Model 311-M351 Level Transmitter

Brand: GP:50 New York Ltd

Features
  • Output Signal: 4-20 mA
  • Supply Voltage: 9 to 36 Vdc
  • Pressure Range: 0 to 335 meters WC [0 to 500 psi (0 to 34.47 bar, 0 to 3,447 kPa)]
  • Burst Pressure: 5 times FSO or 22,500 psi (1,551 bar, 155,132 kPa)whichever is less
  • Proof Pressure: 2 times FSO or 22,500 psi (1,551 bar, 155,132 kPa) whichever is less
  • Electrical Connections: 1/2" Male NPT conduit with 40' of 3 conductor, 18 AWG Hytrel jacketed cable
  • Process Connection: Oil filled diaphragm
  • Temperature Range:
    • Operating: -40° to 66°C (-40° to 150°F)
    • Compensated: -17.7° to 60°C (0° to 140°F)
    • Effect on Zero/Span: ±2.0% Full Scale Output at 100°F
  • Static Accuracy: Standard: ±0.5% Full Scale Output 
  • Materials of Construction:
    • Housing: 316 Stainless Steel
    • Wetted Parts: 316 Stainless Steel 

1 - 12 of 37 Part Numbers
311-M351 LIFT KIT
311-M351 LIFT KIT
GP:50 Model 311-M351 Submersible Lift Station Sludge Level Transducer Lift Kit
 


  • Pressure Type: Gauge

  • Pressure Range: 0-5 to 0-500 psi

  • Accuracy: ±0.5% RSS

  • Output: 4-20 mA

  • Operating Temperature Range: -40°F to 150°F, -40°C to 66°C
  • 311-M351-PP-2
    311-M351-PP-2
    GP:50 Model 311-M351 Submersible Lift Station Sludge Level Transducer, 15 psi, Gauge

  • Pressure Type: Gauge

  • Pressure Range: 0 - 15 psi

  • Accuracy: ±0.5% RSS

  • Output: 4-20 mA

  • Operating Temperature Range: -40°F to 150°F, -40°C to 66°C
  • 311Z-M351-B-PJ-2/CZTE40
    311Z-M351-B-PJ-2/CZTE40
    GP:50 Model 311-M351 Sludge Level Transducer, Intrinsically Safe, 0.5%, 5 psi, Gauge, Other psi, 40-foot
    311Z-M351-B-PJ-2/PV40
    311Z-M351-B-PJ-2/PV40
    GP:50 Model 311-M351 Sludge Level Transducer, Intrinsically Safe, 0.5%, 5 psi, Gauge, 40-foot
  • Pressure Type: Gauge, Absolute, Sealed, Elevated

  • Pressure Range: 0-5 to 0-500 psi

  • Approval: FM Intrinsically Safe

  • Accuracy: 0.5% - 0.25% FSO RSS

  • Output: 4-20 mA, Intrinisically Safe

  • Operating Temperature Range: -40°F to +150°F, -40°C to +65°C

  • Applications: Raw sewage wetwells, lift station level, process sumps, water tanks and resevoirs

  • Options:

    • Tefzel jacketed cable
    • Standardised output to 0.5% FSO
    • Alternate Outputs and Pressure Units
    • Alternate Calibration signal
    • internal calibration resistor
    • Remote cable mounted zero & span controls
    • Lightening Protection
    311Z-M351-B-PN-2/CT
    311Z-M351-B-PN-2/CT
    GP:50 Model 311-M351 Sludge Level Transducer, Intrinsically Safe, 0.5%, 10 psi, Gauge, Tefzel Jacketed Cable
    • Pressure Type: Gauge
    • Pressure Range: 10 psi
    • Approval: FM Explosions Proof
    • Accuracy: 0.5% RSS
    • Output: 4-20 mA, Intrinisically Safe
    • Operating Temperature Range: -40°F to +150°F, -40°C to +65°C
    • Options:
      • Tefzel jacketed cable
    311Z-M351-B-PN-2/CZPV50
    311Z-M351-B-PN-2/CZPV50
    GP:50 Model 311-M351 Sludge Level Transducer, Intrinsically Safe, 0.5%, 10 psi, Gauge, Other, 50-foot
    311Z-M351-B-PN-2/CZPV60
    311Z-M351-B-PN-2/CZPV60
    GP:50 Model 311-M351 Sludge Level Transducer, Intrinsically Safe, 0.5%, 10 psi, Gauge, Other, 60-foot
    311Z-M351-B-PN-2/CZPV82
    311Z-M351-B-PN-2/CZPV82
    GP:50 Model 311-M351 Sludge Level Transducer, Intrinsically Safe, 0.5%, 10 psi, Gauge, Other, 82-foot
    311Z-M351-B-PN-2/PV40
    311Z-M351-B-PN-2/PV40
    GP:50 Model 311-M351 Sludge Level Transducer, Intrinsically Safe, 0.5%, 10 psi, Gauge, 40-foot
    • Pressure Type: Gauge, Absolute, Sealed, Elevated
    • Pressure Range: 0-10 psi
    • Approval: FM & CSA Intrinsically Safe
    • Accuracy: 0.5%  FSO RSS
    • Output: 4-20 mA, Intrinsically Safe
    • Operating Temperature Range: -40°F to +150°F, -40°C to +65°C
    • Applications: Raw sewage wetwells, lift station level, process sumps, water tanks and resevoirs
    • Options:

