Brand: R. STAHL AGR. STAHL Series 8570/22 SolConeX plugs for Zone 1/21 are silicone-free 3-, 4- or 5-pole 16 A plugs.
The floating pins allow them to be inserted and removed quickly and easily.
The pivoting strain relief makes it easier to install the cable.
Self-cleaning and corrosion-free plug pins made from high-quality materials ensure optimum electrical contact.
Features- Degree of protection IP66, extreme temperature range of –50 to +55 °C
- No impact of torsional forces from the cable on the seal
- Wear-free contacts even in aggressive atmosphere
1 - 9 of 9 Part Numbers
150609
Degree of protection IP66, extreme temperature range of –50 to +55 °C
No impact of torsional forces from the cable on the seal
Wear-free contacts even in aggressive atmosphere
Ambient Conditions
- Ambient temperature - -30 °C ... +55 °C
- Ambient temperature °F - -58 - 131 °F
- Ambient temperature max. - +55 °C
- Ambient temperature min. - -30 °C
Components
- Cable diameter - 8.00 - 18.00 mm
Electrical Data
- Auxiliary contacts available - No
- Frequency range - 50 - 60 Hz
- N-pole present - Yes
- Optional auxiliary contacts - No
- PE-pole present - Yes
- Rated operational current - 0.000 - 20.000 A
- Rated operational current - 20.000 A
- Rated operational voltage AC - 0.00 - 480.00 V
- Rated operational voltage AC - 480.00 V
- Rated operational voltage AC 2 - 0.00 - 277.00 V
- Type of voltage - Low voltage
Explosion Protection
- Ambient temperature °C - -30 - 55 °C
- Application range (zones) - 1, 2, 21, 22
- ATEX dust certificate - PTB 03 ATEX 1227
- ATEX gas certificate - PTB 03 ATEX 1227
- Certificates - ATEX (PTB), Brazil (ULB), Canada (CSA), IECEx (PTB), USA (FM)
- Dust explosion protection ATEX - II 2 D Ex tb IIIC T80 °C Db
- Dust explosion protection IECEx - Ex tb IIIC T80 °C Db
- Gas explosion protection ATEX - II 2 G Ex db eb IIC T6 Gb
- Gas explosion protection IECEx - Ex db eb IIC T6 Gb
- IECEX dust certificate - IECEx PTB 05.0023
- IECEX gas certificate - IECEx PTB 05.0023
- Languages of the documentation - English, German
- NEC 500 zones - Class I, Div. 2,
- NEC 505 gas Ex-type - AEx
- NEC 505 zones - Class I, Zone 1 & 2,
General
- Functional Description - R. STAHL Series 8570/22 SolConeX plugs for Zone 1/21 are silicone-free 3-, 4- or 5-pole 16 A plugs. The floating pins allow them to be inserted and removed quickly and easily. The pivoting strain relief makes it easier to install the cable. Self-cleaning and corrosion-free plug pins made from high-quality materials ensure optimum electrical contact.
- Highlights - Degree of protection IP66, extreme temperature range of –50 to +55 °C No impact of torsional forces from the cable on the seal Wear-free contacts even in aggressive atmosphere
- Product Description - Plug
- Product Type - 8570/22-507
- Title Product Variant Technical Data - 8570/22-507 PL 480Y/277 V, 50/60Hz
Mechanical Data
- Coding (clock hour position) - 7
- Colour code - red
- Connection terminals finely-stranded max. - 4.00 mm²
- Connection terminals finely-stranded max. - 4,00 mm2
- Connection terminals min. - 1.50 mm²
- Connection terminals USA max. - 12 AWG
- Connection terminals USA min. - 16 AWG
- Degree of protection (IP) - IP66
- Detailed number of poles - 5 P (3 P + N + PE)
- Enclosure material - Polyamide
- Length - 176.000 mm
- Series - SolConeX
- Type of connection cable - Finely stranded
- Weight - 0.300 kg
150613
Degree of protection IP66, extreme temperature range of –50 to +55 °C
No impact of torsional forces from the cable on the seal
Wear-free contacts even in aggressive atmosphere
Ambient Conditions
- Ambient temperature - -30 °C ... +55 °C
- Ambient temperature °F - -58 - 131 °F
- Ambient temperature max. - +55 °C
- Ambient temperature min. - -30 °C
Components
- Cable diameter - 8.00 - 18.00 mm
Electrical Data
- Auxiliary contacts available - No
- Frequency range - 50 - 60 Hz
- N-pole present - Yes
- Optional auxiliary contacts - No
- PE-pole present - Yes
- Rated operational current - 0.000 - 20.000 A
- Rated operational current - 20.000 A
- Rated operational voltage AC - 0.00 - 208.00 V
