Brand: M&C TechGroup Germany GmbHThe M&C oxygen analyzer PMA 20 is a temperature controlled instrument which has been designed for continuous measurements of oxygen concentrations in particle-free and dry sample gas.
The PMA 20 is a reliable and easy-to-operate instrument. It is built into a compact wall mounting housing.
The transducer unit maintains a constant operating temperature of 50° C (122° F) and a flashing LED on the control panel indicates the proper operating temperature of the analyzer.
Features- Thermostated, in a wall mounting housing
- Small space requirement
- Accurate and reliable
- Analog indicator, linear measuring ranges
- Physical measuring principle
- Small stagnant volume, fast response time
- Safety in operation
- Approved according to DIN EN 14181 resp. to 13th and 17th BImSchV and TUV certificate TA-Luft as option
1 - 8 of 8 Part Numbers
02 A 1000
- Power Supply - 230 V 50 Hz
- Indication - Digital metre, 3-1/2-Digit 9 mm High LCD
- Agency Approvals - Without Certificate
02 A 1000 02 A 9000
- Power Supply - 230 V 50 Hz
- Indication - Digital metre, 3-1/2-Digit 18 mm High LCD
- Agency Approvals - Without Certificate
02 A 1000 02 A 9000 02 A 9010
- Power Supply - 230 V 50 Hz
- Indication - Digital metre, 3-1/2-Digit 18 mm High LCD
- Agency Approvals - Approved According to DIN EN 14181 Response to 13th & 17th BImSchV & TA-Luft
02 A 1000 02 A 9010
- Power Supply - 230 V 50 Hz
- Indication - Digital metre, 3-1/2-Digit 9 mm High LCD
- Agency Approvals - Approved According to DIN EN 14181 Response to 13th & 17th BImSchV & TA-Luft
02 A 1000A
- Power Supply - 115 V 60 Hz
- Indication - Digital metre, 3-1/2-Digit 9 mm High LCD
- Agency Approvals - Without Certificate
02 A 1000A 02 A 9000
- Power Supply - 115 V 60 Hz
- Indication - Digital metre, 3-1/2-Digit 18 mm High LCD
- Agency Approvals - Without Certificate
02 A 1000A 02 A 9000 02 A 9010
- Power Supply - 115 V 60 Hz
- Indication - Digital metre, 3-1/2-Digit 18 mm High LCD
- Agency Approvals - Approved According to DIN EN 14181 Response to 13th & 17th BImSchV & TA-Luft
02 A 1000A 02 A 9010
- Power Supply - 115 V 60 Hz
- Indication - Digital metre, 3-1/2-Digit 9 mm High LCD
- Agency Approvals - Approved According to DIN EN 14181 Response to 13th & 17th BImSchV & TA-Luft
1 - 8 of 8 Part Numbers
Specifications
Accuracy
- Accuracy after Calibration (Deviation): Analog = ± 1 % of Span / Digital = ± 0.1 Vol % O₂
Ambient Temperature Range
- -10° to 45° C (14° to 113° F)
- Influence of Ambient Temperature: No Influence 0° to 45° C (32° to 113° F)
Approvals & Certifications
- Electrical Standard: EN 61010
Approvals & Certifications
- Approved According to DIN EN 14181 Response to 13th & 17th BImSchV
- TÜV Certificate TA-Luft as Option
Electrical Connectors
- 1 x PG 11
- 1 x PG 13.5 Cable Gland
- Terminals 2.5 mm²
Enclosure Finish
- Front Colour: Blue
- Front Colour: Grey
Enclosure, Body Material
- Plastic
Environmental Protection
- IP53 EN 60529
Flow Rate
- Flow Rate of Sample Gas: Max.
- Influence of Sample Gas Flow Variation in Gas Flow between 0 to 60 NL/hr Air Will Cause A Difference of 0.1 Vol % O₂
Humidity
- 0 to 90 % Relative Humidity
Indication
- Digital Meter 3-1/2-Digit LCD
- Flashing LED on the Control Panel
- LCD
Materials of Construction
- Materials in Contact with Sample Gas: 316Ti Stainless Steel
- Materials in Contact with Sample Gas: Epoxy Resin
- Materials in Contact with Sample Gas: FPM
- Materials in Contact with Sample Gas: Glass
- Materials in Contact with Sample Gas: Platinum
- Materials in Contact with Sample Gas: Polypropylene
Measuring Range
- 0 to 100 % by Volume O₂, Linear
Mounting
- Wall Mounting
Output
- Output Signals: 0-1 Vdc Non-Isolated, Load > 100 kiloohms, for the Range of 100 Vol %
- Output Signals: 0-20 mA for the Chosen Range, Non-Isolated, Max.
Power Supply
- 115 Vac ± 10 %, 40 to 60 Hz, 26.5 VA
- Internal Power Unit for 230 Vac Standard
Reproducibility
- Deviation: Analog = < 1 % of Span / Digital = ± 0.1 Vol % O₂
Response Time
- Response Time for 90 % of FSD: < 3 seconds at 60 NL/hr Air
Storage Temperature
- -20° to 60° C (-4° to 140° F)
Supply Pressure
- Sample Gas Inlet Pressure - psi: 0.145 to 14.5 (kPa: 1 to 100, bar: 0.01 to 1)
Temperature Range
- Temperature of Sample Gas: -10° to 40° C (14° to 104° F) Dry Gas
Tube Connection
- PP Hose Connectors DN 4/6 for 4 mm I.D. & 6 mm O.D. Tube