Temperature Transmitter Series 9182
Brand: R. STAHL AG9182 series Ex i temperature transmitters for field circuits can be used to connect temperature sensors and potentiometers.
They are easy to configure for virtually any sensor type by means of software or a DIP switch.
These sensor types include Pt100 sensors, thermocouples and potentiometers.
Variants with a trip amplifier function allow the input signal to be analyzed using two independent contacts.
Features- Ex i temperature transmitter, can be configured for virtually any common sensor type
- broad range, including variants with signal conversion and trip amplifier function
- can be used up to SIL 2 (IEC/EN 61508)
1 - 12 of 12 Part Numbers
160541
Ex i temperature transmitter, can be configured for virtually any common sensor type
broad range, including variants with signal conversion and trip amplifier function
can be used up to SIL 2 (IEC/EN 61508)
Ambient Conditions
- Ambient temperature - -20 °C ... +70 °C (Single device) -20 °C ... +60 °C (Group assembly)
- Ambient temperature max. - +70 °C
- Ambient temperature max. note - Single device
- Ambient temperature max. note 2 - Group assembly
- Ambient temperature max.2 - +60 °C
- Ambient temperature min. - -20 °C
- Ambient temperature min. 2 - -20 °C
- Ambient temperature min. note - Single device
- Ambient temperature min. note 2 - Group assembly
- Electromagnetic compatibility - Tested to the following standards and regulations: EN 61326-1 Use in industrial environment; NAMUR NE 21
- Relative humidity max. - 95%
- Storage temperature - -40 °C ... +80 °C
- Storage temperature max. - +80 °C
- Storage temperature min. - -40 °C
- Use at the height of - < 2000 m
Auxiliary power
- Auxiliary power - 24 V DC
- Auxiliary power voltage range - 18 - 31,2 V
- Nominal current - 80.00 mA
- Nominal voltage - 24 V DC
- Polarity reversal protection - yes
- Power consumption - 1.90 W
- Voltage range residual ripple - ≤ 3,6 VSS
Electrical Data
- Input potentiometer - up to 100 kΩ
- Input resistance temperature detector (RTD) - Types Pt 100, Pt 500, Pt 1000, Ni 100, Ni 500, Ni 1000
- Input resistance temperature detector (RTD) Type of circuit - 2-, 3-, 4-wire circuit
- Input thermocouple - Types B, E, J, K, N, R, S, T, L, U, XK
- Number of channels - 2
Explosion Protection
- Application range (zones) - 2, 22
- ATEX dust certificate - DMT 02 ATEX E 243 X
- ATEX gas certificate - DMT 02 ATEX E 243 X
- Certificate EAC - TS RU S-DE.GB04.B.00353
- Certificates - ATEX (BVS), Brazil (ULB), Canada (FM), EAC (STV), IECEx (BVS), India (PESO), Korea (KTL), Russia (Meteorological certificate), SIL (exida), USA (FM), USA (UL)
- Dust explosion protection ATEX - II (1) D [Ex ia Da] IIIC
- Dust explosion protection EAC - [Ex ia Da] IIIC
- Dust explosion protection IECEx - [Ex ia Da] IIIC
- Ex interface in Division NEC 500 - (Class I, II, III) 1, 2
- Ex interface zone - 0, 1, 2, 20, 21, 22
- Gas explosion protection ATEX - II 3 (1) G Ex nA nC [ia Ga] IIC T4 Gc
- Gas explosion protection EAC - 2 Ex nA nC [ia Ga] IIC T4 Gc X
- Gas explosion protection IECEx - Ex nA nC [ia Ga] IIC T4 Gc
- IECEX dust certificate - IECEx BVS 09.0046 X
- IECEX gas certificate - IECEx BVS 09.0046 X
- Installation in Division NEC 500 - (Class I, II, III) 2
- Ship approval - CCS, DNVGL
General
- Functional Description - 9182 series Ex i temperature transmitters for field circuits can be used to connect temperature sensors and potentiometers. They are easy to configure for virtually any sensor type by means of software or a DIP switch. These sensor types include Pt100 sensors, thermocouples and potentiometers. Variants with a trip amplifier function allow the input signal to be analysed using two independent contacts.
- Highlights - Ex i temperature transmitter, can be configured for virtually any common sensor type broad range, including variants with signal conversion and trip amplifier function can be used up to SIL 2 (IEC/EN 61508)
- Product Description - Temperature transmitter Ex i field circuit ISpac
- Product Type - 9182/20-51-11s
- Title Product Variant Technical Data - 9182/20-51-11s temperature transmitter
- WebCode - 9182A
Input
- Input for resistance temperature detector - See table
- Message of line fault and Auxilliary power failure - - Contact (30 V / 100 mA) closed to ground in case of fault - pac-Bus, floating contact (30 V / 100 mA)
Mechanical Data
- Connection cross-section - 0.2-2.5 mm² flexible 0.2-2.5 mm² rigid 0.25-2.5 mm² flexible core end sleeve
- Degree of protection (IP) - IP30
- Enclosure material - Polyamide
- Fire resistance (UL 94) - V0
- Grid dimension - 17.60 mm
- Terminal degree of protection (IP) - IP20
- Weight - 0.195 kg
Mounting / Installation
- Connection type - Screw terminal
- Mounting position - horizontal vertical
- Mounting type - DIN rail (NS35/15, NS35/7.5)
Output
- LFD relay - Yes
- Limit contact (per channel) - without
- Load resistance R L max. - 600.00 Ω
- Output - 0/4 ... 20 mA active / source
- Output functional range - 0.0 - 21.0 mA
- output signal - 0/4 - 20 mA (configurable)
- Response time output - ≤ 500 ms
- Settling time output - ≤ 35 ms
- Switching capacity fault message contact - 30 V / 100 mA
Safety Data
- Internal capacitance C i - negligible
- Internal inductance L i - negligible
- Max. Current I o - 19.7 mA
- Max. Power P o - 32.000 mW
- Max. Voltage U o - 6.50 V
- Safety-related maximum voltage - 253 V
160544
Ex i temperature transmitter, can be configured for virtually any common sensor type
broad range, including variants with signal conversion and trip amplifier function
can be used up to SIL 2 (IEC/EN 61508)
Ambient Conditions
- Ambient temperature - -20 °C ... +70 °C (Single device) -20 °C ... +60 °C (Group assembly)
- Ambient temperature max. - +70 °C
- Ambient temperature max. note - Single device
- Ambient temperature max. note 2 - Group assembly
- Ambient temperature max.2 - +60 °C
- Ambient temperature min. - -20 °C
- Ambient temperature min. 2 - -20 °C
- Ambient temperature min. note - Single device
- Ambient temperature min. note 2 - Group assembly
- Electromagnetic compatibility - Tested to the following standards and regulations: EN 61326-1 Use in industrial environment; NAMUR NE 21
- Relative humidity max. - 95%
- Storage temperature - -40 °C ... +80 °C
- Storage temperature max. - +80 °C
- Storage temperature min. - -40 °C
- Use at the height of - < 2000 m
Auxiliary power
- Auxiliary power - 24 V DC
- Auxiliary power voltage range - 18 - 31,2 V
- Nominal current - 80.00 mA
- Nominal voltage - 24 V DC
- Polarity reversal protection - yes
- Power consumption - 1.90 W
- Voltage range residual ripple - ≤ 3,6 VSS
Electrical Data
- Input potentiometer - up to 100 kΩ
- Input resistance temperature detector (RTD) - Types Pt 100, Pt 500, Pt 1000, Ni 100, Ni 500, Ni 1000
- Input resistance temperature detector (RTD) Type of circuit - 2-, 3-, 4-wire circuit
- Input thermocouple - Types B, E, J, K, N, R, S, T, L, U, XK
- Number of channels - 2
Explosion Protection
- Application range (zones) - 2, 22
- ATEX dust certificate - DMT 02 ATEX E 243 X
- ATEX gas certificate - DMT 02 ATEX E 243 X
- Certificate EAC - TS RU S-DE.GB04.B.00353
- Certificates - ATEX (BVS), Brazil (ULB), Canada (FM), EAC (STV), IECEx (BVS), India (PESO), Korea (KTL), Russia (Meteorological certificate), SIL (exida), USA (FM), USA (UL)
- Dust explosion protection ATEX - II (1) D [Ex ia Da] IIIC
- Dust explosion protection EAC - [Ex ia Da] IIIC
- Dust explosion protection IECEx - [Ex ia Da] IIIC
- Ex interface in Division NEC 500 - (Class I, II, III) 1, 2
- Ex interface zone - 0, 1, 2, 20, 21, 22
- Gas explosion protection ATEX - II 3 (1) G Ex nA nC [ia Ga] IIC T4 Gc
- Gas explosion protection EAC - 2 Ex nA nC [ia Ga] IIC T4 Gc X
- Gas explosion protection IECEx - Ex nA nC [ia Ga] IIC T4 Gc
- IECEX dust certificate - IECEx BVS 09.0046 X
- IECEX gas certificate - IECEx BVS 09.0046 X
- Installation in Division NEC 500 - (Class I, II, III) 2
- Ship approval - CCS, DNVGL
General
- Functional Description - 9182 series Ex i temperature transmitters for field circuits can be used to connect temperature sensors and potentiometers. They are easy to configure for virtually any sensor type by means of software or a DIP switch. These sensor types include Pt100 sensors, thermocouples and potentiometers. Variants with a trip amplifier function allow the input signal to be analysed using two independent contacts.
