LTX01 Continuous Capacitance Level Transmitter

Brand: Intempco Controls, Inc

INTEMPCO LTX01 series 2-wire level transmitters are highly reliable microprocessor based sensors designed to measure tank levels of liquids and certain dry bulk media in metal tanks. 

LTX01 sensors measure the change in capacitance that occurs as the tank level changes and outputs a standard loop-powered 4-20 mA signal. 

After calibration any change in level is recognized and converted to an Analog 4-20 mA signal. 

LTX01 sensors use very high frequency and very low amplitude sensing circuitry to greatly minimize the effects of coating on the sensing probe. 

The LTX01 includes a standard 4-20 mA loop-powered LTX transmitter housed in a rugged enclosure, a 0.50" (12.7 mm) diameter rigid probe for ranges up to 20 feet (6.09 meters) and a mounting fitting. 

A remote mounted DIN Rail transmitter is also available when calibration at enclosure is not practical. 

Probe material is SS316, supplied bare or PFA Teflon jacketed. The LTX01 is designed for tanks which have fitting connections of 1/2" NPT or larger.
Features
  • Continuous loop-powered 4-20 mA operation
  • Microprocessor based
  • Accuracy 1% of span for constant dielectric of material
  • Non-interactive zero and span calibration
  • Calibration accomplished with 4 push buttons
  • Heavy duty industrial design
  • NEMA rated aluminum, stainless, PVC and explosion proof housings available
  • Standard fitting 3/4" NPT, flange and special fittings available

1 - 1 of 1 Part Numbers
LTX01
LTX01
  • Electronic Module - 4-20 mA, 2-Wire Output Module Installed in Enclosure
  • Enclosure - Aluminum Explosion-Proof - 1/2" NPT Conduit
  • Fitting - 3/4" Male NPT
  • Probe Materials - PFA Teflon Clad (For Conductive & Non-Conductive Liquids)
  • Probe Length - 6 Custom Probe Length in Inches
1 - 1 of 1 Part Numbers

Specifications

Accuracy

  • ± 1 % of Full Span (Constant Dielectric)

Ambient Temperature Range

  • -40° to 70° C (-40° to 158° F)

Calibration

  • Via 4 Push-Button Switches Non-interactive Settings

Capacitance

  • 10 to 10,000 PF

Conduit Connection

  • 1/2” NPT Female
  • 3/4” NPT Female
  • PG9 Gland

Damping Adjustment

  • 0 to 30 seconds

Enclosure, Body Material

  • Aluminum Flip-Cover
  • Cast Stainless Steel
  • Machined 316 Stainless Steel
  • PVC

Environmental Protection

  • Explosion-proof Class I, Div. 1, Groups B, C & D, Class II, III, Div. 1, Groups E, F, G
  • IP66
  • IP68
  • NEMA 4
  • NEMA 4X

Flange Material

  • 316 Stainless Steel

Flange Size - 1-1/2” (DN 40)

  • 1-1/2” (DN 40) - 150#

Flange Size - 2-1/2” (DN 65)

  • 2-1/2” (DN 65) - 150#

Flange Size - 2” (DN 50)

  • 2” (DN 50) - 150#

Flange Size - 3” (DN 80)

  • 3” (DN 80) - 150#

Flange Size - 4” (DN 100)

  • 4” (DN 100) - 150#

Flange Size - 5” (DN 125)

  • 5” (DN 125) - 150#

Flange Size - 6” (DN 150)

  • 6” (DN 150) - 150#

Flange Type

  • Raised Face (RF)

Loop Resistance

  • 700 ohms at 24 Vdc, Max.

Mounting

  • Remote Mounted DIN Rail Module

NPT Connection

  • 1” NPT Male
  • 1/2” NPT Male
  • 1-1/2” NPT Male
  • 1-1/4” NPT Male
  • 2” NPT Male
  • 3/4” NPT Male

Output

  • 4-20 mA, Loop Powered

Pressure Range

  • bar: 1 to 34
  • kPa: 100 to 3,400
  • psi: 14.5 to 500

Process Temperature

  • 200° C (392° F) - Max.

Repeatability

  • ± 0.1 % of Span

Sensor, Probe Length

  • Probe: 6 to 240” (152.4 to 6,096 mm)

Sensor, Probe Material

  • Probe: Bare 316 Stainless Steel
  • Probe: PFA Teflon Jacketed

Supply Voltage

  • 12-30 Vdc

  • Water and Water-Based Liquids.
  • Jacketed Probes Required for Conductive Media
  • Organic Acids
  • Oils and Fuels in Some Metallic Tanks
  • Use Bare Probes With Non-Conductive Media
  • Use Cable Probes Where Top Side Access is Limited
  • On-Site Calibration Required
  • Not Recommended Where Material Dielectric Changes
  • Tank must be Conducive or Grounding May be Required or see Other Intempco Level Probes.