- Rated operational voltage AC - 208.00 V
- Rated operational voltage AC 2 - 0.00 - 120.00 V
- Type of voltage - Low voltage
Explosion Protection
- Ambient temperature °C - -30 - 55 °C
- Application range (zones) - 1, 2, 21, 22
- ATEX dust certificate - PTB 03 ATEX 1227
- ATEX gas certificate - PTB 03 ATEX 1227
- Certificates - ATEX (PTB), Brazil (ULB), Canada (CSA), IECEx (PTB), USA (FM)
- Dust explosion protection ATEX - II 2 D Ex tb IIIC T80 °C Db
- Dust explosion protection IECEx - Ex tb IIIC T80 °C Db
- Gas explosion protection ATEX - II 2 G Ex db eb IIC T6 Gb
- Gas explosion protection IECEx - Ex db eb IIC T6 Gb
- IECEX dust certificate - IECEx PTB 05.0023
- IECEX gas certificate - IECEx PTB 05.0023
- Languages of the documentation - English, German
- NEC 500 zones - Class I, Div. 2,
- NEC 505 gas Ex-type - AEx
- NEC 505 zones - Class I, Zone 1 & 2,
General
- Functional Description - R. STAHL Series 8570/22 SolConeX plugs for Zone 1/21 are silicone-free 3-, 4- or 5-pole 16 A plugs. The floating pins allow them to be inserted and removed quickly and easily. The pivoting strain relief makes it easier to install the cable. Self-cleaning and corrosion-free plug pins made from high-quality materials ensure optimum electrical contact.
- Highlights - Degree of protection IP66, extreme temperature range of –50 to +55 °C No impact of torsional forces from the cable on the seal Wear-free contacts even in aggressive atmosphere
- Product Description - Plug
- Product Type - 8570/22-509
- Title Product Variant Technical Data - 8570/22-509 PL 208Y/120 V, 50/60Hz
Mechanical Data
- Coding (clock hour position) - 9
- Colour code - blue
- Connection terminals finely-stranded max. - 4.00 mm²
- Connection terminals finely-stranded max. - 4,00 mm2
- Connection terminals min. - 1.50 mm²
- Connection terminals USA max. - 12 AWG
- Connection terminals USA min. - 16 AWG
- Degree of protection (IP) - IP66
- Detailed number of poles - 5 P (3 P + N + PE)
- Enclosure material - Polyamide
- Length - 176.000 mm
- Series - SolConeX
- Type of connection cable - Finely stranded
- Weight - 0.300 kg
150616
Degree of protection IP66, extreme temperature range of –50 to +55 °C
No impact of torsional forces from the cable on the seal
Wear-free contacts even in aggressive atmosphere
Ambient Conditions
- Ambient temperature - -30 °C ... +55 °C
- Ambient temperature °F - -58 - 131 °F
- Ambient temperature max. - +55 °C
- Ambient temperature min. - -30 °C
Components
- Cable diameter - 8.00 - 18.00 mm
Electrical Data
- Auxiliary contacts available - No
- Frequency range - 50 - 60 Hz
- N-pole present - Yes
- Optional auxiliary contacts - No
- PE-pole present - Yes
- Rated operational current - 20.000 A
- Rated operational current - 0.000 - 20.000 A
- Rated operational voltage AC - 0.00 - 600.00 V
- Rated operational voltage AC - 600.00 V
- Rated operational voltage AC 2 - 0.00 - 347.00 V
- Type of voltage - Low voltage
Explosion Protection
- Ambient temperature °C - -30 - 55 °C
- Application range (zones) - 1, 2, 21, 22
- ATEX dust certificate - PTB 03 ATEX 1227
- ATEX gas certificate - PTB 03 ATEX 1227
- Certificates - ATEX (PTB), Brazil (ULB), Canada (CSA), IECEx (PTB), USA (FM)
- Dust explosion protection ATEX - II 2 D Ex tb IIIC T80 °C Db
- Dust explosion protection IECEx - Ex tb IIIC T80 °C Db
- Gas explosion protection ATEX - II 2 G Ex db eb IIC T6 Gb
- Gas explosion protection IECEx - Ex db eb IIC T6 Gb
- IECEX dust certificate - IECEx PTB 05.0023
- IECEX gas certificate - IECEx PTB 05.0023
- Languages of the documentation - English, German
- NEC 500 zones - Class I, Div. 2,
- NEC 505 gas Ex-type - AEx
- NEC 505 zones - Class I, Zone 1 & 2,
General
- Functional Description - R. STAHL Series 8570/22 SolConeX plugs for Zone 1/21 are silicone-free 3-, 4- or 5-pole 16 A plugs. The floating pins allow them to be inserted and removed quickly and easily. The pivoting strain relief makes it easier to install the cable. Self-cleaning and corrosion-free plug pins made from high-quality materials ensure optimum electrical contact.
