Yodify Product Library
Instantly add the Wall-Mounting Sockets 32 A Series 8571/11 and 50,000+ more product series to yourĀ store or catalogĀ Ā
Book Your Demo and See How
or create your store
Wall-Mounting Sockets 32 A Series 8571/11
Brand: R. STAHL AGR. STAHL Series 8571/11 SolConeX sockets for Zone 1/21 in a 3-, 4- and 5-pole version have full AC-3switching capacity up to 32 A.
The high degree of protection IP66 guarantees the highest level of protection against the penetration of dust and/or water in any application position.
Self-cleaning lamellar contacts provide optimum contact and the plugs can be inserted and removed in the zero position quickly and easily.
The load disconnect switch, with mechanical locking device and a handle that can be locked in the 0 or I position, is an additional safety feature.
Features- Reliable load disconnect switch with clearly visible, lockable handle which also displays the switching position
- Optional auxiliary contacts for control and signaling purposes, pluggable
- With AC-3 motor switching capacity according to IEC/EN 60947-3
1 - 12 of 20 Part Numbers
150863
Reliable load disconnect switch with clearly visible, lockable handle which also displays the switching position
Optional auxiliary contacts for control and signalling purposes, pluggable
With AC-3 motor switching capacity according to IEC/EN 60947-3
Ambient Conditions
- Ambient temperature - -30 °C ... +55 °C -30 °C ... +40 °C
- Ambient temperature max. - +55 °C
- Ambient temperature max. note - max. 32 A
- Ambient temperature max. note 2 - max. 32 A
- Ambient temperature max.2 - +40 °C
- Ambient temperature min. - -30 °C
- Ambient temperature min. 2 - -30 °C
Components
- Cable diameter - 9.00 - 21.00 mm
- Cable entry note - positioning on the top or at the side, according to the order
- Entries - 2 x M32
- Material of screw connections - Polyamide, black
- Screw connections - 1 x M32
- Stopping plug - 1 x M32
- Stopping plug material - Polyamide, black
Electrical Data
- Auxiliary contacts available - No
- Frequency range - 50 - 60 Hz
- N-pole present - Yes
- Optional auxiliary contacts - Yes
- PE-pole present - Yes
- Rated operational current - 0.000 - 32.000 A
- Rated operational current - 32.000 A
- Rated operational voltage AC - 277.00 - 288.00 V / 480.00 - 500.00 V
- Rated operational voltage AC - 288.00 V
- Rated operational voltage AC - 277.00 - 288.00 V
- Rated operational voltage AC 2 - 480.00 - 500.00 V
- Type of voltage - Low voltage
Explosion Protection
- Ambient temperature °C - -30 - 55 °C
- Ambient temperature °C 2 - -30 - 40 °C
- Application range (zones) - 1, 2, 21, 22
- ATEX dust certificate - PTB 04 ATEX 1060
- ATEX gas certificate - PTB 04 ATEX 1060
- Certificate EAC - TS RU S-DE.GB04.B.00282
- Certificates - ATEX (PTB), Brazil (ULB), EAC (STV), IECEx (PTB)
- Dust explosion protection ATEX - II 2 D Ex tb IIIC T75 °C Db
- Dust Explosion Protection ATEX 2 - II 2 D Ex tb IIIC T60 °C Db
- Dust explosion protection EAC - Ex tD A21 IP 66 T60 °C, T75 °C
- Dust explosion protection IECEx - Ex tb IIIC T75 °C Db
- Dust explosion protection IECEx 2 - Ex tb IIIC T60 °C Db
- Gas explosion protection ATEX - II 2 G Ex db eb IIC T5 Gb
- Gas explosion protection ATEX 2 - II 2 G Ex db eb IIC T6 Gb
- Gas explosion protection EAC - 2 Ex de IIC T6/T5 2 Ex de [ia] IIC T6/T5
- Gas explosion protection IECEx - Ex db eb IIC T5 Gb
- Gas explosion protection IECEx 2 - Ex db eb IIC T6 Gb
- IECEX dust certificate - IECEx PTB 05.0024
- IECEX gas certificate - IECEx PTB 05.0024
- Languages of the documentation - English, German
General
- Functional Description - R. STAHL Series 8571/11 SolConeX sockets for Zone 1/21 in a 3-, 4- and 5-pole version have full AC-3 switching capacity up to 32 A. The high degree of protection IP66 guarantees the highest level of protection against the penetration of dust and/or water in any application position. Self-cleaning lamellar contacts provide optimum contact and the plugs can be inserted and removed in the zero position quickly and easily. The load disconnect switch, with mechanical locking device and a handle that can be locked in the 0 or I position, is an additional safety feature.