- Highlights - Ex i temperature transmitter, can be configured for virtually any common sensor type broad range, including variants with signal conversion and trip amplifier function can be used up to SIL 2 (IEC/EN 61508)
- Product Description - Temperature transmitter Ex i field circuit ISpac
- Product Type - 9182/20-51-11k
- Title Product Variant Technical Data - 9182/20-51-11k temperature transmitter
- WebCode - 9182A
Input
- Input for resistance temperature detector - See table
- Message of line fault and Auxilliary power failure - - Contact (30 V / 100 mA) closed to ground in case of fault - pac-Bus, floating contact (30 V / 100 mA)
Mechanical Data
- Degree of protection (IP) - IP30
- Enclosure material - Polyamide
- Fire resistance (UL 94) - V0
- Grid dimension - 17.60 mm
- Terminal degree of protection (IP) - IP20
- Weight - 0.195 kg
Mounting / Installation
- Connection type - Spring clamp terminal
- Mounting position - horizontal vertical
- Mounting type - NS35/15, NS35/7.5 DIN rail
Output
- LFD relay - Yes
- Limit contact (per channel) - without
- Load resistance R L max. - 600.00 Ω
- Output - 0/4 ... 20 mA active / source
- Output functional range - 0.0 - 21.0 mA
- output signal - 0/4 - 20 mA (configurable)
- Response time output - ≤ 500 ms
- Settling time output - ≤ 35 ms
- Switching capacity fault message contact - 30 V / 100 mA
Safety Data
- Internal capacitance C i - negligible
- Internal inductance L i - negligible
- Max. Current I o - 19.7 mA
- Max. Power P o - 32.000 mW
- Max. Voltage U o - 6.50 V
- Safety-related maximum voltage - 253 V
160546
Ex i temperature transmitter, can be configured for virtually any common sensor type
broad range, including variants with signal conversion and trip amplifier function
can be used up to SIL 2 (IEC/EN 61508)
Ambient Conditions
- Ambient temperature - -20 °C ... +70 °C (Single device) -20 °C ... +60 °C (Group assembly)
- Ambient temperature max. - +70 °C
- Ambient temperature max. note - Single device
- Ambient temperature max. note 2 - Group assembly
- Ambient temperature max.2 - +60 °C
- Ambient temperature min. - -20 °C
- Ambient temperature min. 2 - -20 °C
- Ambient temperature min. note - Single device
- Ambient temperature min. note 2 - Group assembly
- Electromagnetic compatibility - Tested to the following standards and regulations: EN 61326-1 Use in industrial environment; NAMUR NE 21
- Relative humidity max. - 95%
- Storage temperature - -40 °C ... +80 °C
- Storage temperature max. - +80 °C
- Storage temperature min. - -40 °C
- Use at the height of - < 2000 m
Auxiliary power
- Auxiliary power - 24 V DC
- Auxiliary power voltage range - 18 - 31,2 V
- Nominal current - 70.00 mA
- Nominal voltage - 24 V DC
- Polarity reversal protection - yes
- Power consumption - 1.90 W
- Voltage range residual ripple - ≤ 3,6 VSS
Electrical Data
- Input potentiometer - up to 100 kΩ
- Input resistance temperature detector (RTD) - Types Pt 100, Pt 500, Pt 1000, Ni 100, Ni 500, Ni 1000
- Input resistance temperature detector (RTD) Type of circuit - 2-, 3-, 4-wire circuit
- Input thermocouple - Types B, E, J, K, N, R, S, T, L, U, XK
- Number of channels - 1
Explosion Protection
- Application range (zones) - 2, 22
- ATEX dust certificate - DMT 02 ATEX E 243 X
- ATEX gas certificate - DMT 02 ATEX E 243 X
- Certificate EAC - TS RU S-DE.GB04.B.00353
- Certificates - ATEX (BVS), Brazil (ULB), Canada (FM), EAC (STV), IECEx (BVS), India (PESO), Korea (KTL), Russia (Meteorological certificate), SIL (exida), USA (FM), USA (UL)
- Dust explosion protection ATEX - II (1) D [Ex ia Da] IIIC
- Dust explosion protection EAC - [Ex ia Da] IIIC
- Dust explosion protection IECEx - [Ex ia Da] IIIC
- Ex interface in Division NEC 500 - (Class I, II, III) 1, 2
- Ex interface zone - 0, 1, 2, 20, 21, 22
- Gas explosion protection ATEX - II 3 (1) G Ex nA nC [ia Ga] IIC T4 Gc
- Gas explosion protection EAC - 2 Ex nA nC [ia Ga] IIC T4 Gc X
- Gas explosion protection IECEx - Ex nA nC [ia Ga] IIC T4 Gc
- IECEX dust certificate - IECEx BVS 09.0046 X
- IECEX gas certificate - IECEx BVS 09.0046 X
- Installation in Division NEC 500 - (Class I, II, III) 2
- Ship approval - CCS, DNVGL
General
- Functional Description - 9182 series Ex i temperature transmitters for field circuits can be used to connect temperature sensors and potentiometers. They are easy to configure for virtually any sensor type by means of software or a DIP switch. These sensor types include Pt100 sensors, thermocouples and potentiometers. Variants with a trip amplifier function allow the input signal to be analysed using two independent contacts.