- Highlights - Degree of protection IP66, extreme temperature range of –50 to +55 °C No impact of torsional forces from the cable on the seal Wear-free contacts even in aggressive atmosphere
- Product Description - Plug
- Product Type - 8570/22-505
- Title Product Variant Technical Data - 8570/22-505 PL 600Y/347 V, 50/60Hz
Mechanical Data
- Coding (clock hour position) - 5
- Colour code - black
- Connection terminals finely-stranded max. - 4.00 mm²
- Connection terminals finely-stranded max. - 4,00 mm2
- Connection terminals min. - 1.50 mm²
- Connection terminals USA max. - 12 AWG
- Connection terminals USA min. - 16 AWG
- Degree of protection (IP) - IP66
- Detailed number of poles - 5 P (3 P + N + PE)
- Enclosure material - Polyamide
- Length - 176.000 mm
- Series - SolConeX
- Type of connection cable - Finely stranded
- Weight - 0.300 kg
150620
Degree of protection IP66, extreme temperature range of –50 to +55 °C
No impact of torsional forces from the cable on the seal
Wear-free contacts even in aggressive atmosphere
Ambient Conditions
- Ambient temperature - -30 °C ... +55 °C
- Ambient temperature °F - -58 - 131 °F
- Ambient temperature max. - +55 °C
- Ambient temperature min. - -30 °C
Components
- Cable diameter - 8.00 - 18.00 mm
Electrical Data
- Auxiliary contacts available - No
- Frequency range - 50 - 60 Hz
- N-pole present - No
- Optional auxiliary contacts - No
- PE-pole present - Yes
- Rated operational current - 0.000 - 20.000 A
- Rated operational current - 20.000 A
- Rated operational voltage AC - 0.00 - 480.00 V
- Rated operational voltage AC - 480.00 V
- Type of voltage - Low voltage
Explosion Protection
- Ambient temperature °C - -30 - 55 °C
- Application range (zones) - 1, 2, 21, 22
- ATEX dust certificate - PTB 03 ATEX 1227
- ATEX gas certificate - PTB 03 ATEX 1227
- Certificates - ATEX (PTB), Brazil (ULB), Canada (CSA), IECEx (PTB), USA (FM)
- Dust explosion protection ATEX - II 2 D Ex tb IIIC T80 °C Db
- Dust explosion protection IECEx - Ex tb IIIC T80 °C Db
- Gas explosion protection ATEX - II 2 G Ex db eb IIC T6 Gb
- Gas explosion protection IECEx - Ex db eb IIC T6 Gb
- IECEX dust certificate - IECEx PTB 05.0023
- IECEX gas certificate - IECEx PTB 05.0023
- Languages of the documentation - English, German
- NEC 500 zones - Class I, Div. 2,
- NEC 505 gas Ex-type - AEx
- NEC 505 zones - Class I, Zone 1 & 2,
General
- Functional Description - R. STAHL Series 8570/22 SolConeX plugs for Zone 1/21 are silicone-free 3-, 4- or 5-pole 16 A plugs. The floating pins allow them to be inserted and removed quickly and easily. The pivoting strain relief makes it easier to install the cable. Self-cleaning and corrosion-free plug pins made from high-quality materials ensure optimum electrical contact.
