Yodify Product Library
Instantly add the FHM10 Fume Hood Monitor and 50,000+ more product series to your store or catalog  
Book Your Demo and See How
or create your store

FHM10 Fume Hood Monitor

Brand: TSI Incorporated

Fume hoods are a primary source or protection in laboratories. Face velocity measurements are often used to gauge the performance of a fume hood’s ability to contain and exhaust hazardous chemicals. 

By accurately measuring face velocity and alarming on unsafe conditions, TSI’s FHM10 Fume Hood Monitors provide a high level of fume hood safety. And, the FHM10 helps users comply with standards and regulations set forth by OSHA, NFPA, ANSI Z9.5, and SEFA, calling for monitors to be installed on fume hoods.
Features
  • Accurately measures average fume hood face velocity
  • Temperature compensated sensor for accurate measurement as temperatures change in laboratories
  • Visual, audible, and remote alarms warn users of unsafe conditions
  • Analog output provides additional information
  • Assists in managing risk by communicating fume hood status information to Building Management System (BMS)
  • Seamless integration to BMS via BACnet®, LonWorks®, or Modbus®
  • Easy installation and calibration
  • Easy configuration using keypad
  • Large display provides detailed fume hood information
  • Surface or flush mount options available
  • Optional Flow Monitor available

1 - 2 of 2 Part Numbers
FHM10-01
FHM10-01
TSI Fume Hood Monitors
TSI’s Sidewall Velocity Sensor 
Visual and Audible Alarms 
Contact Inputs 
Analog Outputs 
Alarm Contact Outputs 
RS-485 (Modbus, Johnson N2) 
BACnet MS/TP or LonWorks Compatible Optional
FHM10-02
FHM10-02
TSI Fume Hood Monitors
Visual and Audible Alarms
Flow Input 
Contact Inputs 
Analog Outputs 
Alarm Contact Outputs 
RS-485 (Modbus, Johnson N2) 
BACnet MS/TP or LonWorks Compatible Optional
1 - 2 of 2 Part Numbers

Specifications

Display Range

  • 0 to 1,000 fpm (0 to 5.08 m/s)
  • 0 to 10,000 cfm (0 to 4,720 l/s, 0 to 16,990 m³/hr)

Alarm Range

  • Low: 5 to 960 fpm (0.03 to 4.88 m/s), 0 to 10,000 cfm (0 to 4,720 l/s, 0 to 16,990 m³/hr)
  • High: 80 to 1,000 fpm (0.41 to 5.08 m/s), 0 to 10,000 cfm (0 to 4,720 l/s, 0 to 16,990 m³/hr)

Output

  • Analog: 0-10 Vdc or 4-20 mA, Represents Face Velocity, or Flow Rate
  • Alarm Contact Output: SPST, 2 A @ 30 Vdc Nominal

Contact Input

  • Night Setback, Flow

Communication

  • Modbus, N2, BACnet MS/TP, LonWorks

Power Input

  • 24 Vac, 50/60 Hz or 15-40 Vdc, 5 W Max.

Operating Temperature

  • 32° to 120° F (0° to 48.9° C)

Dimensions (H x W x D)

  • 6.67” x 2.92” x 1.25” (16.9 cm x 7.4 cm x 3.2 cm)

Weight

  • 0.5 lb (225 g)

  • Research laboratories
  • Life Science and Pharmaceutical
  • Universities and Academic
  • Vivariums
  • Healthcare Facilities
Instantly populate your store or catalog 
CREATE YOUR SITE
or book a demo with the Yodify Team
show more