- Highlights - Ex i temperature transmitter, can be configured for virtually any common sensor type broad range, including variants with signal conversion and trip amplifier function can be used up to SIL 2 (IEC/EN 61508)
- Product Description - Temperature transmitter Ex i field circuit ISpac
- Product Type - 9182/10-51-11s
- Title Product Variant Technical Data - 9182/10-51-11s temperature transmitter
- WebCode - 9182A
Input
- Input for resistance temperature detector - See table
- Message of line fault and Auxilliary power failure - - Contact (30 V / 100 mA) closed to ground in case of fault - pac-Bus, floating contact (30 V / 100 mA)
Mechanical Data
- Connection cross-section - 0.2-2.5 mm² flexible 0.2-2.5 mm² rigid 0.25-2.5 mm² flexible core end sleeve
- Degree of protection (IP) - IP30
- Enclosure material - Polyamide
- Fire resistance (UL 94) - V0
- Grid dimension - 17.60 mm
- Terminal degree of protection (IP) - IP20
- Weight - 0.195 kg
Mounting / Installation
- Connection type - Screw terminal
- Mounting position - vertical horizontal
- Mounting type - DIN rail (NS35/15, NS35/7.5)
Output
- LFD relay - Yes
- Limit contact (per channel) - without
- Load resistance R L max. - 750.00 Ω
- Output - 0/4 ... 20 mA active / source
- Output functional range - 0.0 - 21.0 mA
- output signal - 0/4 - 20 mA (configurable)
- Response time output - ≤ 500 ms
- Settling time output - ≤ 35 ms
- Switching capacity fault message contact - 30 V / 100 mA
Safety Data
- Internal capacitance C i - negligible
- Internal inductance L i - negligible
- Max. Current I o - 19.7 mA
- Max. Power P o - 32.000 mW
- Max. Voltage U o - 6.50 V
- Safety-related maximum voltage - 253 V
160547
Ex i temperature transmitter, can be configured for virtually any common sensor type
broad range, including variants with signal conversion and trip amplifier function
can be used up to SIL 2 (IEC/EN 61508)
Ambient Conditions
- Ambient temperature - -20 °C ... +70 °C (Single device) -20 °C ... +60 °C (Group assembly)
- Ambient temperature max. - +70 °C
- Ambient temperature max. note - Single device
- Ambient temperature max. note 2 - Group assembly
- Ambient temperature max.2 - +60 °C
- Ambient temperature min. - -20 °C
- Ambient temperature min. 2 - -20 °C
- Ambient temperature min. note - Single device
- Ambient temperature min. note 2 - Group assembly
- Electromagnetic compatibility - Tested to the following standards and regulations: EN 61326-1 Use in industrial environment; NAMUR NE 21
- Relative humidity max. - 95%
- Storage temperature - -40 °C ... +80 °C
- Storage temperature max. - +80 °C
- Storage temperature min. - -40 °C
- Use at the height of - < 2000 m
Auxiliary power
- Auxiliary power - 24 V DC
- Auxiliary power voltage range - 18 - 31,2 V
- Nominal current - 70.00 mA
- Nominal voltage - 24 V DC
- Polarity reversal protection - yes
- Power consumption - 1.90 W
- Voltage range residual ripple - ≤ 3,6 VSS
Electrical Data
- Input potentiometer - up to 100 kΩ
- Input resistance temperature detector (RTD) - Types Pt 100, Pt 500, Pt 1000, Ni 100, Ni 500, Ni 1000
- Input resistance temperature detector (RTD) Type of circuit - 2-, 3-, 4-wire circuit
- Input thermocouple - Types B, E, J, K, N, R, S, T, L, U, XK
- Number of channels - 1
Explosion Protection
- Application range (zones) - 2, 22
- ATEX dust certificate - DMT 02 ATEX E 243 X
- ATEX gas certificate - DMT 02 ATEX E 243 X
- Certificate EAC - TS RU S-DE.GB04.B.00353
- Certificates - ATEX (BVS), Brazil (ULB), Canada (FM), EAC (STV), IECEx (BVS), India (PESO), Korea (KTL), Russia (Meteorological certificate), SIL (exida), USA (FM), USA (UL)
- Dust explosion protection ATEX - II (1) D [Ex ia Da] IIIC
- Dust explosion protection EAC - [Ex ia Da] IIIC
- Dust explosion protection IECEx - [Ex ia Da] IIIC
- Ex interface in Division NEC 500 - (Class I, II, III) 1, 2
- Ex interface zone - 0, 1, 2, 20, 21, 22
- Gas explosion protection ATEX - II 3 (1) G Ex nA nC [ia Ga] IIC T4 Gc
- Gas explosion protection EAC - 2 Ex nA nC [ia Ga] IIC T4 Gc X
- Gas explosion protection IECEx - Ex nA nC [ia Ga] IIC T4 Gc
- IECEX dust certificate - IECEx BVS 09.0046 X
- IECEX gas certificate - IECEx BVS 09.0046 X
- Installation in Division NEC 500 - (Class I, II, III) 2
- Ship approval - CCS, DNVGL
General
- Functional Description - 9182 series Ex i temperature transmitters for field circuits can be used to connect temperature sensors and potentiometers. They are easy to configure for virtually any sensor type by means of software or a DIP switch. These sensor types include Pt100 sensors, thermocouples and potentiometers. Variants with a trip amplifier function allow the input signal to be analysed using two independent contacts.
- Highlights - Ex i temperature transmitter, can be configured for virtually any common sensor type broad range, including variants with signal conversion and trip amplifier function can be used up to SIL 2 (IEC/EN 61508)
- Product Description - Temperature transmitter Ex i field circuit ISpac
- Product Type - 9182/10-51-11k
- Title Product Variant Technical Data - 9182/10-51-11k temperature transmitter
- WebCode - 9182A
Input
- Input for resistance temperature detector - See table
- Message of line fault and Auxilliary power failure - - Contact (30 V / 100 mA) closed to ground in case of fault - pac-Bus, floating contact (30 V / 100 mA)
Mechanical Data
- Degree of protection (IP) - IP30
- Enclosure material - Polyamide
- Fire resistance (UL 94) - V0
- Grid dimension - 17.60 mm
- Terminal degree of protection (IP) - IP20
- Weight - 0.195 kg
Mounting / Installation
- Connection type - Spring clamp terminal
- Mounting position - vertical horizontal
- Mounting type - NS35/15, NS35/7.5 DIN rail
Output
- LFD relay - Yes
- Limit contact (per channel) - without
- Load resistance R L max. - 750.00 Ω
- Output - 0/4 ... 20 mA active / source
- Output functional range - 0.0 - 21.0 mA
- output signal - 0/4 - 20 mA (configurable)
- Response time output - ≤ 500 ms
- Settling time output - ≤ 35 ms
- Switching capacity fault message contact - 30 V / 100 mA
Safety Data
- Internal capacitance C i - negligible
- Internal inductance L i - negligible
- Max. Current I o - 19.7 mA
- Max. Power P o - 32.000 mW
- Max. Voltage U o - 6.50 V
- Safety-related maximum voltage - 253 V
160549
Ex i temperature transmitter, can be configured for virtually any common sensor type
broad range, including variants with signal conversion and trip amplifier function
can be used up to SIL 2 (IEC/EN 61508)
Ambient Conditions
- Ambient temperature - -20 °C ... +70 °C (Single device) -20 °C ... +60 °C (Group assembly)
- Ambient temperature max. - +70 °C
- Ambient temperature max. note - Single device
- Ambient temperature max. note 2 - Group assembly
- Ambient temperature max.2 - +60 °C
- Ambient temperature min. - -20 °C
- Ambient temperature min. 2 - -20 °C
- Ambient temperature min. note - Single device
- Ambient temperature min. note 2 - Group assembly
- Electromagnetic compatibility - Tested to the following standards and regulations: EN 61326-1 Use in industrial environment; NAMUR NE 21
- Relative humidity max. - 95%
- Storage temperature - -40 °C ... +80 °C
- Storage temperature max. - +80 °C
- Storage temperature min. - -40 °C
- Use at the height of - < 2000 m
Auxiliary power
- Auxiliary power - 24 V DC
- Auxiliary power voltage range - 18 - 31,2 V
- Nominal current - 70.00 mA
- Nominal voltage - 24 V DC
- Polarity reversal protection - yes
- Power consumption - 1.90 W
- Voltage range residual ripple - ≤ 3,6 VSS
Electrical Data
- Input potentiometer - up to 100 kΩ
- Input resistance temperature detector (RTD) - Types Pt 100, Pt 500, Pt 1000, Ni 100, Ni 500, Ni 1000
- Input resistance temperature detector (RTD) Type of circuit - 2-, 3-, 4-wire circuit
- Input thermocouple - Types B, E, J, K, N, R, S, T, L, U, XK
- Number of channels - 1
Explosion Protection
- Application range (zones) - 2, 22
- ATEX dust certificate - DMT 02 ATEX E 243 X
- ATEX gas certificate - DMT 02 ATEX E 243 X
- Certificate EAC - TS RU S-DE.GB04.B.00353
- Certificates - ATEX (BVS), Brazil (ULB), Canada (FM), EAC (STV), IECEx (BVS), India (PESO), Korea (KTL), Russia (Meteorological certificate), SIL (exida), USA (FM), USA (UL)
- Dust explosion protection ATEX - II (1) D [Ex ia Da] IIIC
- Dust explosion protection EAC - [Ex ia Da] IIIC
- Dust explosion protection IECEx - [Ex ia Da] IIIC
- Ex interface in Division NEC 500 - (Class I, II, III) 1, 2
- Ex interface zone - 0, 1, 2, 20, 21, 22
- Gas explosion protection ATEX - II 3 (1) G Ex nA nC [ia Ga] IIC T4 Gc
- Gas explosion protection EAC - 2 Ex nA nC [ia Ga] IIC T4 Gc X
- Gas explosion protection IECEx - Ex nA nC [ia Ga] IIC T4 Gc
- IECEX dust certificate - IECEx BVS 09.0046 X
- IECEX gas certificate - IECEx BVS 09.0046 X
- Installation in Division NEC 500 - (Class I, II, III) 2
- Ship approval - CCS, DNVGL
General
- Functional Description - 9182 series Ex i temperature transmitters for field circuits can be used to connect temperature sensors and potentiometers. They are easy to configure for virtually any sensor type by means of software or a DIP switch. These sensor types include Pt100 sensors, thermocouples and potentiometers. Variants with a trip amplifier function allow the input signal to be analysed using two independent contacts.