- Highlights - Reliable load disconnect switch with clearly visible, lockable handle which also displays the switching position Optional auxiliary contacts for control and signalling purposes, pluggable With AC-3 motor switching capacity according to IEC/EN 60947-3
- Product Description - Switch socket
- Product Type - 8571/11-507
- Title Product Variant Technical Data - 8571/11-507 WS 277/480-288/500V, 50/60Hz
- WebCode - 8571A
Mechanical Data
- Coding (clock hour position) - 7
- Colour code - black
- Connection terminals finely-stranded max. - 2 x 6,00 mm2
- Connection terminals min. - 2.50 mm²
- Connection terminals solid max. - 2 x 10,00 mm2
- Degree of protection (IP) - IP66
- Degree of protection note - according to IEC/EN 60529
- Detailed number of poles - 5 P (3 P + N + PE)
- Enclosure material - Polyamide, Glass fibre reinforced
- Height - 207.000 mm
- Length - 281.000 mm
- Lockable in - in 0- and I-position
- Series - SolConeX
- Silicone-free - Yes
- Type of connection cable - Finely stranded, solid
- Weight - 2.200 kg
- Width - 135.000 mm
150870
Reliable load disconnect switch with clearly visible, lockable handle which also displays the switching position
Optional auxiliary contacts for control and signalling purposes, pluggable
With AC-3 motor switching capacity according to IEC/EN 60947-3
Ambient Conditions
- Ambient temperature - -30 °C ... +55 °C -30 °C ... +40 °C
- Ambient temperature max. - +55 °C
- Ambient temperature max. note - max. 32 A
- Ambient temperature max. note 2 - max. 32 A
- Ambient temperature max.2 - +40 °C
- Ambient temperature min. - -30 °C
- Ambient temperature min. 2 - -30 °C
Components
- Cable diameter - 9.00 - 21.00 mm
- Cable entry note - positioning on the top or at the side, according to the order
- Entries - 2 x M32
- Material of screw connections - Polyamide, black
- Screw connections - 1 x M32
- Stopping plug - 1 x M32
- Stopping plug material - Polyamide, black
Electrical Data
- Auxiliary contacts available - No
- Frequency range - 50 - 60 Hz
- N-pole present - Yes
- Optional auxiliary contacts - Yes
- PE-pole present - Yes
- Rated operational current - 32.000 A
- Rated operational current - 0.000 - 32.000 A
- Rated operational voltage AC - 120.00 - 144.00 V
- Rated operational voltage AC - 144.00 V
- Rated operational voltage AC - 120.00 - 144.00 V / 208.00 - 250.00 V
- Rated operational voltage AC 2 - 208.00 - 250.00 V
- Type of voltage - Low voltage
Explosion Protection
- Ambient temperature °C - -30 - 55 °C
- Ambient temperature °C 2 - -30 - 40 °C
- Application range (zones) - 1, 2, 21, 22
- ATEX dust certificate - PTB 04 ATEX 1060
- ATEX gas certificate - PTB 04 ATEX 1060
- Certificate EAC - TS RU S-DE.GB04.B.00282
- Certificates - ATEX (PTB), Brazil (ULB), EAC (STV), IECEx (PTB)
- Dust explosion protection ATEX - II 2 D Ex tb IIIC T75 °C Db
- Dust Explosion Protection ATEX 2 - II 2 D Ex tb IIIC T60 °C Db
- Dust explosion protection EAC - Ex tD A21 IP 66 T60 °C, T75 °C
- Dust explosion protection IECEx - Ex tb IIIC T75 °C Db
- Dust explosion protection IECEx 2 - Ex tb IIIC T60 °C Db
- Gas explosion protection ATEX - II 2 G Ex db eb IIC T5 Gb
- Gas explosion protection ATEX 2 - II 2 G Ex db eb IIC T6 Gb
- Gas explosion protection EAC - 2 Ex de IIC T6/T5 2 Ex de [ia] IIC T6/T5
- Gas explosion protection IECEx - Ex db eb IIC T5 Gb
- Gas explosion protection IECEx 2 - Ex db eb IIC T6 Gb
- IECEX dust certificate - IECEx PTB 05.0024
- IECEX gas certificate - IECEx PTB 05.0024
- Languages of the documentation - English, German
General
- Functional Description - R. STAHL Series 8571/11 SolConeX sockets for Zone 1/21 in a 3-, 4- and 5-pole version have full AC-3 switching capacity up to 32 A. The high degree of protection IP66 guarantees the highest level of protection against the penetration of dust and/or water in any application position. Self-cleaning lamellar contacts provide optimum contact and the plugs can be inserted and removed in the zero position quickly and easily. The load disconnect switch, with mechanical locking device and a handle that can be locked in the 0 or I position, is an additional safety feature.
- Highlights - Reliable load disconnect switch with clearly visible, lockable handle which also displays the switching position Optional auxiliary contacts for control and signalling purposes, pluggable With AC-3 motor switching capacity according to IEC/EN 60947-3
- Product Description - Switch socket
- Product Type - 8571/11-509
- Title Product Variant Technical Data - 8571/11-509 WS 120/208-144/250V, 50/60Hz
- WebCode - 8571A
Mechanical Data
- Coding (clock hour position) - 9
- Colour code - blue
- Connection terminals finely-stranded max. - 2 x 6,00 mm2
- Connection terminals min. - 2.50 mm²
- Connection terminals solid max. - 2 x 10,00 mm2
- Degree of protection (IP) - IP66
- Degree of protection note - according to IEC/EN 60529
- Detailed number of poles - 5 P (3 P + N + PE)
- Enclosure material - Polyamide, Glass fibre reinforced
- Height - 207.000 mm
- Length - 281.000 mm
- Lockable in - in 0- and I-position
- Series - SolConeX
- Silicone-free - Yes
- Type of connection cable - Finely stranded, solid
- Weight - 2.200 kg
- Width - 135.000 mm
150876
Reliable load disconnect switch with clearly visible, lockable handle which also displays the switching position
Optional auxiliary contacts for control and signalling purposes, pluggable
With AC-3 motor switching capacity according to IEC/EN 60947-3
Ambient Conditions
- Ambient temperature - -30 °C ... +55 °C -30 °C ... +40 °C
- Ambient temperature max. - +55 °C
- Ambient temperature max. note - max. 32 A
- Ambient temperature max. note 2 - max. 32 A
- Ambient temperature max.2 - +40 °C
- Ambient temperature min. - -30 °C
- Ambient temperature min. 2 - -30 °C
Components
- Cable diameter - 9.00 - 21.00 mm
- Cable entry note - positioning on the top or at the side, according to the order
- Entries - 2 x M32
- Material of screw connections - Polyamide, black
- Screw connections - 1 x M32
- Stopping plug - 1 x M32
- Stopping plug material - Polyamide, black
Electrical Data
- Auxiliary contacts available - No
- Frequency range - 50 - 60 Hz
- N-pole present - Yes
- Optional auxiliary contacts - Yes
- PE-pole present - Yes
- Rated operational current - 32.000 A
- Rated operational current - 0.000 - 32.000 A
- Rated operational voltage AC - 400.00 V
- Rated operational voltage AC - 347.00 - 400.00 V
- Rated operational voltage AC - 347.00 - 400.00 V / 600.00 - 690.00 V
- Rated operational voltage AC 2 - 600.00 - 690.00 V
- Type of voltage - Low voltage
Explosion Protection
- Ambient temperature °C - -30 - 55 °C
- Ambient temperature °C 2 - -30 - 40 °C
- Application range (zones) - 1, 2, 21, 22
- ATEX dust certificate - PTB 04 ATEX 1060
- ATEX gas certificate - PTB 04 ATEX 1060
- Certificate EAC - TS RU S-DE.GB04.B.00282
- Certificates - ATEX (PTB), Brazil (ULB), EAC (STV), IECEx (PTB)
- Dust explosion protection ATEX - II 2 D Ex tb IIIC T75 °C Db
- Dust Explosion Protection ATEX 2 - II 2 D Ex tb IIIC T60 °C Db
- Dust explosion protection EAC - Ex tD A21 IP 66 T60 °C, T75 °C
- Dust explosion protection IECEx - Ex tb IIIC T75 °C Db
- Dust explosion protection IECEx 2 - Ex tb IIIC T60 °C Db
- Gas explosion protection ATEX - II 2 G Ex db eb IIC T5 Gb
- Gas explosion protection ATEX 2 - II 2 G Ex db eb IIC T6 Gb
- Gas explosion protection EAC - 2 Ex de IIC T6/T5 2 Ex de [ia] IIC T6/T5
- Gas explosion protection IECEx - Ex db eb IIC T5 Gb
- Gas explosion protection IECEx 2 - Ex db eb IIC T6 Gb
- IECEX dust certificate - IECEx PTB 05.0024
- IECEX gas certificate - IECEx PTB 05.0024
- Languages of the documentation - English, German
General
- Functional Description - R. STAHL Series 8571/11 SolConeX sockets for Zone 1/21 in a 3-, 4- and 5-pole version have full AC-3 switching capacity up to 32 A. The high degree of protection IP66 guarantees the highest level of protection against the penetration of dust and/or water in any application position. Self-cleaning lamellar contacts provide optimum contact and the plugs can be inserted and removed in the zero position quickly and easily. The load disconnect switch, with mechanical locking device and a handle that can be locked in the 0 or I position, is an additional safety feature.
