certificate: Rosemount 3051S Pressure Transmitter with Advanced HART Diagnostics, Sensor Software Revision 5.0 and Above pdf 405 KB
- Product Safety Certificate: Rosemount 3051S 4-20mA HART Pressure Transmitter pdf 404 KB
Drawings & Schematics
- Type 1 Drawing: Rosemount 3051SFA Pak-Lok Mounting type Sensor Size 1, 2D PDF pdf 10.0 MB
- Type 1 Drawing: Rosemount 3051SFA Pak-Lok Mounting Type Sensor Size 1, 3D PDF pdf 566 KB
- Type 1 Drawing: Rosemount 3051SFA Pak-Lok Mounting type Sensor Size 1, 3D SAT stp 1.4 MB
- Type 1 Drawing: Rosemount 3051SFA Pak-Lok Mounting type Sensor Size 1, 3D STP stp 1.4 MB
- Type 1 Drawing: Rosemount 3051SFA Pak-Lok Mounting type Sensor Size 2, 2D PDF pdf 8.3 MB
- Type 1 Drawing: Rosemount 3051SFA Pak-Lok Mounting type Sensor Size 2, 3D PDF pdf 562 KB
- Type 1 Drawing: Rosemount 3051SFA Pak-Lok Mounting type Sensor Size 2, 3D SAT sat 1.4 MB
- Type 1 Drawing: Rosemount 3051SFA Pak-Lok Mounting type Sensor Size 2, 3D STP stp 1.4 MB
- Type 1 Drawing: Rosemount 3051SFA Pak-Lok Mounting type Sensor Size 3, 2D PDF pdf 5.0 MB
- Type 1 Drawing: Rosemount 3051SFA Pak-Lok Mounting type Sensor Size 3, 3D PDF pdf 544 KB
- Type 1 Drawing: Rosemount 3051SFA Pak-Lok Mounting type Sensor Size 3, 3D SAT sat 1.3 MB
- Type 1 Drawing: Rosemount 3051SFA Pak-Lok Mounting type Sensor Size 3, 3D STP stp 1.3 MB
- Type 1 Drawing: Rosemount 485 Annubar Flow Meter (3051SFA, 3051CFA, 2051CFA, 3095MFA) Sensor Size 1 Flanged/Threaded Flo-Tap 150#-600# ANSI, 2D PDF pdf 1.1 MB
- Type 1 Drawing: Rosemount 485 Annubar Flow Meter (3051SFA, 3051CFA, 2051CFA, 3095MFA) Sensor Size 2 Flanged/Threaded Flo-Tap 150#-600# ANSI, 2D PDF pdf 3.0 MB
- Type 1 Drawing: Rosemount 485 Annubar Flow Meter (3051SFA, 3051CFA, 2051CFA, 3095MFA) Sensor Size 3 Flanged/Threaded Flo-Tap 150#-600# ANSI, 2D PDF pdf 2.5 MB
- Type 1 Drawing: Rosemount 485 ANNUBAR Flowmeter (3051SFA, 3051CFA, 2051CFA, 3095MFA) Sensor Size 1 Flanged 150#-2500# ANSI, 2D PDF pdf 1.3 MB
- Type 1 Drawing: Rosemount 485 ANNUBAR Flowmeter (3051SFA, 3051CFA, 2051CFA, 3095MFA) Sensor Size 1 Flanged 150#-2500# ANSI, 3D PDF pdf 624 KB
- Type 1 Drawing: Rosemount 485 ANNUBAR Flowmeter (3051SFA, 3051CFA, 2051CFA, 3095MFA) Sensor Size 1 Flanged 150#-2500# ANSI, 3D SAT sat 1.7 MB
- Type 1 Drawing: Rosemount 485 ANNUBAR Flowmeter (3051SFA, 3051CFA, 2051CFA, 3095MFA) Sensor Size 1 Flanged 150#-2500# ANSI, 3D STP stp 1.6 MB
- Type 1 Drawing: Rosemount 485 Annubar Flowmeter (3051SFA, 3051CFA, 2051CFA, 3095MFA) SENSOR SIZE 1 PARK-LOK 150#-600# ANSI 3D PDF pdf 571 KB
- Type 1 Drawing: Rosemount 485 Annubar Flowmeter (3051SFA, 3051CFA, 2051CFA, 3095MFA) SENSOR SIZE 1 PARK-LOK 150#-600# ANSI, 2D PDF pdf 949 KB
- Type 1 Drawing: Rosemount 485 Annubar Flowmeter (3051SFA, 3051CFA, 2051CFA, 3095MFA) SENSOR SIZE 1 PARK-LOK 150#-600# ANSI, 3D SAT sat 1.5 MB
- Type 1 Drawing: Rosemount 485 Annubar Flowmeter (3051SFA, 3051CFA, 2051CFA, 3095MFA) SENSOR SIZE 2 FLANGE-LOK 150#-600# ANSI, 2D PDF pdf 992 KB
- Type 1 Drawing: Rosemount 485 Annubar Flowmeter (3051SFA, 3051CFA, 2051CFA, 3095MFA) SENSOR SIZE 2 FLANGE-LOK 150#-600# ANSI, 3D PDF pdf 470 KB
- Type 1 Drawing: Rosemount 485 Annubar Flowmeter (3051SFA, 3051CFA, 2051CFA, 3095MFA) SENSOR SIZE 2 FLANGE-LOK 150#-600# ANSI, 3D SAT sat 1.4 MB
- Type 1 Drawing: Rosemount 485 Annubar Flowmeter (3051SFA, 3051CFA, 2051CFA, 3095MFA) SENSOR SIZE 2 FLANGE-LOK 150#-600# ANSI, 3D STP stp 1.4 MB
- Type 1 Drawing: Rosemount 485 Annubar Flowmeter (3051SFA, 3051CFA, 2051CFA, 3095MFA) Sensor Size 2 Flanged 150#-2500# ANSI, 2D PDF pdf 1.9 MB
- Type 1 Drawing: Rosemount 485 Annubar Flowmeter (3051SFA, 3051CFA, 2051CFA, 3095MFA) Sensor Size 2 Flanged 150#-2500# ANSI, 3D PDF pdf 582 KB
- Type 1 Drawing: Rosemount 485 Annubar Flowmeter (3051SFA, 3051CFA, 2051CFA, 3095MFA) SENSOR SIZE 2 PAK-LOK 150# 600# ANSI, 2D PDF pdf 960 KB
- Type 1 Drawing: Rosemount 485 Annubar Flowmeter (3051SFA, 3051CFA, 2051CFA, 3095MFA) SENSOR SIZE 2 PAK-LOK 150#-600# ANSI, 3D PDF pdf 384 KB
- Type 1 Drawing: Rosemount 485 Annubar Flowmeter (3051SFA, 3051CFA, 2051CFA, 3095MFA) SENSOR SIZE 3 PAK-LOK 150#-600# ANSI, 2D PDF pdf 916 KB