Yodify Product Library
Instantly add the SP180-H Gas Sample Probe and 50,000+ more product series to your store or catalog  
Book Your Demo and See How
or create your store

The M&C gas sample probe version SP180-H is applicable for continuous gas sampling. The compact design requires only limited space. 

The gas sample probe is equipped with a new protective cover and thus also suitable for outdoor mounting.
Features
  • Sampling of dust loaded process gases
  • Small volume, fast response time
  • Easy mounting and maintenance
  • Self-regulated electrical heating
  • Three EX-Versions: SP180-H-EX T2 to T4 with Ex-certification according to ATEX, suitable for use in Ex zone 2
  • Alarm contact for low temperature
  • With new isolation cover for outdoor mounting
  • Test gas connection according to EN14181 for test gas feeding via filter element available as standard
  • In-Situ probe tube optional

1 - 8 of 8 Part Numbers
02 S 1800
02 S 1800
  • Version - SP180-H
  • Probe - Standard
02 S 1800 02 S 9200
02 S 1800 02 S 9200
  • Version - SP180-H
  • Probe - Insitu Probe Tube Out of 316Ti Stainless Steel Type SP210/SS
02 S 1880
02 S 1880
  • Version - SP180-H-EX2 T4
  • Probe - Standard
02 S 1880 02 S 9200
02 S 1880 02 S 9200
  • Version - SP180-H-EX2 T4
  • Probe - Insitu Probe Tube Out of 316Ti Stainless Steel Type SP210/SS
02 S 1885
02 S 1885
  • Version - SP180-H-EX2 T3
  • Probe - Standard
02 S 1885 02 S 9200
02 S 1885 02 S 9200
  • Version - SP180-H-EX2 T3
  • Probe - Insitu Probe Tube Out of 316Ti Stainless Steel Type SP210/SS
02 S 1890
02 S 1890
  • Version - SP180-H-EX2 T2
  • Probe - Standard
02 S 1890 02 S 9200
02 S 1890 02 S 9200
  • Version - SP180-H-EX2 T2
  • Probe - Insitu Probe Tube Out of 316Ti Stainless Steel Type SP210/SS
1 - 8 of 8 Part Numbers

Specifications

Ambient Temperature Range

  • -25° to 80° C (-13° to 176° F)

Approvals & Certifications

  • Electrical Equipment Standard: EN 60529/EN 61010

Approvals & Certifications

  • ATEX II 3 G Ex Ec Mc IIC T2, T3, T4 Gc, EXAM BVS 16-ATEX-E 039
  • CE

BSP Connection

  • G 3/4”

Consumption

  • Power Consumption: Typically (Fuse) 6 A
  • Power Consumption: Typically 100 VA

Differential Pressure

  • ∆P Pressure Loss with New Filter Element S-2K - psi: 0.058 to 0.217 (kPa: 0.4 to 1.5, Mbar: 4 to 15)

Electrical Connectors

  • 1 x M16 Cable Glands
  • 1 x M20
  • Terminals, Max.

Electrical Contacts

  • Normally Open

Electrical Rating

  • Low Temperature Alarm Contact: 0.5 A (DC) - Version SP180-H-EX2 T2
  • Low Temperature Alarm Contact: 1.5 A at 250 Vac - Version SP180-H-EX2 T2
  • Low Temperature Alarm Contact: 3 A at 250 Vac - Version SP180-H
  • Low Temperature Alarm Contact: 30 A at 30 Vdc - Version SP180-H

Environmental Protection

  • IP54
  • Weatherproof

Flange Material

  • Mounting Flange: 316Ti Stainless Steel

Flange Size - 2-1/2” (DN 65)

  • 2-1/2” (DN 65) - PN 6

Flow Rate

  • ∆P & T90 at Flow of: 100 to 500 NL/hr

Materials of Construction

  • Material of Sample Contacting Parts & Filter Element: Ceramic
  • Material of Sample Contacting Parts: 316 Stainless Steel
  • Material of Sample Contacting Parts: FPM

NPT Connection

  • Connection Sample Outlet: 1/4” NPT Inside with Swagelok Tube Connector Ø 6 x 1 mm (DN 4/6)

Power Supply

  • 110-240 V 50/60 Hz

Pressure Range

  • Sample Pressure - psi a: 5.802 to 87.02 (kPa: 40 to 600, bar: 0.4 to 6)

Response Time

  • T90 Time with Insitu Probe Tube SP210/SS: < 1 to 4 seconds

Sensor, Probe Length

  • Insitu Probe Tube: 3.28 feet (1 metre)

Sensor, Probe Material

  • Insitu Probe Tube: 316 Titanium Stainless Steel

Temperature Range

  • Probe Heating: 90° to 180° C (194° to 356° F) Self-Regulated
Instantly populate your store or catalog 
CREATE YOUR SITE
or book a demo with the Yodify Team
show more