- Highlights - Reliable load disconnect switch with clearly visible, lockable handle which also displays the switching position Optional auxiliary contacts for control and signalling purposes, pluggable With AC-3 motor switching capacity according to IEC/EN 60947-3
- Product Description - Switch socket
- Product Type - 8571/11-505
- Title Product Variant Technical Data - 8571/11-505 WS 347/600-400/690V ,50/60Hz
- WebCode - 8571A
Mechanical Data
- Coding (clock hour position) - 5
- Colour code - black
- Connection terminals finely-stranded max. - 2 x 6,00 mm2
- Connection terminals min. - 2.50 mm²
- Connection terminals solid max. - 2 x 10,00 mm2
- Degree of protection (IP) - IP66
- Degree of protection note - according to IEC/EN 60529
- Detailed number of poles - 5 P (3 P + N + PE)
- Enclosure material - Polyamide, Glass fibre reinforced
- Height - 207.000 mm
- Length - 281.000 mm
- Lockable in - in 0- and I-position
- Series - SolConeX
- Silicone-free - Yes
- Type of connection cable - Finely stranded, solid
- Weight - 2.200 kg
- Width - 135.000 mm
150882
Reliable load disconnect switch with clearly visible, lockable handle which also displays the switching position
Optional auxiliary contacts for control and signalling purposes, pluggable
With AC-3 motor switching capacity according to IEC/EN 60947-3
Ambient Conditions
- Ambient temperature - -30 °C ... +55 °C -30 °C ... +40 °C
- Ambient temperature max. - +55 °C
- Ambient temperature max. note - max. 32 A
- Ambient temperature max. note 2 - max. 32 A
- Ambient temperature max.2 - +40 °C
- Ambient temperature min. - -30 °C
- Ambient temperature min. 2 - -30 °C
Components
- Cable diameter - 9.00 - 21.00 mm
- Cable entry note - positioning on the top or at the side, according to the order
- Entries - 2 x M32
- Material of screw connections - Polyamide, black
- Screw connections - 1 x M32
- Stopping plug - 1 x M32
- Stopping plug material - Polyamide, black
Electrical Data
- Auxiliary contacts available - No
- Frequency range - 60 - 60 Hz
- N-pole present - Yes
- Optional auxiliary contacts - Yes
- PE-pole present - Yes
- Rated operational current - 32.000 A
- Rated operational voltage AC - 250.00 - 265.00 V
- Rated operational voltage AC 2 - 250.00 - 440.00 V
- Type of voltage - Low voltage
Explosion Protection
- Ambient temperature °C - -30 - 55 °C
- Ambient temperature °C 2 - -30 - 40 °C
- Application range (zones) - 1, 2, 21, 22
- ATEX dust certificate - PTB 04 ATEX 1060
- ATEX gas certificate - PTB 04 ATEX 1060
- Certificate EAC - TS RU S-DE.GB04.B.00282
- Certificates - ATEX (PTB), Brazil (ULB), EAC (STV), IECEx (PTB)
- Dust explosion protection ATEX - II 2 D Ex tb IIIC T75 °C Db
- Dust Explosion Protection ATEX 2 - II 2 D Ex tb IIIC T60 °C Db
- Dust explosion protection EAC - Ex tD A21 IP 66 T60 °C, T75 °C
- Dust explosion protection IECEx - Ex tb IIIC T75 °C Db
- Dust explosion protection IECEx 2 - Ex tb IIIC T60 °C Db
- Gas explosion protection ATEX - II 2 G Ex db eb IIC T5 Gb
- Gas explosion protection ATEX 2 - II 2 G Ex db eb IIC T6 Gb
- Gas explosion protection EAC - 2 Ex de IIC T6/T5 2 Ex de [ia] IIC T6/T5
- Gas explosion protection IECEx - Ex db eb IIC T5 Gb
- Gas explosion protection IECEx 2 - Ex db eb IIC T6 Gb
- IECEX dust certificate - IECEx PTB 05.0024
- IECEX gas certificate - IECEx PTB 05.0024
- Languages of the documentation - English, German
General
- Functional Description - R. STAHL Series 8571/11 SolConeX sockets for Zone 1/21 in a 3-, 4- and 5-pole version have full AC-3 switching capacity up to 32 A. The high degree of protection IP66 guarantees the highest level of protection against the penetration of dust and/or water in any application position. Self-cleaning lamellar contacts provide optimum contact and the plugs can be inserted and removed in the zero position quickly and easily. The load disconnect switch, with mechanical locking device and a handle that can be locked in the 0 or I position, is an additional safety feature.