- Highlights - Ex i temperature transmitter, can be configured for virtually any common sensor type broad range, including variants with signal conversion and trip amplifier function can be used up to SIL 2 (IEC/EN 61508)
- Product Description - Temperature transmitter Ex i field circuit ISpac
- Product Type - 9182/10-51-12s
- Title Product Variant Technical Data - 9182/10-51-12s temperature transmitter
- WebCode - 9182A
Input
- Input for resistance temperature detector - See table
- Message of line fault and Auxilliary power failure - - Contact (30 V / 100 mA) closed to ground in case of fault - pac-Bus, floating contact (30 V / 100 mA)
Mechanical Data
- Connection cross-section - 0.2-2.5 mm² flexible 0.2-2.5 mm² rigid 0.25-2.5 mm² flexible core end sleeve
- Degree of protection (IP) - IP30
- Enclosure material - Polyamide
- Fire resistance (UL 94) - V0
- Grid dimension - 17.60 mm
- Terminal degree of protection (IP) - IP20
- Weight - 0.195 kg
Mounting / Installation
- Connection type - Screw terminal
- Mounting position - vertical horizontal
- Mounting type - DIN rail (NS35/15, NS35/7.5)
Output
- LFD relay - Yes
- Limit contact (per channel) - 2 NO / NC
- Load resistance R L max. - 750.00 Ω
- Output - 0/4 ... 20 mA active / source
- Output functional range - 0.0 - 21.0 mA
- output signal - 0/4 - 20 mA (configurable)
- Response time output - ≤ 500 ms
- Settling time output - ≤ 35 ms
- Switching capacity fault message contact - 30 V / 100 mA
- Switching current limiting values - ≤ 100 mA
- Switching voltage limiting values - ≤ ± 30 V
Safety Data
- Internal capacitance C i - negligible
- Internal inductance L i - negligible
- Max. Current I o - 19.7 mA
- Max. Power P o - 32.000 mW
- Max. Voltage U o - 6.50 V
- Safety-related maximum voltage - 253 V
160550
Ex i temperature transmitter, can be configured for virtually any common sensor type
broad range, including variants with signal conversion and trip amplifier function
can be used up to SIL 2 (IEC/EN 61508)
Ambient Conditions
- Ambient temperature - -20 °C ... +70 °C (Single device) -20 °C ... +60 °C (Group assembly)
- Ambient temperature max. - +70 °C
- Ambient temperature max. note - Single device
- Ambient temperature max. note 2 - Group assembly
- Ambient temperature max.2 - +60 °C
- Ambient temperature min. - -20 °C
- Ambient temperature min. 2 - -20 °C
- Ambient temperature min. note - Single device
- Ambient temperature min. note 2 - Group assembly
- Electromagnetic compatibility - Tested to the following standards and regulations: EN 61326-1 Use in industrial environment; NAMUR NE 21
- Relative humidity max. - 95%
- Storage temperature - -40 °C ... +80 °C
- Storage temperature max. - +80 °C
- Storage temperature min. - -40 °C
- Use at the height of - < 2000 m
Auxiliary power
- Auxiliary power - 24 V DC
- Auxiliary power voltage range - 18 - 31,2 V
- Nominal current - 70.00 mA
- Nominal voltage - 24 V DC
- Polarity reversal protection - yes
- Power consumption - 1.90 W
- Voltage range residual ripple - ≤ 3,6 VSS
Electrical Data
- Input potentiometer - up to 100 kΩ
- Input resistance temperature detector (RTD) - Types Pt 100, Pt 500, Pt 1000, Ni 100, Ni 500, Ni 1000
- Input resistance temperature detector (RTD) Type of circuit - 2-, 3-, 4-wire circuit
- Input thermocouple - Types B, E, J, K, N, R, S, T, L, U, XK
- Number of channels - 1
Explosion Protection
- Application range (zones) - 2, 22
- ATEX dust certificate - DMT 02 ATEX E 243 X
- ATEX gas certificate - DMT 02 ATEX E 243 X
- Certificate EAC - TS RU S-DE.GB04.B.00353
- Certificates - ATEX (BVS), Brazil (ULB), Canada (FM), EAC (STV), IECEx (BVS), India (PESO), Korea (KTL), Russia (Meteorological certificate), SIL (exida), USA (FM), USA (UL)
- Dust explosion protection ATEX - II (1) D [Ex ia Da] IIIC
- Dust explosion protection EAC - [Ex ia Da] IIIC
- Dust explosion protection IECEx - [Ex ia Da] IIIC
- Ex interface in Division NEC 500 - (Class I, II, III) 1, 2
- Ex interface zone - 0, 1, 2, 20, 21, 22
- Gas explosion protection ATEX - II 3 (1) G Ex nA nC [ia Ga] IIC T4 Gc
- Gas explosion protection EAC - 2 Ex nA nC [ia Ga] IIC T4 Gc X
- Gas explosion protection IECEx - Ex nA nC [ia Ga] IIC T4 Gc
- IECEX dust certificate - IECEx BVS 09.0046 X
- IECEX gas certificate - IECEx BVS 09.0046 X
- Installation in Division NEC 500 - (Class I, II, III) 2
- Ship approval - CCS, DNVGL
General
- Functional Description - 9182 series Ex i temperature transmitters for field circuits can be used to connect temperature sensors and potentiometers. They are easy to configure for virtually any sensor type by means of software or a DIP switch. These sensor types include Pt100 sensors, thermocouples and potentiometers. Variants with a trip amplifier function allow the input signal to be analysed using two independent contacts.
