Yodify Product Library
Instantly add the 8220 Conductivity Sensor and 50,000+ more product series to your store or catalog  
Book Your Demo and See How
or create your store

The conductivity sensor is a compact probe with integrated conductivity electrodes. Four conductivity probes having different cell constants are available and offer a large measurement range. 

The Pt1000 for automatic temperature compensation is integrated in the sensor housing. The sensor transmits directly a raw signal and is fitted with a standard EN 175301-803 plug connector. 

The sensor has to be connected to the Burkert conductivity transmitter Type 8225 for panel or wall mounting or to the multiCELL transmitter/ controller Type 8619 via a shielded cable (maximal cable length of 10 meters).
Features
  • Compact version for DN15 to DN200
  • Large capabilities of conductivity measurement through different cells
  • Large range of process connections with various fittings

1 - 4 of 4 Part Numbers
426 872
426 872
  • Measuring Range / Cell Constant - 0.05 to 20 µS/cm / C = 0.01
426 873
426 873
  • Measuring Range / Cell Constant - 0.5 to 200 µS/cm / C = 0.1
426 874
426 874
  • Measuring Range / Cell Constant - 5 µS/cm to 10 mS/cm / C = 1
426 875
426 875
  • Measuring Range / Cell Constant - 0.5 to 200 mS/cm / C = 10
1 - 4 of 4 Part Numbers

Specifications

Ambient Temperature Range

  • Operation & Storage: 0° to 60° C (32° to 140° F)

Approvals & Certifications

  • CE
  • EU Directives
  • PED 2014/68/EU

Cable Length

  • 32.8 feet (10 metres)

Compensated Temperature

  • Temperature Measurement: Automatic (Integrated Pt1000) - Reference Temperature 25° C (77° F)

Current

  • 4-20 mA

Diameter

  • Pipe: 0.59 to 7.8” (15 to 200 mm)

Electrical Connectors

  • 4 x 0.2 to 1.5 mm² Shielded
  • Cable Plug EN 175301-803

Enclosure, Body Material

  • Polycarbonate (PC)

Environmental Protection

  • IP65

Humidity

  • ≤ 80 % Relative Humidity, Non-Condensing

Materials of Construction

  • Electrode: Stainless Steel for Cell Constant C= 0.01 or 0.1
  • Graphite for Cell Constant C= 1.0 or 10

Measuring Error

  • Conductivity Measurement Deviation - Typical: 3 to 5 % of Measured Value
  • Temperature Measurement Deviation: ± 1° C (1.8° F)

Measuring Range

  • Conductivity Measurement: 0.05 to 200,000 µS/cm

Media

  • Water

Pipe Connection

  • DN 100 Pipe
  • DN 15 Pipe
  • DN 20 Pipe
  • DN 25 Pipe
  • DN 32 Pipe
  • DN 40 Pipe
  • DN 50 Pipe
  • DN 65 Pipe
  • DN 80 Pipe

Plug Material

  • Cable Plug: Polyamide (PA)

Pressure Range

  • psi: 0 to 145 (kPa: 0 to 1,000, bar: 0 to 10) - Max.

Process Temperature

  • PP: 0° to 80° C (32° to 176° F)
  • PVC: 0° to 50° C (32° to 122° F)
  • PVDF, Stainless Steel, Brass: 0° to 100° C (32° to 212° F)

Resolution

  • Temperature Measurement: 0.1° C

RTD Type

  • Pt1000

Screw Material

  • Stainless Steel

Seat / Seal Material

  • Seal: EPDM
  • Seal: FKM

Sensor, Probe Material

  • Pt1000: 316Ti Stainless Steel 1.4571

Temperature Range

  • Measuring Range: -50° to 150° C (-58° to 302° F)

Welded Connection

  • DN 100 Weld End
  • DN 125 Weld End
  • DN 150 Weld End
  • DN 200 Weld End
  • DN 50 Weld End
  • DN 65 Weld End
  • DN 80 Weld End

Wetted Materials

  • Fitting, Sensor Holder: PVDF
  • Fitting: 316L Stainless Steel, 1.4404
  • Fitting: Brass
  • Fitting: Polypropylene (PP)
  • Fitting: PVC

Instantly populate your store or catalog 
CREATE YOUR SITE
or book a demo with the Yodify Team
show more