- Highlights - Reliable load disconnect switch with clearly visible, lockable handle which also displays the switching position Optional auxiliary contacts for control and signalling purposes, pluggable With AC-3 motor switching capacity according to IEC/EN 60947-3
- Product Description - Switch socket
- Product Type - 8571/11-511
- Title Product Variant Technical Data - 8571/11-511 WS 250/440-265/460V, 60Hz
- WebCode - 8571A
Mechanical Data
- Coding (clock hour position) - 11
- Colour code - red
- Connection terminals finely-stranded max. - 2 x 6,00 mm2
- Connection terminals min. - 2.50 mm²
- Connection terminals solid max. - 2 x 10,00 mm2
- Degree of protection (IP) - IP66
- Degree of protection note - according to IEC/EN 60529
- Detailed number of poles - 5 P (3 P + N + PE)
- Enclosure material - Polyamide, Glass fibre reinforced
- Height - 207.000 mm
- Length - 281.000 mm
- Lockable in - in 0- and I-position
- Series - SolConeX
- Silicone-free - Yes
- Type of connection cable - Finely stranded, solid
- Weight - 2.200 kg
- Width - 135.000 mm
150890
Reliable load disconnect switch with clearly visible, lockable handle which also displays the switching position
Optional auxiliary contacts for control and signalling purposes, pluggable
With AC-3 motor switching capacity according to IEC/EN 60947-3
Ambient Conditions
- Ambient temperature - -30 °C ... +55 °C -30 °C ... +40 °C
- Ambient temperature max. - +55 °C
- Ambient temperature max. note - max. 32 A
- Ambient temperature max. note 2 - max. 32 A
- Ambient temperature max.2 - +40 °C
- Ambient temperature min. - -30 °C
- Ambient temperature min. 2 - -30 °C
Components
- Cable diameter - 9.00 - 21.00 mm
- Cable entry note - positioning on the top or at the side, according to the order
- Entries - 2 x M32
- Material of screw connections - Polyamide, black
- Screw connections - 1 x M32
- Stopping plug - 1 x M32
- Stopping plug material - Polyamide, black
Electrical Data
- Auxiliary contacts available - No
- Frequency range - 50 - 60 Hz
- N-pole present - No
- Optional auxiliary contacts - Yes
- PE-pole present - Yes
- Rated operational current - 0.000 - 32.000 A
- Rated operational current - 32.000 A
- Rated operational voltage AC - 415.00 V
- Rated operational voltage AC - 380.00 - 415.00 V
- Type of voltage - Low voltage
Explosion Protection
- Ambient temperature °C - -30 - 55 °C
- Ambient temperature °C 2 - -30 - 40 °C
- Application range (zones) - 1, 2, 21, 22
- ATEX dust certificate - PTB 04 ATEX 1060
- ATEX gas certificate - PTB 04 ATEX 1060
- Certificate EAC - TS RU S-DE.GB04.B.00282
- Certificates - ATEX (PTB), Brazil (ULB), EAC (STV), IECEx (PTB)
- Dust explosion protection ATEX - II 2 D Ex tb IIIC T75 °C Db
- Dust Explosion Protection ATEX 2 - II 2 D Ex tb IIIC T60 °C Db
- Dust explosion protection EAC - Ex tD A21 IP 66 T60 °C, T75 °C
- Dust explosion protection IECEx - Ex tb IIIC T75 °C Db
- Dust explosion protection IECEx 2 - Ex tb IIIC T60 °C Db
- Gas explosion protection ATEX - II 2 G Ex db eb IIC T5 Gb
- Gas explosion protection ATEX 2 - II 2 G Ex db eb IIC T6 Gb
- Gas explosion protection EAC - 2 Ex de IIC T6/T5 2 Ex de [ia] IIC T6/T5
- Gas explosion protection IECEx - Ex db eb IIC T5 Gb
- Gas explosion protection IECEx 2 - Ex db eb IIC T6 Gb
- IECEX dust certificate - IECEx PTB 05.0024
- IECEX gas certificate - IECEx PTB 05.0024
- Languages of the documentation - English, German
General
- Functional Description - R. STAHL Series 8571/11 SolConeX sockets for Zone 1/21 in a 3-, 4- and 5-pole version have full AC-3 switching capacity up to 32 A. The high degree of protection IP66 guarantees the highest level of protection against the penetration of dust and/or water in any application position. Self-cleaning lamellar contacts provide optimum contact and the plugs can be inserted and removed in the zero position quickly and easily. The load disconnect switch, with mechanical locking device and a handle that can be locked in the 0 or I position, is an additional safety feature.
- Highlights - Reliable load disconnect switch with clearly visible, lockable handle which also displays the switching position Optional auxiliary contacts for control and signalling purposes, pluggable With AC-3 motor switching capacity according to IEC/EN 60947-3
- Product Description - Switch socket
- Product Type - 8571/11-406
- Title Product Variant Technical Data - 8571/11-406 WS 380-415V, 50/60Hz
- WebCode - 8571A
Mechanical Data
- Coding (clock hour position) - 6
- Colour code - red
- Connection terminals finely-stranded max. - 2 x 6,00 mm2
- Connection terminals min. - 2.50 mm²
- Connection terminals solid max. - 2 x 10,00 mm2
- Degree of protection (IP) - IP66
- Degree of protection note - according to IEC/EN 60529
- Detailed number of poles - 4 P (3 P + PE)
- Enclosure material - Polyamide, Glass fibre reinforced
- Height - 207.000 mm
- Length - 281.000 mm
- Lockable in - in 0- and I-position
- Series - SolConeX
- Silicone-free - Yes
- Type of connection cable - Finely stranded, solid
- Weight - 2.200 kg
- Width - 135.000 mm
150894
Reliable load disconnect switch with clearly visible, lockable handle which also displays the switching position
Optional auxiliary contacts for control and signalling purposes, pluggable
With AC-3 motor switching capacity according to IEC/EN 60947-3
Ambient Conditions
- Ambient temperature - -30 °C ... +55 °C -30 °C ... +40 °C
- Ambient temperature max. - +55 °C
- Ambient temperature max. note - max. 32 A
- Ambient temperature max. note 2 - max. 32 A
- Ambient temperature max.2 - +40 °C
- Ambient temperature min. - -30 °C
- Ambient temperature min. 2 - -30 °C
Components
- Cable diameter - 9.00 - 21.00 mm
- Cable entry note - positioning on the top or at the side, according to the order
- Entries - 2 x M32
- Material of screw connections - Polyamide, black
- Screw connections - 1 x M32
- Stopping plug - 1 x M32
- Stopping plug material - Polyamide, black
Electrical Data
- Auxiliary contacts available - No
- Frequency range - 50 - 60 Hz