- Highlights - Ex i temperature transmitter, can be configured for virtually any common sensor type broad range, including variants with signal conversion and trip amplifier function can be used up to SIL 2 (IEC/EN 61508)
- Product Description - Temperature transmitter Ex i field circuit ISpac
- Product Type - 9182/10-51-12k
- Title Product Variant Technical Data - 9182/10-51-12k temperature transmitter
- WebCode - 9182A
Input
- Input for resistance temperature detector - See table
- Message of line fault and Auxilliary power failure - - Contact (30 V / 100 mA) closed to ground in case of fault - pac-Bus, floating contact (30 V / 100 mA)
Mechanical Data
- Degree of protection (IP) - IP30
- Enclosure material - Polyamide
- Fire resistance (UL 94) - V0
- Grid dimension - 17.60 mm
- Terminal degree of protection (IP) - IP20
- Weight - 0.195 kg
Mounting / Installation
- Connection type - Spring clamp terminal
- Mounting position - vertical horizontal
- Mounting type - NS35/15, NS35/7.5 DIN rail
Output
- LFD relay - Yes
- Limit contact (per channel) - 2 NO / NC
- Load resistance R L max. - 750.00 Ω
- Output - 0/4 ... 20 mA active / source
- Output functional range - 0.0 - 21.0 mA
- output signal - 0/4 - 20 mA (configurable)
- Response time output - ≤ 500 ms
- Settling time output - ≤ 35 ms
- Switching capacity fault message contact - 30 V / 100 mA
- Switching current limiting values - ≤ 100 mA
- Switching voltage limiting values - ≤ ± 30 V
Safety Data
- Internal capacitance C i - negligible
- Internal inductance L i - negligible
- Max. Current I o - 19.7 mA
- Max. Power P o - 32.000 mW
- Max. Voltage U o - 6.50 V
- Safety-related maximum voltage - 253 V
201653
Ex i temperature transmitter, can be configured for virtually any common sensor type
broad range, including variants with signal conversion and trip amplifier function
can be used up to SIL 2 (IEC/EN 61508)
Ambient Conditions
- Ambient temperature - -20 °C ... +70 °C (Single device) -20 °C ... +60 °C (Group assembly)
- Ambient temperature max. - +70 °C
- Ambient temperature max. note - Single device
- Ambient temperature max. note 2 - Group assembly
- Ambient temperature max.2 - +60 °C
- Ambient temperature min. - -20 °C
- Ambient temperature min. 2 - -20 °C
- Ambient temperature min. note - Single device
- Ambient temperature min. note 2 - Group assembly
- Electromagnetic compatibility - Tested to the following standards and regulations: EN 61326-1 Use in industrial environment; NAMUR NE 21
- Relative humidity max. - 95%
- Storage temperature - -40 °C ... +80 °C
- Storage temperature max. - +80 °C
- Storage temperature min. - -40 °C
- Use at the height of - < 2000 m
Auxiliary power
- Auxiliary power - 24 V DC
- Auxiliary power voltage range - 18 - 31,2 V
- Nominal current - 70.00 mA
- Nominal voltage - 24 V DC
- Polarity reversal protection - yes
- Power consumption - 1.90 W
- Voltage range residual ripple - ≤ 3,6 VSS
Electrical Data
- Input potentiometer - up to 100 kΩ
- Input resistance temperature detector (RTD) - Types Pt 100, Pt 500, Pt 1000, Ni 100, Ni 500, Ni 1000
- Input resistance temperature detector (RTD) Type of circuit - 2-, 3-, 4-wire circuit
- Input thermocouple - Types B, E, J, K, N, R, S, T, L, U, XK
- Number of channels - 1
Explosion Protection
- Application range (zones) - 2, 22
- ATEX dust certificate - DMT 02 ATEX E 243 X
- ATEX gas certificate - DMT 02 ATEX E 243 X
- Certificate EAC - TS RU S-DE.GB04.B.00353
- Certificates - ATEX (BVS), Brazil (ULB), Canada (FM), EAC (STV), IECEx (BVS), India (PESO), Korea (KTL), Russia (Meteorological certificate), SIL (exida), USA (FM)
- Dust explosion protection ATEX - II (1) D [Ex ia Da] IIIC
- Dust explosion protection EAC - [Ex ia Da] IIIC
- Dust explosion protection IECEx - [Ex ia Da] IIIC
- Ex interface in Division NEC 500 - (Class I, II, III) 1, 2
- Ex interface zone - 0, 1, 2, 20, 21, 22
- Gas explosion protection ATEX - II 3 (1) G Ex nA nC [ia Ga] IIC T4 Gc
- Gas explosion protection EAC - 2 Ex nA nC [ia Ga] IIC T4 Gc X
- Gas explosion protection IECEx - Ex nA nC [ia Ga] IIC T4 Gc
- IECEX dust certificate - IECEx BVS 09.0046 X
- IECEX gas certificate - IECEx BVS 09.0046 X
- Installation in Division NEC 500 - (Class I, II, III) 2
- Ship approval - CCS, DNVGL
General
- Functional Description - 9182 series Ex i temperature transmitters for field circuits can be used to connect temperature sensors and potentiometers. They are easy to configure for virtually any sensor type by means of software or a DIP switch. These sensor types include Pt100 sensors, thermocouples and potentiometers. Variants with a trip amplifier function allow the input signal to be analysed using two independent contacts.
- Highlights - Ex i temperature transmitter, can be configured for virtually any common sensor type broad range, including variants with signal conversion and trip amplifier function can be used up to SIL 2 (IEC/EN 61508)
- Product Description - Temperature transmitter Ex i field circuit ISpac
- Product Type - 9182/10-51-13s
- Title Product Variant Technical Data - 9182/10-51-13s temperature transmitter
- WebCode - 9182A
Input
- Input for resistance temperature detector - See table
- Message of line fault and Auxilliary power failure - - Contact (30 V / 100 mA) closed to ground in case of fault - pac-Bus, floating contact (30 V / 100 mA)
Mechanical Data
- Connection cross-section - 0.2-2.5 mm² flexible 0.2-2.5 mm² rigid 0.25-2.5 mm² flexible core end sleeve
- Degree of protection (IP) - IP30
- Enclosure material - Polyamide
- Fire resistance (UL 94) - V0
- Grid dimension - 17.60 mm
- Terminal degree of protection (IP) - IP20
- Weight - 0.170 kg
Mounting / Installation
- Connection type - Screw terminal
- Mounting position - vertical horizontal
- Mounting type - DIN rail (NS35/15, NS35/7.5)
Output
- LFD relay - Yes
- Limit contact (per channel) - without
- Load resistance R L max. - 750.00 Ω
- Output - 0/4 ... 20 mA active / source
- Output functional range - 0.0 - 21.0 mA
- output signal - 0/4 - 20 mA (configurable)
- Response time output - ≤ 500 ms
- Settling time output - ≤ 35 ms
- Switching capacity fault message contact - 30 V / 100 mA
Safety Data
- Max. Current I o - 19.7 mA
- Max. Power P o - 32.000 mW
- Max. Voltage U o - 6.50 V
- Safety-related maximum voltage - 253 V
201654
Ex i temperature transmitter, can be configured for virtually any common sensor type
broad range, including variants with signal conversion and trip amplifier function
can be used up to SIL 2 (IEC/EN 61508)
Ambient Conditions
- Ambient temperature - -20 °C ... +70 °C (Single device) -20 °C ... +60 °C (Group assembly)
- Ambient temperature max. - +70 °C
- Ambient temperature max. note - Single device
- Ambient temperature max. note 2 - Group assembly
- Ambient temperature max.2 - +60 °C
- Ambient temperature min. - -20 °C
- Ambient temperature min. 2 - -20 °C
- Ambient temperature min. note - Single device
- Ambient temperature min. note 2 - Group assembly
- Electromagnetic compatibility - Tested to the following standards and regulations: EN 61326-1 Use in industrial environment; NAMUR NE 21
- Relative humidity max. - 95%
- Storage temperature - -40 °C ... +80 °C
- Storage temperature max. - +80 °C
- Storage temperature min. - -40 °C
- Use at the height of - < 2000 m
Auxiliary power
- Auxiliary power - 24 V DC
- Auxiliary power voltage range - 18 - 31,2 V
- Nominal current - 70.00 mA
- Nominal voltage - 24 V DC
- Polarity reversal protection - yes
- Power consumption - 1.90 W
- Voltage range residual ripple - ≤ 3,6 VSS
Electrical Data
- Input potentiometer - up to 100 kΩ
- Input resistance temperature detector (RTD) - Types Pt 100, Pt 500, Pt 1000, Ni 100, Ni 500, Ni 1000
- Input resistance temperature detector (RTD) Type of circuit - 2-, 3-, 4-wire circuit
- Input thermocouple - Types B, E, J, K, N, R, S, T, L, U, XK
- Number of channels - 1
Explosion Protection
- Application range (zones) - 2, 22
- ATEX dust certificate - DMT 02 ATEX E 243 X
- ATEX gas certificate - DMT 02 ATEX E 243 X
- Certificate EAC - TS RU S-DE.GB04.B.00353
- Certificates - ATEX (BVS), Brazil (ULB), Canada (FM), EAC (STV), IECEx (BVS), India (PESO), Korea (KTL), Russia (Meteorological certificate), SIL (exida), USA (FM)
- Dust explosion protection ATEX - II (1) D [Ex ia Da] IIIC
- Dust explosion protection EAC - [Ex ia Da] IIIC
- Dust explosion protection IECEx - [Ex ia Da] IIIC
- Ex interface in Division NEC 500 - (Class I, II, III) 1, 2
- Ex interface zone - 0, 1, 2, 20, 21, 22
- Gas explosion protection ATEX - II 3 (1) G Ex nA nC [ia Ga] IIC T4 Gc
- Gas explosion protection EAC - 2 Ex nA nC [ia Ga] IIC T4 Gc X
- Gas explosion protection IECEx - Ex nA nC [ia Ga] IIC T4 Gc
- IECEX dust certificate - IECEx BVS 09.0046 X
- IECEX gas certificate - IECEx BVS 09.0046 X
- Installation in Division NEC 500 - (Class I, II, III) 2
- Ship approval - CCS, DNVGL
General
- Functional Description - 9182 series Ex i temperature transmitters for field circuits can be used to connect temperature sensors and potentiometers. They are easy to configure for virtually any sensor type by means of software or a DIP switch. These sensor types include Pt100 sensors, thermocouples and potentiometers. Variants with a trip amplifier function allow the input signal to be analysed using two independent contacts.
