Yodify Product Library
Instantly add the 3051CFC Compact Conditioning Orifice Plate Flow Meter and 50,000+ more product series to your store or catalog
Book Your Demo and See How
or create your store
3051CFC Compact Conditioning Orifice Plate Flow Meter
Brand: RosemountProviding precise flow measurements, the Rosemount 3051CFC Compact Conditioning Orifice Plate Flow Meter is an industry-leading solution designed with a compact conditioning orifice plate.
This conditioning plate has a patented 4-hole design which enables accurate measurement downstream of flow disturbances.
This conditioning orifice plate also reduces pipe straight run, requiring only two pipe diameters (2D) upstream and downstream for installation in tight areas.
Features- Patented 4-hole orifice plate design enables accurate flow measurement near upstream flow disturbances.
- Complete flow assemblies are leak-tested and calibrated to reduce leak points up to 70% and simplify installation
- 10-year stability and 8:1 flow turndown (150:1 rangedown) produce reliable measurements and application flexibility
- Innovative orifice plate requires only 2D upstream and downstream to reduce pipe straight-run requirements
- Local operator interface offers easy-to-use menus and built-in configuration buttons for streamlined commissioning
- Loop Integrity diagnostics detect electrical loop issues for reduced downtime
- SIL 2/3 certified to IEC 61508 (via 3rd party) and prior-use certificate of FMEDA data for safety installations
Specifications
Brand
Accuracy
- ± 1.75 % to ± 2.10 % of Flow Rate at 8: 1 Flow Turndown
Alarm
- Custom Alarm & Saturation Signal Levels
- NAMUR Alarm & Saturation Signal Levels
Ambient Temperature Range
- -40° to 85° C (-40° to 185° F)
Applications
- Marine & Offshore Applications
Approvals & Certifications
- ATEX
- CSA
- FM
- IEC Ex
- INMETRO
- NEPSI
Configuration
- 4-20 mA HART
- FOUNDATION Fieldbus Protocols
- Low-Power, 1-5 Vdc with Digital Signal based on HART Protocol
- PROFIBUS PA Protocol
- Wireless Protocols
Damping Adjustment
- User Configurable from 0 to 60 seconds
Display
- LCD Display
- LCD Display with Local Operator Interface
- None
Drain, Vent Valves & Plug
- 316 Stainless Steel
- Hastelloy C-276
- Monel 400
Electrical Connectors
- 1/2” NPT
- G 1/2”
- M20 x 1.5
Electromagnetic Interference Effect
- Meets All Relevant Requirements of EN 61326 & NAMUR NE-21
Enclosure Finish
- Polyurethane Paint
Enclosure, Body Material
- Cast Stainless Steel
- Low-Copper Aluminum
Environmental Protection
- IP66
- IP67
- IP68
- NEMA 4X / IP66, 67, 68
Fill Material
- Inert Sensor Fill
- Silicone Oil
Flange Material
- 316 Stainless Steel
- Alloy 400 or Monel
- Hastelloy C-276
- Plated Carbon Steel
Humidity
- 0 to 100 % Relative Humidity
Input Power
- 1-5 Vdc HART Low Power: 9-28 Vdc
- 4-20 mA HART: 10.5-42.4 Vdc
- FOUNDATION Fieldbus: 9-32 Vdc
- PROFIBUS: 9-32 Vdc
NACE & NIST
- NACE MR-0175, ISO 15156
O-Ring Material
- Buna-N
- Glass-Filled PTFE
- Graphite-Filled PTFE
Output
- 2.4 GHz DSSS
- 2-Wire 4-20 mA
- 3-Wire 1-5 Vdc
Overpressure & Static Pressure Limits
- psig: 750 to 4,500 (bar: 51.7 to 310.3, kPa: 5,171 to 31,026)
Power Supply Effect
- ± 0.005 % of Calibrated Span Per Volt
Pressure Range
- bar: 0 to 2.4
- Inches WC: 0 to 1,000 (mbar: 0 to 2488)
- kPa: 0 to 249
- psi: 0 to 36.12
Pressure Type
- Differential
Process Temperature
- -40° to 149° C (-40° to 300° F)
Stability
- ± 0.2 % of URL for 10-Years
Storage Temperature
- -46° to 110° C (-50° to 230° F)
Vibration Effect
- > ± 0.1 % of URL
Volumetric Displacement
- > 0.005”³ (0.08 cm³)
Wetted Materials
- 316 Stainless Steel
- Alloy 400 or Monel
- Hastelloy C-276
- Plated Carbon Steel
Documentation
Data Sheets
Product Manuals
- Manual: 405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test Data Book and Flow Handbook pdf 1.0 MB
- Manual: Rosemount 1595 Conditioning Orifice Plate pdf 1.7 MB
- Manual: Wet Gas Flow Measurement with Conditioning Orifice Meter Flow Test Data Book and Flow Handbook pdf 881 KB
- Product Manual - The Rosemount® Annubar® Flowmeter Series pdf 5.9 MB
- Quick Start Guide: Rosemount 1595 Conditioning Orifice Plate pdf 1.2 MB
- Quick Start Guide: Rosemount 3051 Pressure Transmitter and 3051CF Series Flowmeter with 4-20 mA HART Revision 5 and 7 Protocol pdf 3.3 MB
- Quick Start Guide: Rosemount 405 Compact Primary Element pdf 4.4 MB
Certificates & Approvals
- Declaration of Conformity: Rosemount 3051 Pressure Products pdf 155 KB
- Declaration of Conformity: Rosemount Annubar, ProBar, Mass ProBar, ProPlate, Mass ProPlate, 405, 1195, 1495, 1496, 1497 pdf 454 KB
- FMEDA Report: Rosemount 3051 Pressure Transmitter pdf 999 KB
- Product Certificate: Enhanced Rosemount 3051 pdf 424 KB
- Product Certificate: IEC 61508 Functional Safety Assessment for Rosemount 3051 Pressure Transmitter pdf 472 KB
- Product Certificate: Primary Elements pdf 253 KB
Drawings & Schematics
- Type 1 Drawing: Rosemount 1595 ANSI Paddle Style Conditioning 2D PDF pdf 321 KB
- Type 1 Drawing: Rosemount 1595 DIN Paddle Style Conditioning Orifice Plate 2D PDF pdf 324 KB
- Type 1 Drawing: Rosemount 1595 RTJ Style Conditioning Orifice Plate 2D PDF pdf 155 KB
- Type 1 Drawing: Rosemount 1595 Universal Style Conditioning Orifice Plate 2D PDF pdf 109 KB
- Type 1 Drawing: Rosemount 405 Compact Orifice Plate / Flowmeter (3051SFC, 3051CFC, 2051CFC, 3095MFC) 2D PDF pdf 4.1 MB