- N-pole present - No
- Optional auxiliary contacts - Yes
- PE-pole present - Yes
- Rated operational current - 32.000 A
- Rated operational current - 0.000 - 32.000 A
- Rated operational voltage AC - 500.00 V
- Rated operational voltage AC - 480.00 - 500.00 V
- Type of voltage - Low voltage
Explosion Protection
- Ambient temperature °C - -30 - 55 °C
- Ambient temperature °C 2 - -30 - 40 °C
- Application range (zones) - 1, 2, 21, 22
- ATEX dust certificate - PTB 04 ATEX 1060
- ATEX gas certificate - PTB 04 ATEX 1060
- Certificate EAC - TS RU S-DE.GB04.B.00282
- Certificates - ATEX (PTB), Brazil (ULB), EAC (STV), IECEx (PTB)
- Dust explosion protection ATEX - II 2 D Ex tb IIIC T75 °C Db
- Dust Explosion Protection ATEX 2 - II 2 D Ex tb IIIC T60 °C Db
- Dust explosion protection EAC - Ex tD A21 IP 66 T60 °C, T75 °C
- Dust explosion protection IECEx - Ex tb IIIC T75 °C Db
- Dust explosion protection IECEx 2 - Ex tb IIIC T60 °C Db
- Gas explosion protection ATEX - II 2 G Ex db eb IIC T5 Gb
- Gas explosion protection ATEX 2 - II 2 G Ex db eb IIC T6 Gb
- Gas explosion protection EAC - 2 Ex de IIC T6/T5 2 Ex de [ia] IIC T6/T5
- Gas explosion protection IECEx - Ex db eb IIC T5 Gb
- Gas explosion protection IECEx 2 - Ex db eb IIC T6 Gb
- IECEX dust certificate - IECEx PTB 05.0024
- IECEX gas certificate - IECEx PTB 05.0024
- Languages of the documentation - English, German
General
- Functional Description - R. STAHL Series 8571/11 SolConeX sockets for Zone 1/21 in a 3-, 4- and 5-pole version have full AC-3 switching capacity up to 32 A. The high degree of protection IP66 guarantees the highest level of protection against the penetration of dust and/or water in any application position. Self-cleaning lamellar contacts provide optimum contact and the plugs can be inserted and removed in the zero position quickly and easily. The load disconnect switch, with mechanical locking device and a handle that can be locked in the 0 or I position, is an additional safety feature.
- Highlights - Reliable load disconnect switch with clearly visible, lockable handle which also displays the switching position Optional auxiliary contacts for control and signalling purposes, pluggable With AC-3 motor switching capacity according to IEC/EN 60947-3
- Product Description - Switch socket
- Product Type - 8571/11-407
- Title Product Variant Technical Data - 8571/11-407 WS 480-500V, 50/60Hz
- WebCode - 8571A
Mechanical Data
- Coding (clock hour position) - 7
- Colour code - black
- Connection terminals finely-stranded max. - 2 x 6,00 mm2
- Connection terminals min. - 2.50 mm²
- Connection terminals solid max. - 2 x 10,00 mm2
- Degree of protection (IP) - IP66
- Degree of protection note - according to IEC/EN 60529
- Detailed number of poles - 4 P (3 P + PE)
- Enclosure material - Polyamide, Glass fibre reinforced
- Height - 207.000 mm
- Length - 281.000 mm
- Lockable in - in 0- and I-position
- Series - SolConeX
- Silicone-free - Yes
- Type of connection cable - Finely stranded, solid
- Weight - 2.200 kg
- Width - 135.000 mm
150898
Reliable load disconnect switch with clearly visible, lockable handle which also displays the switching position
Optional auxiliary contacts for control and signalling purposes, pluggable
With AC-3 motor switching capacity according to IEC/EN 60947-3
Ambient Conditions
- Ambient temperature - -30 °C ... +55 °C -30 °C ... +40 °C
- Ambient temperature max. - +55 °C
- Ambient temperature max. note - max. 32 A
- Ambient temperature max. note 2 - max. 32 A
- Ambient temperature max.2 - +40 °C
- Ambient temperature min. - -30 °C
- Ambient temperature min. 2 - -30 °C
Components
- Cable diameter - 9.00 - 21.00 mm
- Cable entry note - positioning on the top or at the side, according to the order
- Entries - 2 x M32
- Material of screw connections - Polyamide, black
- Screw connections - 1 x M32
- Stopping plug - 1 x M32
- Stopping plug material - Polyamide, black
Electrical Data
- Auxiliary contacts available - No
- Frequency range - 50 - 60 Hz
- N-pole present - No
- Optional auxiliary contacts - Yes
- PE-pole present - Yes
- Rated operational current - 0.000 - 32.000 A
- Rated operational current - 32.000 A
- Rated operational voltage AC - 200.00 - 250.00 V
- Rated operational voltage AC - 250.00 V
- Type of voltage - Low voltage
Explosion Protection
- Ambient temperature °C - -30 - 55 °C
- Ambient temperature °C 2 - -30 - 40 °C
- Application range (zones) - 1, 2, 21, 22
- ATEX dust certificate - PTB 04 ATEX 1060
- ATEX gas certificate - PTB 04 ATEX 1060
- Certificate EAC - TS RU S-DE.GB04.B.00282
- Certificates - ATEX (PTB), Brazil (ULB), EAC (STV), IECEx (PTB)
- Dust explosion protection ATEX - II 2 D Ex tb IIIC T75 °C Db
- Dust Explosion Protection ATEX 2 - II 2 D Ex tb IIIC T60 °C Db
- Dust explosion protection EAC - Ex tD A21 IP 66 T60 °C, T75 °C
- Dust explosion protection IECEx - Ex tb IIIC T75 °C Db
- Dust explosion protection IECEx 2 - Ex tb IIIC T60 °C Db
- Gas explosion protection ATEX - II 2 G Ex db eb IIC T5 Gb
- Gas explosion protection ATEX 2 - II 2 G Ex db eb IIC T6 Gb
- Gas explosion protection EAC - 2 Ex de IIC T6/T5 2 Ex de [ia] IIC T6/T5
- Gas explosion protection IECEx - Ex db eb IIC T5 Gb
- Gas explosion protection IECEx 2 - Ex db eb IIC T6 Gb
- IECEX dust certificate - IECEx PTB 05.0024
- IECEX gas certificate - IECEx PTB 05.0024
- Languages of the documentation - English, German
General
- Functional Description - R. STAHL Series 8571/11 SolConeX sockets for Zone 1/21 in a 3-, 4- and 5-pole version have full AC-3 switching capacity up to 32 A. The high degree of protection IP66 guarantees the highest level of protection against the penetration of dust and/or water in any application position. Self-cleaning lamellar contacts provide optimum contact and the plugs can be inserted and removed in the zero position quickly and easily. The load disconnect switch, with mechanical locking device and a handle that can be locked in the 0 or I position, is an additional safety feature.