- Highlights - Degree of protection IP66, extreme temperature range of –50 to +55 °C No impact of torsional forces from the cable on the seal Wear-free contacts even in aggressive atmosphere
- Product Description - Plug
- Product Type - 8570/22-407
- Title Product Variant Technical Data - 8570/22-407 PL 480V, 50/60Hz
Mechanical Data
- Coding (clock hour position) - 7
- Colour code - red
- Connection terminals finely-stranded max. - 4,00 mm2
- Connection terminals finely-stranded max. - 4.00 mm²
- Connection terminals min. - 1.50 mm²
- Connection terminals USA max. - 12 AWG
- Connection terminals USA min. - 16 AWG
- Degree of protection (IP) - IP66
- Detailed number of poles - 4 P (3 P + PE)
- Enclosure material - Polyamide
- Length - 176.000 mm
- Series - SolConeX
- Type of connection cable - Finely stranded
- Weight - 0.300 kg
150624
Degree of protection IP66, extreme temperature range of –50 to +55 °C
No impact of torsional forces from the cable on the seal
Wear-free contacts even in aggressive atmosphere
Ambient Conditions
- Ambient temperature - -30 °C ... +55 °C
- Ambient temperature °F - -58 - 131 °F
- Ambient temperature max. - +55 °C
- Ambient temperature min. - -30 °C
Components
- Cable diameter - 8.00 - 18.00 mm
Electrical Data
- Auxiliary contacts available - No
- Frequency range - 50 - 60 Hz
- N-pole present - No
- Optional auxiliary contacts - No
- PE-pole present - Yes
- Rated operational current - 20.000 A
- Rated operational current - 0.000 - 20.000 A
- Rated operational voltage AC - 0.00 - 250.00 V
- Rated operational voltage AC - 250.00 V
- Type of voltage - Low voltage
Explosion Protection
- Ambient temperature °C - -30 - 55 °C
- Application range (zones) - 1, 2, 21, 22
- ATEX dust certificate - PTB 03 ATEX 1227
- ATEX gas certificate - PTB 03 ATEX 1227
- Certificates - ATEX (PTB), Brazil (ULB), Canada (CSA), IECEx (PTB), USA (FM)
- Dust explosion protection ATEX - II 2 D Ex tb IIIC T80 °C Db
- Dust explosion protection IECEx - Ex tb IIIC T80 °C Db
- Gas explosion protection ATEX - II 2 G Ex db eb IIC T6 Gb
- Gas explosion protection IECEx - Ex db eb IIC T6 Gb
- IECEX dust certificate - IECEx PTB 05.0023
- IECEX gas certificate - IECEx PTB 05.0023
- Languages of the documentation - English, German
- NEC 500 zones - Class I, Div. 2,
- NEC 505 gas Ex-type - AEx
- NEC 505 zones - Class I, Zone 1 & 2,
General
- Functional Description - R. STAHL Series 8570/22 SolConeX plugs for Zone 1/21 are silicone-free 3-, 4- or 5-pole 16 A plugs. The floating pins allow them to be inserted and removed quickly and easily. The pivoting strain relief makes it easier to install the cable. Self-cleaning and corrosion-free plug pins made from high-quality materials ensure optimum electrical contact.
- Highlights - Degree of protection IP66, extreme temperature range of –50 to +55 °C No impact of torsional forces from the cable on the seal Wear-free contacts even in aggressive atmosphere
- Product Description - Plug
- Product Type - 8570/22-409
- Title Product Variant Technical Data - 8570/22-409 PL 250V, 50/60Hz
Mechanical Data
- Coding (clock hour position) - 9
- Colour code - blue
- Connection terminals finely-stranded max. - 4.00 mm²
- Connection terminals finely-stranded max. - 4,00 mm2
- Connection terminals min. - 1.50 mm²
- Connection terminals USA max. - 12 AWG
- Connection terminals USA min. - 16 AWG
- Degree of protection (IP) - IP66
- Detailed number of poles - 4 P (3 P + PE)
- Enclosure material - Polyamide
- Length - 176.000 mm
- Series - SolConeX
- Type of connection cable - Finely stranded
- Weight - 0.300 kg
150627
Degree of protection IP66, extreme temperature range of –50 to +55 °C
No impact of torsional forces from the cable on the seal
Wear-free contacts even in aggressive atmosphere
Ambient Conditions
- Ambient temperature - -30 °C ... +55 °C
- Ambient temperature °F - -58 - 131 °F
- Ambient temperature max. - +55 °C
- Ambient temperature min. - -30 °C
Components
- Cable diameter - 8.00 - 18.00 mm
Electrical Data
- Auxiliary contacts available - No
- Frequency range - 50 - 60 Hz
- N-pole present - No
- Optional auxiliary contacts - No
