The FP1P is a compact, front terminal connection type pulse repeater that converts pulses from voltage-free contacts, open collector contacts, voltage, and current into isolated transistor switch pulses.
Features
  • With built-in 12 V or 24 V power supply for transmitter inputs
  • Internal filter can be set to eliminate chattering. (In cases where the input frequency range is up to 100 Hz, the pulse width is 3 ms or more)

Specifications

Consumption

  • 60 mA at 24 Vdc

Electrical Connectors

  • M4 Screw Terminal

Electrical Rating

  • 15 mA - Max.
  • 30 mA - Max.

Enclosure, Body Material

  • ABS Resin

Frequency

  • 0 to 10,000 Hz - Input Frequency in Case the Input is Voltage Pulse & the Swing is 5 V or more
  • 0 to 6,000 Hz - Input, Output Frequency

Humidity

  • 5 to 90 % Relative Humidity Non-Condensing - Operating Humidity Range

Input

  • Relay Contact
  • Transistor ON/OFF Contact

Input Signal

  • 2-Wire - Voltage-Free Contact Pulse, Voltage Pulse, or Current Pulse
  • 3-Wire - Voltage Pulse or Current Pulse

Insulation Resistance

  • 100 megaohms or more at 500 Vdc between Input & Output, Output & Power Supply & Input & Power Supply

Mounting

  • DIN Rail Mounting
  • Rack-Mounted
  • Wall Mounted

Operating Temperature

  • 0° to 50° C (32° to 122° F)

Output Format

  • Transistor Output (Open Collector)

Power Supply

  • 12 Vdc ± 10 %
  • 24 Vdc ± 10 % (Percentage Ripple is 5 % Peak-to-Peak or Less)
  • 30 mA or Less

Power Supply Effect

  • ± 0.1 % of Span or Less for the Fluctuations within the Operating Range of Power Supply Voltage Specification

Pulse Range

  • 60 µs - Min. Input Pulse Width ON, OFF

Resistance

  • 1 Kiloohm - Internal Load Resistance (For Current Pulse)
  • 100 kiloohms or more - Contact Resistance Open
  • 15 kiloohms or more for Contact or Voltage Pulse - Input Resistance
  • 200 ohms - Internal Load Resistance (For Current Pulse), or Less for Contact Resistance Close
  • 510 ohms - Internal Load Resistance (For Current Pulse)

Supply Voltage

  • -1 to 8 Vdc - Low Level
  • 1,500 Vac/minute between Input & (Output & Power Supply) - Withstand Voltage
  • 3-24 Vdc - High Level
  • 500 Vac/minute between Output & Power Supply - Withstand Voltage