- Highlights - Reliable load disconnect switch with clearly visible, lockable handle which also displays the switching position Optional auxiliary contacts for control and signalling purposes, pluggable With AC-3 motor switching capacity according to IEC/EN 60947-3
- Product Description - Switch socket
- Product Type - 8571/11-409
- Title Product Variant Technical Data - 8571/11-409 WS 200-250V, 50/60Hz
- WebCode - 8571A
Mechanical Data
- Coding (clock hour position) - 9
- Colour code - blue
- Connection terminals finely-stranded max. - 2 x 6,00 mm2
- Connection terminals min. - 2.50 mm²
- Connection terminals solid max. - 2 x 10,00 mm2
- Degree of protection (IP) - IP66
- Degree of protection note - according to IEC/EN 60529
- Detailed number of poles - 4 P (3 P + PE)
- Enclosure material - Polyamide, Glass fibre reinforced
- Height - 207.000 mm
- Length - 281.000 mm
- Lockable in - in 0- and I-position
- Series - SolConeX
- Silicone-free - Yes
- Type of connection cable - Finely stranded, solid
- Weight - 2.200 kg
- Width - 135.000 mm
150902
Reliable load disconnect switch with clearly visible, lockable handle which also displays the switching position
Optional auxiliary contacts for control and signalling purposes, pluggable
With AC-3 motor switching capacity according to IEC/EN 60947-3
Ambient Conditions
- Ambient temperature - -30 °C ... +55 °C -30 °C ... +40 °C
- Ambient temperature max. - +55 °C
- Ambient temperature max. note - max. 32 A
- Ambient temperature max. note 2 - max. 32 A
- Ambient temperature max.2 - +40 °C
- Ambient temperature min. - -30 °C
- Ambient temperature min. 2 - -30 °C
Components
- Cable diameter - 9.00 - 21.00 mm
- Cable entry note - positioning on the top or at the side, according to the order
- Entries - 2 x M32
- Material of screw connections - Polyamide, black
- Screw connections - 1 x M32
- Stopping plug - 1 x M32
- Stopping plug material - Polyamide, black
Electrical Data
- Auxiliary contacts available - No
- Frequency range - 50 - 60 Hz
- N-pole present - No
- Optional auxiliary contacts - Yes
- PE-pole present - Yes
- Rated operational current - 0.000 - 32.000 A
- Rated operational voltage AC - 690.00 V
- Type of voltage - Low voltage
Explosion Protection
- Ambient temperature °C - -30 - 55 °C
- Ambient temperature °C 2 - -30 - 40 °C
- Application range (zones) - 1, 2, 21, 22
- ATEX dust certificate - PTB 04 ATEX 1060
- ATEX gas certificate - PTB 04 ATEX 1060
- Certificate EAC - TS RU S-DE.GB04.B.00282
- Certificates - ATEX (PTB), Brazil (ULB), EAC (STV), IECEx (PTB)
- Dust explosion protection ATEX - II 2 D Ex tb IIIC T75 °C Db
- Dust Explosion Protection ATEX 2 - II 2 D Ex tb IIIC T60 °C Db
- Dust explosion protection EAC - Ex tD A21 IP 66 T60 °C, T75 °C
- Dust explosion protection IECEx - Ex tb IIIC T75 °C Db
- Dust explosion protection IECEx 2 - Ex tb IIIC T60 °C Db
- Gas explosion protection ATEX - II 2 G Ex db eb IIC T5 Gb
- Gas explosion protection ATEX 2 - II 2 G Ex db eb IIC T6 Gb
- Gas explosion protection EAC - 2 Ex de IIC T6/T5 2 Ex de [ia] IIC T6/T5
- Gas explosion protection IECEx - Ex db eb IIC T5 Gb
- Gas explosion protection IECEx 2 - Ex db eb IIC T6 Gb
- IECEX dust certificate - IECEx PTB 05.0024
- IECEX gas certificate - IECEx PTB 05.0024
- Languages of the documentation - English, German
General
- Functional Description - R. STAHL Series 8571/11 SolConeX sockets for Zone 1/21 in a 3-, 4- and 5-pole version have full AC-3 switching capacity up to 32 A. The high degree of protection IP66 guarantees the highest level of protection against the penetration of dust and/or water in any application position. Self-cleaning lamellar contacts provide optimum contact and the plugs can be inserted and removed in the zero position quickly and easily. The load disconnect switch, with mechanical locking device and a handle that can be locked in the 0 or I position, is an additional safety feature.
- Highlights - Reliable load disconnect switch with clearly visible, lockable handle which also displays the switching position Optional auxiliary contacts for control and signalling purposes, pluggable With AC-3 motor switching capacity according to IEC/EN 60947-3
- Product Description - Switch socket
- Product Type - 8571/11-405
- Title Product Variant Technical Data - 8571/11-...
