Features
  • Input Supply
    • 1Ø Input 208/230 volt 2 - 5 HP 
    • 3Ø Input 208/230 volt 2 - 15 HP 
    • 3Ø Input 460 volt 2 - 30 HP
    •  (208 – 240V ± 10%, 15 – 70 Hz) 
    • (380 – 460V ± 10%, 15 – 70 Hz)
  • Motor Requirements
    • 3 phase, TEFC, 208 – 230V or
    • 60V, 0 – 60 HZ, Class F insulation, NEMA design A  or B.
  • Motor mount to fan cover of TEFC motor for a packaged unit with a small footprint.
  • Maximum ambient temperature 104º F.
  • Indoor enclosure
    • NEMA 1. Avoid excessive dust, corrosives, salts and direct sunlight.
  • Display
    • Large LCD display.
    • Easy to read pump language, pump on, system pressure, fault codes and system conditions are displayed.
  • Control up to 8 pumps in parallel
  • Control
    • Analog input control (4 – 20mA) two point control based on pressure, flow or differential pressure.
  • Alternate Input
    • Up to two transducers may be used with each controller.
    • These may be pressure, flow, differential pressure, temperature or other 4 – 20mA signals.
  • Remote start/stop via switch input (low water, low pressure, etc.) and emergency stop.
  • Dry relay contacts available for pump run and fault.
  • Protection
    • Over/Under voltage, motor overload, short circuit, ground fault, programmable no/low flow shutdown, low suction pressure, pump run-out.
  • MODBUS® and BACnet as standard. Optional Wi-Fi card for the flexibility of wireless connection.
  • Advanced motor control to reduce heating and extend the lifetime of the motor.
  • Embedded THDi filter for better electricity quality from the grid, extending the lifetime of the equipment.
  • Pressure Transducer
    • 316 SS, 17-4 PH stainless steel,  ¼“ NPT connection, shielded two wire cable, 0 – 300 PSI range.
    • Included with drive.

Specifications

e-SV Packaged Hydrovar

  • Flow rate: up to 725 GPM
  • Head: up to 1,080’ TDH
  • Input supply: 1Ø Input 208/230 volt 2 - 5 HP 3Ø Input 208/230 volt 2 - 15 HP 3Ø Input 460 volt 2 - 30 HP (208 - 240 V ± 10 %, 15 - 70 Hz) (380 - 460 V ± 10 %, 15 - 70 Hz)
  • Output voltage: 3Ø , 230 V 2 - 15 HP, 3Ø , 460 V 2 - 30 HP
  • Input frequency: 50 or 60 Hz
  • External control voltage: 0-5 Vdc, 0-10 Vdc, 0-20 mA
  • Protection Class: panel: NEMA 4X drive: NEMA 1 up to 30 HP
  • Maximum HP: 30 HP
  • Soft motor start
  • Vertical design pump: e-SV series (motor insulation class, °F, TEFC enclosure) — Max. operating pressure: 360 psi — Max. temperature of pumped liquid: 250° F

Aquavar® IPC

  • Indoor enclosures: IP20 open, Type 1, Type 12
  • Outdoor enclosures: Type 3R, Type 4X
  • Input supply: 1.5 - 600 HP (frame A - D) wall or base mounted
  • Ambient temperature: 14° F - 113° F (-10° C - 45° C), Higher temperatures can be achieved by derating the output amperage of the drive 10 % for up to 122° F (50° C).
  • Communication: Modbus RTU, Metasys N2, FLN, and BACnet standard. Others available with option cards
  • Relative humidity: Lower than 95 % without condensation
  • Altitudes: At altitudes from 0 to 1000 meters (0 to 3300 feet). Nameplate rated current is available. Derate for altitudes above 1000 (3300 feet) with a Max. operating altitude of 3000 meters (9900 feet). Consult factory for applications above 3000 meters (9900 feet).
  • Electrical - input power: 1-Phase 200 V to 240 V ± 10 % 3-Phase 380 V to 480 V ± 10 % 3-Phase 200 V to 240 V ± 10 % 3-Phase 525 V to 600 V ± 10 % Frequency 50 or 60 Hz, ± 2 Hz
  • Electrical - output power: 3-Phase from 0 to V supply

Hydrovar®

  • Input supply (from 2 hp to 30 hp): 1Ø Input 208/230 V 2 - 5 HP (208-240 V ± 10 %) 3Ø Input 208/230 V 2 - 15 HP (208-240 V ± 10 %) 3Ø Input 460 V 2 - 30 HP (380-460 V ± 10 %)
  • Speed: from 15-70 Hz
  • Power supply: Single or three phase 50 or 60 Hz
  • Motor requirements: 3-Phase, TEFC, 208 - 230 V or 460 V, 0 - 60 Hz, Class F insulation, NEMA design A or B. Motor to fan cover of TEFC motor for a packaged unit with a small footprint.
  • Maximum ambient temperature: 104° F
  • Indoor enclosure: NEMA 1. Avoid excessive dust, corrosives, salts and direct sunlight.
  • Communication: RS-485 interface, BACnet, Modbus

  • Designed for centrifugal pump systems requiring constant pressure, flow control or differential pressure in commercial and municipal applications.

Documentation

Instantly populate your store or catalog 
CREATE YOUR SITE
or book a demo with the Yodify Team
show more