Hydrogen Sulfide Sensor TP-700

Brand: Detcon Inc

Model TP-700 is a non-intrusive “Smart” sensor designed to detect and monitor H2 S in air over the range of 0-100 ppm using a proprietary solid state metal oxide semiconductor technology. 

The plug-in, field replaceable detector features over-sized gold-plated connections that help prevent corrosion. 

The TP-700’s rugged framework includes an electro-polished 316 stainless steel housing with fully encapsulated electronics and dual layer surge protection. 

This innovative design virtually eliminates sensor failure due to water ingress, corrosion, vibration, and transient spikes. 

A primary feature of the Model TP-700 is embedded intuitive software that simplifies operator interface by guiding the user through routine calibration, configuration, and fault diagnostic functions using a built-in alpha/numeric display. 

The Model TP-700 is equipped with standard analog 4-20mA, and Modbus™ RS-485 outputs. 

Among its unique features is a wireless option that can be used with Detcon’s SmartWireless® product line. 

Additional integration options include a Remote Alarm Module (RAM) and HART. 

Detcon’s solid state MOS H2 S gas sensor has an infinite shelf life and is supported by a 10-year conditional warranty
Features
  • Failsafe User-Friendly Interface 
  • LED Display (With Antiglare Cover) 
  • Full Text Display Method 
  • Non-intrusive Interface 
  • Auto Zero/Auto Span 
  • Pre-emptive Fault Diagnostics Environmentally Bulletproof 
  • Electropolished 316SS Construction 
  • 100% Epoxy Encapsulated Circuitry 
  • Bulletproof I/O Protection 
  • Water-Proof, Corrosion-Proof, Vibration-Proof Modular and Serviceable 
  • Modular Design 
  • Plug and Play Components 
  • Quick Thread Release (For Sensor Replacement) 
  • Integral Calibration Port

Specifications

Brand

Sensor Type

  • Continuous diffusion/adsorption
  • CHEMFET Solid State Metal Oxide Semiconductor
  • Plug-in field replaceable

Sensor Life

  • 5 to 10 years typical

Measurement Range

  • 0-20 ppm, 0-50 ppm, 0-100 ppm

Accuracy/Repeatability

  • ± 10 % of reading or ± 2 ppm (greater of)

Response/Clearing Time

  • T50 < 30 seconds; T80 < 60 seconds

Outputs

  • Linear 4-20 mA DC
  • RS-485 MODBUS-RTU

Electrical Classification

  • Explosion-proof
  • CSA and US (NRTL)
  • Class I, Div. 1, Groups B, C, D
  • (Tamb = -40° to +75° C)
  • Class I, Zone 1, Group IIB+H2
  • ATEX
  • II 2 G Ex d IIB + H₂ T4 Gb (Tamb = -40° to +70° C)

Ingress Protection

  • NEMA 4X, IP66

Safety Approvals

  • cCSAus
  • Complies with ISA 92.01 Part 1-1998;
  • Performance Requirements for H2 S
  • ATEX
  • CE Marking
  • SIL 2 Certified to IEC 61508

Warranty

  • Plug-in detector - 10 year conditional
  • Transmitter - 2 Years

Operating Temperature Range

  • -40° to +167° F; -40° to +75° C

Storage Temperature Range

  • -31° to +131° F; -35° to +55° C

Operating Humidity Range

  • 5-100 % RH, Non-Condensing

Operating Pressure Range

  • Atmospheric ± 10 %

Dimensions

  • 7" H x 2.2" Dia.; 178 mmH x 65 mm Dia. (sensor assembly only)
  • 11" H x 6.1" W x 3.75" D; 280 mmH x 155 mmW x 96 mmD (with junction box)
  • Mounting holes (J-box) 5.5"; 140 mm center to center

Weight

  • 2 lb, 0.907 kg (sensor only)
  • 3 lb, 2.72 kg (with Aluminum J-Box)
  • 9 lb, 4.08 kg (with Stainless Steel J-Box)

Power Input

  • 11-30 VDC

Power Consumption

  • Normal operation = 68 mA (< 1.7 watt)
  • Maximum = 85 mA (2 watts)

Inrush Current

  • 1.0 A @ 24 V

RFI/EMI Protection

  • Complies with EN 50270

Analog Output

  • Linear 4-20 mA DC (1,000 ohms max loop load @ 24 Vdc)
  • 0 mA - All Fault Diagnostics
  • 2 mA In-Calibration
  • 4-20 mA 0-100 % Full Scale
  • 22 mA Over-range condition

Serial RS-485 Output

  • RS-485 Modbus RTU

Baud Rate

  • 9600 BPS (9600,N,8,1 Half Duplex)

Status Indicators

  • 4-digit LED display with gas concentration Full-script menu prompts for AutoSpan, Set-up Options, and Fault Reporting

Faults Monitored

  • Heater, Loop, Input Voltage, Sensor, Processor, Memory, Calibration

Cable Requirements

  • Power/Analog
  • 3-wire shielded cable
  • Maximum distance is 13,300 ft with 14 AWG
  • Serial Output
  • 2-wire twisted-pair shielded cable specifically for use with RS-485 installations
  • Maximum distance is 4,000 ft to last sensor

I/O Protection

  • Over-voltage, Miswiring, EMI/RFI Immunity

  • Oil and Gas Drilling Rigs 
  • Oil and Gas Production Sites 
  • Refining and Petrochemical 
  • Pulp and Paper Mills 