- Highlights - Ex i temperature transmitter, can be configured for virtually any common sensor type broad range, including variants with signal conversion and trip amplifier function can be used up to SIL 2 (IEC/EN 61508)
- Product Description - Temperature transmitter Ex i field circuit ISpac
- Product Type - 9182/10-51-13k
- Title Product Variant Technical Data - 9182/10-51-13k temperature transmitter
- WebCode - 9182A
Input
- Input for resistance temperature detector - See table
- Message of line fault and Auxilliary power failure - - Contact (30 V / 100 mA) closed to ground in case of fault - pac-Bus, floating contact (30 V / 100 mA)
Mechanical Data
- Degree of protection (IP) - IP30
- Enclosure material - Polyamide
- Fire resistance (UL 94) - V0
- Grid dimension - 17.60 mm
- Terminal degree of protection (IP) - IP20
- Weight - 0.170 kg
Mounting / Installation
- Connection type - Spring clamp terminal
- Mounting position - horizontal vertical
- Mounting type - NS35/15, NS35/7.5 DIN rail
Output
- LFD relay - Yes
- Limit contact (per channel) - without
- Load resistance R L max. - 750.00 Ω
- Output - 0/4 ... 20 mA active / source
- Output functional range - 0.0 - 21.0 mA
- output signal - 0/4 - 20 mA (configurable)
- Response time output - ≤ 500 ms
- Settling time output - ≤ 35 ms
- Switching capacity fault message contact - 30 V / 100 mA
Safety Data
- Max. Current I o - 19.7 mA
- Max. Power P o - 32.000 mW
- Max. Voltage U o - 6.50 V
- Safety-related maximum voltage - 253 V
201657
Ex i temperature transmitter, can be configured for virtually any common sensor type
broad range, including variants with signal conversion and trip amplifier function
can be used up to SIL 2 (IEC/EN 61508)
Ambient Conditions
- Ambient temperature - -20 °C ... +70 °C (Single device) -20 °C ... +60 °C (Group assembly)
- Ambient temperature max. - +70 °C
- Ambient temperature max. note - Single device
- Ambient temperature max. note 2 - Group assembly
- Ambient temperature max.2 - +60 °C
- Ambient temperature min. - -20 °C
- Ambient temperature min. 2 - -20 °C
- Ambient temperature min. note - Single device
- Ambient temperature min. note 2 - Group assembly
- Electromagnetic compatibility - Tested to the following standards and regulations: EN 61326-1 Use in industrial environment; NAMUR NE 21
- Relative humidity max. - 95%
- Storage temperature - -40 °C ... +80 °C
- Storage temperature max. - +80 °C
- Storage temperature min. - -40 °C
- Use at the height of - < 2000 m
Auxiliary power
- Auxiliary power - 24 V DC
- Auxiliary power voltage range - 18 - 31,2 V
- Nominal current - 70.00 mA
- Nominal voltage - 24 V DC
- Polarity reversal protection - yes
- Power consumption - 1.90 W
- Voltage range residual ripple - ≤ 3,6 VSS
Electrical Data
- Input potentiometer - up to 100 kΩ
- Input resistance temperature detector (RTD) - Types Pt 100, Pt 500, Pt 1000, Ni 100, Ni 500, Ni 1000
- Input resistance temperature detector (RTD) Type of circuit - 2-, 3-, 4-wire circuit
- Input thermocouple - Types B, E, J, K, N, R, S, T, L, U, XK
- Number of channels - 1
Explosion Protection
- Application range (zones) - 2, 22
- ATEX dust certificate - DMT 02 ATEX E 243 X
- ATEX gas certificate - DMT 02 ATEX E 243 X
- Certificate EAC - TS RU S-DE.GB04.B.00353
- Certificates - ATEX (BVS), Brazil (ULB), Canada (FM), EAC (STV), IECEx (BVS), India (PESO), Korea (KTL), Russia (Meteorological certificate), SIL (exida), USA (FM)
- Dust explosion protection ATEX - II (1) D [Ex ia Da] IIIC
- Dust explosion protection EAC - [Ex ia Da] IIIC
- Dust explosion protection IECEx - [Ex ia Da] IIIC
- Ex interface in Division NEC 500 - (Class I, II, III) 1, 2
- Ex interface zone - 0, 1, 2, 20, 21, 22
- Gas explosion protection ATEX - II 3 (1) G Ex nA nC [ia Ga] IIC T4 Gc
- Gas explosion protection EAC - 2 Ex nA nC [ia Ga] IIC T4 Gc X
- Gas explosion protection IECEx - Ex nA nC [ia Ga] IIC T4 Gc
- IECEX dust certificate - IECEx BVS 09.0046 X
- IECEX gas certificate - IECEx BVS 09.0046 X
- Installation in Division NEC 500 - (Class I, II, III) 2
- Ship approval - CCS, DNVGL
General
- Functional Description - 9182 series Ex i temperature transmitters for field circuits can be used to connect temperature sensors and potentiometers. They are easy to configure for virtually any sensor type by means of software or a DIP switch. These sensor types include Pt100 sensors, thermocouples and potentiometers. Variants with a trip amplifier function allow the input signal to be analysed using two independent contacts.
- Highlights - Ex i temperature transmitter, can be configured for virtually any common sensor type broad range, including variants with signal conversion and trip amplifier function can be used up to SIL 2 (IEC/EN 61508)
- Product Description - Temperature transmitter Ex i field circuit ISpac
- Product Type - 9182/10-59-13s
- Title Product Variant Technical Data - 9182/10-59-13s temperature transmitter
- WebCode - 9182A
Input
- Input for resistance temperature detector - See table
- Message of line fault and Auxilliary power failure - - Contact (30 V / 100 mA) closed to ground in case of fault - pac-Bus, floating contact (30 V / 100 mA)
Mechanical Data
- Connection cross-section - 0.2-2.5 mm² flexible 0.2-2.5 mm² rigid 0.25-2.5 mm² flexible core end sleeve
- Degree of protection (IP) - IP30
- Enclosure material - Polyamide
- Fire resistance (UL 94) - V0
- Grid dimension - 17.60 mm
- Terminal degree of protection (IP) - IP20
- Weight - 0.170 kg
Mounting / Installation
- Connection type - Screw terminal
- Mounting position - vertical horizontal
- Mounting type - DIN rail (NS35/15, NS35/7.5)
Output
- LFD relay - Yes
- Limit contact (per channel) - without
- Load resistance R L max. - 750.00 Ω
- Output - 0/4 ... 20 mA passive / sink
- output signal - 0/4 ... 0 mA pas./sink (con.)