    • 40 Feet Poly Vented Jacketed Cable
    • Standardised output to 0.5% FSO
    • Alternate Outputs and Pressure Units
    • Alternate Calibration signal
    • internal calibration resistor
    • Remote cable mounted zero & span controls
    • Lightening Protection
    311Z-M351-B-PN-2/PV60
    311Z-M351-B-PN-2/PV60
    GP:50 Model 311-M351 Sludge Level Transducer, Intrinsically Safe, 0.5%, 10 psi, Gauge, 60-foot
      • Pressure Type: Gauge, Absolute, Sealed, Elevated
      • Pressure Range: 0-10 psi
      • Approval: FM & CSA Intrinsically Safe
      • Accuracy: 0.5% FSO RSS
      • Output: 4-20 mA, Intrinisically Safe
      • Operating Temperature Range: -40°F to +150°F, -40°C to +65°C
      • Applications: Raw sewage wetwells, lift station level, process sumps, water tanks and resevoirs
      • Options:

      • 60 Feet Poly Vented Jacketed Cable
      • Standardised output to 0.5% FSO
      • Alternate Outputs and Pressure Units
      • Alternate Calibration signal
      • internal calibration resistor
      • Remote cable mounted zero & span controls
      • Lightening Protection

    311Z-M351-B-PO-2/CZPV115
    311Z-M351-B-PO-2/CZPV115
    GP:50 Model 311-M351 Sludge Level Transducer, Intrinsically Safe, 0.5%, 25 psi, Gauge, Other, 115-foot
    311Z-M351-B-PP-2
    311Z-M351-B-PP-2
    GP:50 Model 311-M351 Sludge Level Transducer, Intrinsically Safe, 0.5%, 15 psi, Gauge
    • Pressure Type: Gauge
    • Pressure Range: 15 psi
    • Approval: FM Explosions Proof
    • Accuracy: 0.5% RSS
    • Output: 4-20 mA, Intrinisically Safe
    • Operating Temperature Range: -40°F to +150°F, -40°C to +65°C
    1 - 12 of 37 Part Numbers

    Specifications

    Accuracy

    • ± 0.5 % of Full Scale Output

    Burst Pressure

    • 5 times Full Scale Output or 22,500 psi (1,551 bar, 155,132 kPa), whichever is less

    Circuit Protection

    • EMI/RFI Protected

    Compensated Temperature

    • -18° to 60° C (-0° to 140° F)

    Electrical Connectors

    • 1/2” Male NPT Conduit with 40 feet of 3-Conductor, 18 AWG Hytrel Jacketed Cable

    Enclosure, Body Material

    • 316 Stainless Steel

    Excitation Voltage

    • 9-36 Vdc

    Insulation Resistance

    • > 10 megaohms at 50 Vdc & 21° C (70° F)

    Load Impedance

    • 1350 ohms Max.

    Maximum System Pressure

    • psi: 500 (kPa: 3,447, bar: 35)

    Operating Temperature

    • -40° to 66° C (-40° to 150° F)

    Output

    • 4-20 mA

    Pressure Range

    • bar: 0 to 34.47
    • Inches WC: 0 to 1,153 feet
    • Inches WC: 0 to 335 metres
    • kPa: 0 to 3,447
    • psi: 0 to 500

    Proof Pressure

    • 2 times Full Scale Output or 22,500 psi (1,551 bar, 155,132 kPa) whichever is less

    Sensor, Probe Material

    • 316 Stainless Steel

    Span & Zero Effect

    • ± 2.0 % of Full Scale Output at 38° C (100° F)

    Zero Balance

    • ± 1 % of Full Scale Output at 21.1° C (70° F)