- WebCode - 8571A
Mechanical Data
- Coding (clock hour position) - 5
- Colour code - black
- Connection terminals finely-stranded max. - 2 x 6,00 mm2
- Connection terminals min. - 2.50 mm²
- Connection terminals solid max. - 2 x 10,00 mm2
- Degree of protection (IP) - IP66
- Degree of protection note - according to IEC/EN 60529
- Detailed number of poles - 4 P (3 P + PE)
- Enclosure material - Polyamide, Glass fibre reinforced
- Height - 207.000 mm
- Length - 281.000 mm
- Lockable in - in 0- and I-position
- Series - SolConeX
- Silicone-free - Yes
- Type of connection cable - Finely stranded, solid
- Weight - 2.200 kg
- Width - 135.000 mm
150906
Reliable load disconnect switch with clearly visible, lockable handle which also displays the switching position
Optional auxiliary contacts for control and signalling purposes, pluggable
With AC-3 motor switching capacity according to IEC/EN 60947-3
Ambient Conditions
- Ambient temperature - -30 °C ... +40 °C
- Ambient temperature max. - +40 °C
- Ambient temperature min. - -30 °C
Components
- Cable diameter - 9.00 - 21.00 mm
- Cable entry note - positioning on the top or at the side, according to the order
- Entries - 2 x M32
- Screw connections - 1 x M32
- Stopping plug - 1 x M32
- Stopping plug material - Polyamide, black
Electrical Data
- Auxiliary contacts available - No
- Frequency range - 100 - 300 Hz
- N-pole present - No
- Optional auxiliary contacts - Yes
- PE-pole present - Yes
- Rated operational current - 0.000 - 25.000 A
- Rated operational voltage AC - 51.00 - 690.00 V
- Type of voltage - Low voltage
Explosion Protection
- Ambient temperature °C - -30 - 40 °C
- Application range (zones) - 1, 2, 21, 22
- ATEX dust certificate - PTB 04 ATEX 1060
- ATEX gas certificate - PTB 04 ATEX 1060
- Certificate EAC - TS RU S-DE.GB04.B.00282
- Certificates - ATEX (PTB), Brazil (ULB), EAC (STV), IECEx (PTB)
- Dust explosion protection ATEX - II 2 D Ex tb IIIC T75 °C Db
- Dust Explosion Protection ATEX 2 - II 2 D Ex tb IIIC T60 °C Db
- Dust explosion protection EAC - Ex tD A21 IP 66 T60 °C, T75 °C
- Dust explosion protection IECEx - Ex tb IIIC T75 °C Db
- Dust explosion protection IECEx 2 - Ex tb IIIC T60 °C Db
- Gas explosion protection ATEX - II 2 G Ex db eb IIC T5 Gb
- Gas explosion protection ATEX 2 - II 2 G Ex db eb IIC T6 Gb
- Gas explosion protection EAC - 2 Ex de IIC T6/T5 2 Ex de [ia] IIC T6/T5
- Gas explosion protection IECEx - Ex db eb IIC T5 Gb
- Gas explosion protection IECEx 2 - Ex db eb IIC T6 Gb
- IECEX dust certificate - IECEx PTB 05.0024
- IECEX gas certificate - IECEx PTB 05.0024
- Languages of the documentation - English, German
General
- Functional Description - R. STAHL Series 8571/11 SolConeX sockets for Zone 1/21 in a 3-, 4- and 5-pole version have full AC-3 switching capacity up to 32 A. The high degree of protection IP66 guarantees the highest level of protection against the penetration of dust and/or water in any application position. Self-cleaning lamellar contacts provide optimum contact and the plugs can be inserted and removed in the zero position quickly and easily. The load disconnect switch, with mechanical locking device and a handle that can be locked in the 0 or I position, is an additional safety feature.
- Highlights - Reliable load disconnect switch with clearly visible, lockable handle which also displays the switching position Optional auxiliary contacts for control and signalling purposes, pluggable With AC-3 motor switching capacity according to IEC/EN 60947-3
- Product Description - Switch socket
- Product Type - 8571/11-410
- WebCode - 8571A
Mechanical Data
- Coding (clock hour position) - 10
- Colour code - green
- Connection terminals finely-stranded max. - 2 x 6,00 mm2
- Connection terminals min. - 2.50 mm²
- Connection terminals solid max. - 2 x 10,00 mm2
- Degree of protection (IP) - IP66
- Degree of protection note - according to IEC/EN 60529
- Detailed number of poles - 4 P (3 P + PE)
- Enclosure material - Polyamide, Glass fibre reinforced
- Height - 207.000 mm
- Length - 281.000 mm
- Lockable in - in 0- and I-position
- Series - SolConeX
- Silicone-free - Yes
- Type of connection cable - Finely stranded, solid
- Weight - 2.200 kg
- Width - 135.000 mm
150910
Reliable load disconnect switch with clearly visible, lockable handle which also displays the switching position
Optional auxiliary contacts for control and signalling purposes, pluggable
With AC-3 motor switching capacity according to IEC/EN 60947-3
Ambient Conditions
- Ambient temperature - -30 °C ... +55 °C -30 °C ... +40 °C
- Ambient temperature max. - +55 °C
- Ambient temperature max. note - max. 32 A
- Ambient temperature max. note 2 - max. 32 A
- Ambient temperature max.2 - +40 °C
- Ambient temperature min. - -30 °C
- Ambient temperature min. 2 - -30 °C
Components
- Cable diameter - 9.00 - 21.00 mm
- Cable entry note - positioning on the top or at the side, according to the order
- Entries - 2 x M32
- Material of screw connections - Polyamide, black
- Screw connections - 1 x M32
- Stopping plug - 1 x M32
- Stopping plug material - Polyamide, black
Electrical Data
- Auxiliary contacts available - No
- Frequency range - 60 - 60 Hz
- N-pole present - No
- Optional auxiliary contacts - Yes
- PE-pole present - Yes
- Rated operational current - 0.000 - 32.000 A
- Rated operational current - 32.000 A
- Rated operational voltage AC - 460.00 V
- Rated operational voltage AC - 440.00 - 460.00 V
- Type of voltage - Low voltage
Explosion Protection
- Ambient temperature °C - -30 - 55 °C
- Ambient temperature °C 2 - -30 - 40 °C
- Application range (zones) - 1, 2, 21, 22
- ATEX dust certificate - PTB 04 ATEX 1060
- ATEX gas certificate - PTB 04 ATEX 1060
- Certificate EAC - TS RU S-DE.GB04.B.00282
- Certificates - ATEX (PTB), Brazil (ULB), EAC (STV), IECEx (PTB)
- Dust explosion protection ATEX - II 2 D Ex tb IIIC T75 °C Db
- Dust Explosion Protection ATEX 2 - II 2 D Ex tb IIIC T60 °C Db
- Dust explosion protection EAC - Ex tD A21 IP 66 T60 °C, T75 °C
- Dust explosion protection IECEx - Ex tb IIIC T75 °C Db
- Dust explosion protection IECEx 2 - Ex tb IIIC T60 °C Db
- Gas explosion protection ATEX - II 2 G Ex db eb IIC T5 Gb
- Gas explosion protection ATEX 2 - II 2 G Ex db eb IIC T6 Gb
- Gas explosion protection EAC - 2 Ex de IIC T6/T5 2 Ex de [ia] IIC T6/T5
- Gas explosion protection IECEx - Ex db eb IIC T5 Gb
- Gas explosion protection IECEx 2 - Ex db eb IIC T6 Gb
- IECEX dust certificate - IECEx PTB 05.0024
- IECEX gas certificate - IECEx PTB 05.0024
- Languages of the documentation - English, German
General
- Functional Description - R. STAHL Series 8571/11 SolConeX sockets for Zone 1/21 in a 3-, 4- and 5-pole version have full AC-3 switching capacity up to 32 A. The high degree of protection IP66 guarantees the highest level of protection against the penetration of dust and/or water in any application position. Self-cleaning lamellar contacts provide optimum contact and the plugs can be inserted and removed in the zero position quickly and easily. The load disconnect switch, with mechanical locking device and a handle that can be locked in the 0 or I position, is an additional safety feature.