- Response time output - ≤ 500 ms
- Settling time output - ≤ 35 ms
- Switching capacity fault message contact - 30 V / 100 mA
Safety Data
- Max. Current I o - 19.7 mA
- Max. Power P o - 32.000 mW
- Max. Voltage U o - 6.50 V
- Safety-related maximum voltage - 253 V
201658
Ex i temperature transmitter, can be configured for virtually any common sensor type
broad range, including variants with signal conversion and trip amplifier function
can be used up to SIL 2 (IEC/EN 61508)
Ambient Conditions
- Ambient temperature - -20 °C ... +70 °C (Single device) -20 °C ... +60 °C (Group assembly)
- Ambient temperature max. - +70 °C
- Ambient temperature max. note - Single device
- Ambient temperature max. note 2 - Group assembly
- Ambient temperature max.2 - +60 °C
- Ambient temperature min. - -20 °C
- Ambient temperature min. 2 - -20 °C
- Ambient temperature min. note - Single device
- Ambient temperature min. note 2 - Group assembly
- Electromagnetic compatibility - Tested to the following standards and regulations: EN 61326-1 Use in industrial environment; NAMUR NE 21
- Relative humidity max. - 95%
- Storage temperature - -40 °C ... +80 °C
- Storage temperature max. - +80 °C
- Storage temperature min. - -40 °C
- Use at the height of - < 2000 m
Auxiliary power
- Auxiliary power - 24 V DC
- Auxiliary power voltage range - 18 - 31,2 V
- Nominal current - 70.00 mA
- Nominal voltage - 24 V DC
- Polarity reversal protection - yes
- Power consumption - 1.90 W
- Voltage range residual ripple - ≤ 3,6 VSS
Electrical Data
- Input potentiometer - up to 100 kΩ
- Input resistance temperature detector (RTD) - Types Pt 100, Pt 500, Pt 1000, Ni 100, Ni 500, Ni 1000
- Input resistance temperature detector (RTD) Type of circuit - 2-, 3-, 4-wire circuit
- Input thermocouple - Types B, E, J, K, N, R, S, T, L, U, XK
- Number of channels - 1
Explosion Protection
- Application range (zones) - 2, 22
- ATEX dust certificate - DMT 02 ATEX E 243 X
- ATEX gas certificate - DMT 02 ATEX E 243 X
- Certificate EAC - TS RU S-DE.GB04.B.00353
- Certificates - ATEX (BVS), Brazil (ULB), Canada (FM), EAC (STV), IECEx (BVS), India (PESO), Korea (KTL), Russia (Meteorological certificate), SIL (exida), USA (FM)
- Dust explosion protection ATEX - II (1) D [Ex ia Da] IIIC
- Dust explosion protection EAC - [Ex ia Da] IIIC
- Dust explosion protection IECEx - [Ex ia Da] IIIC
- Ex interface in Division NEC 500 - (Class I, II, III) 1, 2
- Ex interface zone - 0, 1, 2, 20, 21, 22
- Gas explosion protection ATEX - II 3 (1) G Ex nA nC [ia Ga] IIC T4 Gc
- Gas explosion protection EAC - 2 Ex nA nC [ia Ga] IIC T4 Gc X
- Gas explosion protection IECEx - Ex nA nC [ia Ga] IIC T4 Gc
- IECEX dust certificate - IECEx BVS 09.0046 X
- IECEX gas certificate - IECEx BVS 09.0046 X
- Installation in Division NEC 500 - (Class I, II, III) 2
- Ship approval - CCS, DNVGL
General
- Functional Description - 9182 series Ex i temperature transmitters for field circuits can be used to connect temperature sensors and potentiometers. They are easy to configure for virtually any sensor type by means of software or a DIP switch. These sensor types include Pt100 sensors, thermocouples and potentiometers. Variants with a trip amplifier function allow the input signal to be analysed using two independent contacts.
- Highlights - Ex i temperature transmitter, can be configured for virtually any common sensor type broad range, including variants with signal conversion and trip amplifier function can be used up to SIL 2 (IEC/EN 61508)
- Product Description - Temperature transmitter Ex i field circuit ISpac
- Product Type - 9182/10-59-13k
- Title Product Variant Technical Data - 9182/10-59-13k temperature transmitter
- WebCode - 9182A
Input
- Input for resistance temperature detector - See table
- Message of line fault and Auxilliary power failure - - Contact (30 V / 100 mA) closed to ground in case of fault - pac-Bus, floating contact (30 V / 100 mA)
Mechanical Data
- Degree of protection (IP) - IP30
- Enclosure material - Polyamide
- Fire resistance (UL 94) - V0
- Grid dimension - 17.60 mm
- Terminal degree of protection (IP) - IP20
- Weight - 0.205 kg
Mounting / Installation
- Connection type - Spring clamp terminal
- Mounting position - horizontal vertical
- Mounting type - NS35/15, NS35/7.5 DIN rail
Output
- LFD relay - Yes
- Limit contact (per channel) - without
- Load resistance R L max. - 750.00 Ω
- Output - 0/4 ... 20 mA passive / sink
- output signal - 0/4 ... 0 mA pas./sink (con.)
- Response time output - ≤ 500 ms
- Settling time output - ≤ 35 ms
- Switching capacity fault message contact - 30 V / 100 mA
Safety Data
- Max. Current I o - 19.7 mA
- Max. Power P o - 32.000 mW
- Max. Voltage U o - 6.50 V
- Safety-related maximum voltage - 253 V
201682
Ex i temperature transmitter, can be configured for virtually any common sensor type
broad range, including variants with signal conversion and trip amplifier function
can be used up to SIL 2 (IEC/EN 61508)
Ambient Conditions
- Ambient temperature - -20 °C ... +70 °C (Single device) -20 °C ... +60 °C (Group assembly)
- Ambient temperature max. - +70 °C
- Ambient temperature max. note - Single device
- Ambient temperature max. note 2 - Group assembly
- Ambient temperature max.2 - +60 °C
- Ambient temperature min. - -20 °C
- Ambient temperature min. 2 - -20 °C
- Ambient temperature min. note - Single device
- Ambient temperature min. note 2 - Group assembly
- Electromagnetic compatibility - Tested to the following standards and regulations: EN 61326-1 Use in industrial environment; NAMUR NE 21
- Relative humidity max. - 95%
- Storage temperature - -40 °C ... +80 °C
- Storage temperature max. - +80 °C
- Storage temperature min. - -40 °C
- Use at the height of - < 2000 m
Auxiliary power
- Auxiliary power - 24 V DC
- Auxiliary power voltage range - 18 - 31,2 V
- Nominal current - 70.00 mA
- Nominal voltage - 24 V DC
- Polarity reversal protection - yes
- Power consumption - 1.90 W
- Voltage range residual ripple - ≤ 3,6 VSS
Electrical Data
- Input potentiometer - up to 100 kΩ
- Input resistance temperature detector (RTD) - Types Pt 100, Pt 500, Pt 1000, Ni 100, Ni 500, Ni 1000
- Input resistance temperature detector (RTD) Type of circuit - 2-, 3-, 4-wire circuit
- Input thermocouple - Types B, E, J, K, N, R, S, T, L, U, XK
- Number of channels - 1
Explosion Protection
- Application range (zones) - 2, 22
- ATEX dust certificate - DMT 02 ATEX E 243 X
- ATEX gas certificate - DMT 02 ATEX E 243 X
- Certificate EAC - TS RU S-DE.GB04.B.00353
- Certificates - ATEX (BVS), Brazil (ULB), Canada (FM), EAC (STV), IECEx (BVS), India (PESO), Korea (KTL), Russia (Meteorological certificate), SIL (exida), USA (FM)
- Dust explosion protection ATEX - II (1) D [Ex ia Da] IIIC
- Dust explosion protection EAC - [Ex ia Da] IIIC
- Dust explosion protection IECEx - [Ex ia Da] IIIC
- Ex interface in Division NEC 500 - (Class I, II, III) 1, 2
- Ex interface zone - 0, 1, 2, 20, 21, 22
- Gas explosion protection ATEX - II 3 (1) G Ex nA nC [ia Ga] IIC T4 Gc
- Gas explosion protection EAC - 2 Ex nA nC [ia Ga] IIC T4 Gc X
- Gas explosion protection IECEx - Ex nA nC [ia Ga] IIC T4 Gc
- IECEX dust certificate - IECEx BVS 09.0046 X
- IECEX gas certificate - IECEx BVS 09.0046 X
- Installation in Division NEC 500 - (Class I, II, III) 2
- Ship approval - CCS, DNVGL
General
- Functional Description - 9182 series Ex i temperature transmitters for field circuits can be used to connect temperature sensors and potentiometers. They are easy to configure for virtually any sensor type by means of software or a DIP switch. These sensor types include Pt100 sensors, thermocouples and potentiometers. Variants with a trip amplifier function allow the input signal to be analysed using two independent contacts.