- PE-pole present - Yes
- Rated operational current - 0.000 - 20.000 A
- Rated operational current - 20.000 A
- Rated operational voltage AC - 0.00 - 600.00 V
- Rated operational voltage AC - 600.00 V
- Type of voltage - Low voltage
Explosion Protection
- Ambient temperature °C - -30 - 55 °C
- Application range (zones) - 1, 2, 21, 22
- ATEX dust certificate - PTB 03 ATEX 1227
- ATEX gas certificate - PTB 03 ATEX 1227
- Certificates - ATEX (PTB), Brazil (ULB), Canada (CSA), IECEx (PTB), USA (FM)
- Dust explosion protection ATEX - II 2 D Ex tb IIIC T80 °C Db
- Dust explosion protection IECEx - Ex tb IIIC T80 °C Db
- Gas explosion protection ATEX - II 2 G Ex db eb IIC T6 Gb
- Gas explosion protection IECEx - Ex db eb IIC T6 Gb
- IECEX dust certificate - IECEx PTB 05.0023
- IECEX gas certificate - IECEx PTB 05.0023
- Languages of the documentation - English, German
- NEC 500 zones - Class I, Div. 2,
- NEC 505 gas Ex-type - AEx
- NEC 505 zones - Class I, Zone 1 & 2,
General
- Functional Description - R. STAHL Series 8570/22 SolConeX plugs for Zone 1/21 are silicone-free 3-, 4- or 5-pole 16 A plugs. The floating pins allow them to be inserted and removed quickly and easily. The pivoting strain relief makes it easier to install the cable. Self-cleaning and corrosion-free plug pins made from high-quality materials ensure optimum electrical contact.
- Highlights - Degree of protection IP66, extreme temperature range of –50 to +55 °C No impact of torsional forces from the cable on the seal Wear-free contacts even in aggressive atmosphere
- Product Description - Plug
- Product Type - 8570/22-405
- Title Product Variant Technical Data - 8570/22-405 PL 600V, 50/60Hz
Mechanical Data
- Coding (clock hour position) - 5
- Colour code - black
- Connection terminals finely-stranded max. - 4,00 mm2
- Connection terminals finely-stranded max. - 4.00 mm²
- Connection terminals min. - 1.50 mm²
- Connection terminals USA max. - 12 AWG
- Connection terminals USA min. - 16 AWG
- Degree of protection (IP) - IP66
- Detailed number of poles - 4 P (3 P + PE)
- Enclosure material - Polyamide
- Length - 176.000 mm
- Series - SolConeX
- Type of connection cable - Finely stranded
- Weight - 0.300 kg
150635
Degree of protection IP66, extreme temperature range of –50 to +55 °C
No impact of torsional forces from the cable on the seal
Wear-free contacts even in aggressive atmosphere
Ambient Conditions
- Ambient temperature - -30 °C ... +55 °C
- Ambient temperature °F - -58 - 131 °F
- Ambient temperature max. - +55 °C
- Ambient temperature min. - -30 °C
Components
- Cable diameter - 8.00 - 18.00 mm
Electrical Data
- Auxiliary contacts available - No
- Frequency range - 50 - 60 Hz
- N-pole present - No
- Optional auxiliary contacts - No
- PE-pole present - Yes
- Rated operational current - 0.000 - 20.000 A
- Rated operational current - 20.000 A
- Rated operational voltage AC - 480.00 V
- Rated operational voltage AC - 0.00 - 480.00 V
- Type of voltage - Low voltage
Explosion Protection
- Ambient temperature °C - -30 - 55 °C
- Application range (zones) - 1, 2, 21, 22
- ATEX dust certificate - PTB 03 ATEX 1227
- ATEX gas certificate - PTB 03 ATEX 1227
- Certificates - ATEX (PTB), Brazil (ULB), Canada (CSA), IECEx (PTB), USA (FM)
- Dust explosion protection ATEX - II 2 D Ex tb IIIC T80 °C Db
- Dust explosion protection IECEx - Ex tb IIIC T80 °C Db
- Gas explosion protection ATEX - II 2 G Ex db eb IIC T6 Gb
- Gas explosion protection IECEx - Ex db eb IIC T6 Gb
- IECEX dust certificate - IECEx PTB 05.0023
- IECEX gas certificate - IECEx PTB 05.0023
- Languages of the documentation - English, German
- NEC 500 zones - Class I, Div. 2,
- NEC 505 gas Ex-type - AEx
- NEC 505 zones - Class I, Zone 1 & 2,
General
- Functional Description - R. STAHL Series 8570/22 SolConeX plugs for Zone 1/21 are silicone-free 3-, 4- or 5-pole 16 A plugs. The floating pins allow them to be inserted and removed quickly and easily. The pivoting strain relief makes it easier to install the cable. Self-cleaning and corrosion-free plug pins made from high-quality materials ensure optimum electrical contact.