- Highlights - Reliable load disconnect switch with clearly visible, lockable handle which also displays the switching position Optional auxiliary contacts for control and signalling purposes, pluggable With AC-3 motor switching capacity according to IEC/EN 60947-3
- Product Description - Switch socket
- Product Type - 8571/11-411
- Title Product Variant Technical Data - 8571/11-411 WS 440-460V, 60Hz
- WebCode - 8571A
Mechanical Data
- Coding (clock hour position) - 11
- Colour code - red
- Connection terminals finely-stranded max. - 2 x 6,00 mm2
- Connection terminals min. - 2.50 mm²
- Connection terminals solid max. - 2 x 10,00 mm2
- Degree of protection (IP) - IP66
- Degree of protection note - according to IEC/EN 60529
- Detailed number of poles - 4 P (3 P + PE)
- Enclosure material - Polyamide, Glass fibre reinforced
- Height - 207.000 mm
- Length - 281.000 mm
- Lockable in - in 0- and I-position
- Series - SolConeX
- Silicone-free - Yes
- Type of connection cable - Finely stranded, solid
- Weight - 2.200 kg
- Width - 135.000 mm
166610
Reliable load disconnect switch with clearly visible, lockable handle which also displays the switching position
Optional auxiliary contacts for control and signalling purposes, pluggable
With AC-3 motor switching capacity according to IEC/EN 60947-3
Ambient Conditions
- Ambient temperature - -30 °C ... +55 °C -30 °C ... +40 °C
- Ambient temperature max. - +55 °C
- Ambient temperature max.2 - +40 °C
- Ambient temperature min. - -30 °C
- Ambient temperature min. 2 - -30 °C
Components
- Cable diameter - 9.00 - 21.00 mm
- Cable diameter 2 - 7.00 - 17.00 mm
- Cable entry accessories - With plug
- Cable entry note - positioning on the top or at the side, according to the order
- Entries - 1 x M25 1 x M32
- Material of cable entry 2 - Polyamide, blue
- Material of screw connections - Polyamide, black
- Screw connections - 1 x M25, 1 x M32
Electrical Data
- Auxiliary contacts available - Yes
- Frequency range - 50 - 60 Hz
- N-pole present - No
- Optional auxiliary contacts - Yes
- PE-pole present - Yes
- Rated operational current - 0.000 - 32.000 A
- Rated operational current - 32.000 A
- Rated operational voltage AC - 500.00 V
- Rated operational voltage AC - 480.00 - 500.00 V
- Type of voltage - Low voltage
Explosion Protection
- Ambient temperature °C - -30 - 55 °C
- Ambient temperature °C 2 - -30 - 40 °C
- Application range (zones) - 1, 2, 21, 22
- ATEX dust certificate - PTB 04 ATEX 1060
- ATEX gas certificate - PTB 04 ATEX 1060
- Certificate EAC - TS RU S-DE.GB04.B.00282
- Certificates - ATEX (PTB), Brazil (ULB), EAC (STV), IECEx (PTB)
- Dust explosion protection ATEX - II 2 D Ex tb IIIC T75 °C Db
- Dust Explosion Protection ATEX 2 - II 2 D Ex tb IIIC T60 °C Db
- Dust explosion protection EAC - Ex tD A21 IP 66 T60 °C, T75 °C
- Dust explosion protection IECEx - Ex tb IIIC T75 °C Db
- Dust explosion protection IECEx 2 - Ex tb IIIC T60 °C Db
- Gas explosion protection ATEX - II 2 G Ex db eb IIC T5 Gb
- Gas explosion protection ATEX 2 - II 2 G Ex db eb IIC T6 Gb
- Gas explosion protection EAC - 2 Ex de IIC T6/T5 2 Ex de [ia] IIC T6/T5
- Gas explosion protection IECEx - Ex db eb IIC T5 Gb
- Gas explosion protection IECEx 2 - Ex db eb IIC T6 Gb
- IECEX dust certificate - IECEx PTB 05.0024
- IECEX gas certificate - IECEx PTB 05.0024
- Languages of the documentation - English, German
General
- Functional Description - R. STAHL Series 8571/11 SolConeX sockets for Zone 1/21 in a 3-, 4- and 5-pole version have full AC-3 switching capacity up to 32 A. The high degree of protection IP66 guarantees the highest level of protection against the penetration of dust and/or water in any application position. Self-cleaning lamellar contacts provide optimum contact and the plugs can be inserted and removed in the zero position quickly and easily. The load disconnect switch, with mechanical locking device and a handle that can be locked in the 0 or I position, is an additional safety feature.
- Highlights - Reliable load disconnect switch with clearly visible, lockable handle which also displays the switching position Optional auxiliary contacts for control and signalling purposes, pluggable With AC-3 motor switching capacity according to IEC/EN 60947-3
- Product Description - Switch socket
- Product Type - 8571/11-407-S001
- Title Product Variant Technical Data - 8571/11-407-S001 WS 480-500V, 50/60Hz
- WebCode - 8571A
Mechanical Data
- Coding (clock hour position) - 7
- Colour code - black
- Connection terminals finely-stranded max. - 2 x 6,00 mm2
- Connection terminals min. - 2.50 mm²
- Connection terminals solid max. - 2 x 10,00 mm2
- Degree of protection (IP) - IP66
- Degree of protection note - according to IEC/EN 60529
- Detailed number of poles - 4 P (3 P + PE)
- Enclosure material - Polyamide, Glass fibre reinforced
- Height - 207.000 mm
- Length - 281.000 mm
- Lockable in - in 0- and I-position
- Series - SolConeX
- Silicone-free - Yes
- Type of connection cable - Finely stranded, solid
- Weight - 2.200 kg
- Width - 135.000 mm
1 - 12 of 20 Part Numbers