- Highlights - Ex i temperature transmitter, can be configured for virtually any common sensor type broad range, including variants with signal conversion and trip amplifier function can be used up to SIL 2 (IEC/EN 61508)
- Product Description - Temperature transmitter Ex i field circuit ISpac
- Product Type - 9182/10-51-14s
- Title Product Variant Technical Data - 9182/10-51-14s temperature transmitter
- WebCode - 9182A
Input
- Input for resistance temperature detector - See table
- Message of line fault and Auxilliary power failure - - Contact (30 V / 100 mA) closed to ground in case of fault - pac-Bus, floating contact (30 V / 100 mA)
Mechanical Data
- Connection cross-section - 0.2-2.5 mm² flexible 0.2-2.5 mm² rigid 0.25-2.5 mm² flexible core end sleeve
- Degree of protection (IP) - IP30
- Enclosure material - Polyamide
- Fire resistance (UL 94) - V0
- Grid dimension - 17.60 mm
- Terminal degree of protection (IP) - IP20
- Weight - 0.170 kg
Mounting / Installation
- Connection type - Screw terminal
- Mounting position - vertical horizontal
- Mounting type - DIN rail (NS35/15, NS35/7.5)
Output
- LFD relay - Yes
- Limit contact (per channel) - 2 NO / NC
- Load resistance R L max. - 750.00 Ω
- Output - 0/4 ... 20 mA active / source
- Output functional range - 0.0 - 21.0 mA
- output signal - 0/4 - 20 mA (configurable)
- Response time output - ≤ 500 ms
- Settling time output - ≤ 35 ms
- Switching capacity fault message contact - 30 V / 100 mA
- Switching current limiting values - ≤ 100 mA
- Switching voltage limiting values - ≤ ± 30 V
Safety Data
- Max. Current I o - 19.7 mA
- Max. Power P o - 32.000 mW
- Max. Voltage U o - 6.50 V
- Safety-related maximum voltage - 253 V
201683
Ex i temperature transmitter, can be configured for virtually any common sensor type
broad range, including variants with signal conversion and trip amplifier function
can be used up to SIL 2 (IEC/EN 61508)
Ambient Conditions
- Ambient temperature - -20 °C ... +70 °C (Single device) -20 °C ... +60 °C (Group assembly)
- Ambient temperature max. - +70 °C
- Ambient temperature max. note - Single device
- Ambient temperature max. note 2 - Group assembly
- Ambient temperature max.2 - +60 °C
- Ambient temperature min. - -20 °C
- Ambient temperature min. 2 - -20 °C
- Ambient temperature min. note - Single device
- Ambient temperature min. note 2 - Group assembly
- Electromagnetic compatibility - Tested to the following standards and regulations: EN 61326-1 Use in industrial environment; NAMUR NE 21
- Relative humidity max. - 95%
- Storage temperature - -40 °C ... +80 °C
- Storage temperature max. - +80 °C
- Storage temperature min. - -40 °C
- Use at the height of - < 2000 m
Auxiliary power
- Auxiliary power - 24 V DC
- Auxiliary power voltage range - 18 - 31,2 V
- Nominal current - 70.00 mA
- Nominal voltage - 24 V DC
- Polarity reversal protection - yes
- Power consumption - 1.90 W
- Voltage range residual ripple - ≤ 3,6 VSS
Electrical Data
- Input potentiometer - up to 100 kΩ
- Input resistance temperature detector (RTD) - Types Pt 100, Pt 500, Pt 1000, Ni 100, Ni 500, Ni 1000
- Input resistance temperature detector (RTD) Type of circuit - 2-, 3-, 4-wire circuit
- Input thermocouple - Types B, E, J, K, N, R, S, T, L, U, XK
- Number of channels - 1
Explosion Protection
- Application range (zones) - 2, 22
- ATEX dust certificate - DMT 02 ATEX E 243 X
- ATEX gas certificate - DMT 02 ATEX E 243 X
- Certificate EAC - TS RU S-DE.GB04.B.00353
- Certificates - ATEX (BVS), Brazil (ULB), Canada (FM), EAC (STV), IECEx (BVS), India (PESO), Korea (KTL), Russia (Meteorological certificate), SIL (exida), USA (FM)
- Dust explosion protection ATEX - II (1) D [Ex ia Da] IIIC
- Dust explosion protection EAC - [Ex ia Da] IIIC
- Dust explosion protection IECEx - [Ex ia Da] IIIC
- Ex interface in Division NEC 500 - (Class I, II, III) 1, 2
- Ex interface zone - 0, 1, 2, 20, 21, 22
- Gas explosion protection ATEX - II 3 (1) G Ex nA nC [ia Ga] IIC T4 Gc
- Gas explosion protection EAC - 2 Ex nA nC [ia Ga] IIC T4 Gc X
- Gas explosion protection IECEx - Ex nA nC [ia Ga] IIC T4 Gc
- IECEX dust certificate - IECEx BVS 09.0046 X
- IECEX gas certificate - IECEx BVS 09.0046 X
- Installation in Division NEC 500 - (Class I, II, III) 2
- Ship approval - CCS, DNVGL
General
- Functional Description - 9182 series Ex i temperature transmitters for field circuits can be used to connect temperature sensors and potentiometers. They are easy to configure for virtually any sensor type by means of software or a DIP switch. These sensor types include Pt100 sensors, thermocouples and potentiometers. Variants with a trip amplifier function allow the input signal to be analysed using two independent contacts.
- Highlights - Ex i temperature transmitter, can be configured for virtually any common sensor type broad range, including variants with signal conversion and trip amplifier function can be used up to SIL 2 (IEC/EN 61508)
- Product Description - Temperature transmitter Ex i field circuit ISpac
- Product Type - 9182/10-51-14k
- Title Product Variant Technical Data - 9182/10-51-14k temperature transmitter
- WebCode - 9182A
Input
- Input for resistance temperature detector - See table
- Message of line fault and Auxilliary power failure - - Contact (30 V / 100 mA) closed to ground in case of fault - pac-Bus, floating contact (30 V / 100 mA)
Mechanical Data
- Degree of protection (IP) - IP30
- Enclosure material - Polyamide
- Fire resistance (UL 94) - V0
- Grid dimension - 17.60 mm
- Terminal degree of protection (IP) - IP20
- Weight - 170.000 kg
Mounting / Installation
- Connection type - Spring clamp terminal
- Mounting position - horizontal vertical
- Mounting type - NS35/15, NS35/7.5 DIN rail
Output
- LFD relay - Yes
- Limit contact (per channel) - 2 NO / NC
- Load resistance R L max. - 750.00 Ω
- Output - 0/4 ... 20 mA active / source
- Output functional range - 0.0 - 21.0 mA
- output signal - 0/4 - 20 mA (configurable)
- Response time output - ≤ 500 ms
- Settling time output - ≤ 35 ms
- Switching capacity fault message contact - 30 V / 100 mA
- Switching current limiting values - ≤ 100 mA
- Switching voltage limiting values - ≤ ± 30 V
Safety Data
- Max. Current I o - 19.7 mA
- Max. Power P o - 32.000 mW
- Max. Voltage U o - 6.50 V
- Safety-related maximum voltage - 253 V
1 - 12 of 12 Part Numbers