- Highlights - Degree of protection IP66, extreme temperature range of –50 to +55 °C No impact of torsional forces from the cable on the seal Wear-free contacts even in aggressive atmosphere
- Product Description - Plug
- Product Type - 8570/22-307
- Title Product Variant Technical Data - 8570/22-307 PL 480V, 50/60Hz
Mechanical Data
- Coding (clock hour position) - 7
- Colour code - red
- Connection terminals finely-stranded max. - 4.00 mm²
- Connection terminals finely-stranded max. - 4,00 mm2
- Connection terminals min. - 1.50 mm²
- Connection terminals USA max. - 12 AWG
- Connection terminals USA min. - 16 AWG
- Degree of protection (IP) - IP66
- Detailed number of poles - 3 P (2 P + PE)
- Enclosure material - Polyamide
- Length - 176.000 mm
- Series - SolConeX
- Type of connection cable - Finely stranded
- Weight - 0.300 kg
150639
Degree of protection IP66, extreme temperature range of –50 to +55 °C
No impact of torsional forces from the cable on the seal
Wear-free contacts even in aggressive atmosphere
Ambient Conditions
- Ambient temperature - -30 °C ... +55 °C
- Ambient temperature °F - -58 - 131 °F
- Ambient temperature max. - +55 °C
- Ambient temperature min. - -30 °C
Components
- Cable diameter - 8.00 - 18.00 mm
Electrical Data
- Auxiliary contacts available - No
- Frequency range - 50 - 60 Hz
- N-pole present - No
- Optional auxiliary contacts - No
- PE-pole present - Yes
- Rated operational current - 20.000 A
- Rated operational current - 0.000 - 20.000 A
- Rated operational voltage AC - 0.00 - 125.00 V
- Rated operational voltage AC - 125.00 V
- Type of voltage - Low voltage
Explosion Protection
- Ambient temperature °C - -30 - 55 °C
- Application range (zones) - 1, 2, 21, 22
- ATEX dust certificate - PTB 03 ATEX 1227
- ATEX gas certificate - PTB 03 ATEX 1227
- Certificates - ATEX (PTB), Brazil (ULB), Canada (CSA), IECEx (PTB), USA (FM)
- Dust explosion protection ATEX - II 2 D Ex tb IIIC T80 °C Db
- Dust explosion protection IECEx - Ex tb IIIC T80 °C Db
- Gas explosion protection ATEX - II 2 G Ex db eb IIC T6 Gb
- Gas explosion protection IECEx - Ex db eb IIC T6 Gb
- IECEX dust certificate - IECEx PTB 05.0023
- IECEX gas certificate - IECEx PTB 05.0023
- Languages of the documentation - English, German
- NEC 500 zones - Class I, Div. 2,
- NEC 505 gas Ex-type - AEx
- NEC 505 zones - Class I, Zone 1 & 2,
General
- Functional Description - R. STAHL Series 8570/22 SolConeX plugs for Zone 1/21 are silicone-free 3-, 4- or 5-pole 16 A plugs. The floating pins allow them to be inserted and removed quickly and easily. The pivoting strain relief makes it easier to install the cable. Self-cleaning and corrosion-free plug pins made from high-quality materials ensure optimum electrical contact.
- Highlights - Degree of protection IP66, extreme temperature range of –50 to +55 °C No impact of torsional forces from the cable on the seal Wear-free contacts even in aggressive atmosphere
- Product Description - Plug
- Product Type - 8570/22-304
- Title Product Variant Technical Data - 8570/22-304 PL 125V, 50/60Hz
Mechanical Data
- Coding (clock hour position) - 4
- Colour code - yellow
- Connection terminals finely-stranded max. - 4.00 mm²
- Connection terminals finely-stranded max. - 4,00 mm2
- Connection terminals min. - 1.50 mm²
- Connection terminals USA max. - 12 AWG
- Connection terminals USA min. - 16 AWG
- Degree of protection (IP) - IP66
- Detailed number of poles - 3 P (2 P + PE)
- Enclosure material - Polyamide
- Length - 176.000 mm
- Series - SolConeX
- Type of connection cable - Finely stranded
- Weight - 0.300 kg
1 - 9 of 9 Part Numbers