Yodify Product Library
Instantly add the 609 PDM Transformer Partial Discharge Monitor and 50,000+ more product series to your store or catalog  
Book Your Demo and See How
or create your store

609 PDM Transformer Partial Discharge Monitor

Brand: Qualitrol Company

The 609 PDM system is an on-line partial discharge (PD) monitoring system for power transformers, based on industry accepted UHF technology.
Features
  • Accurate and early incipient fault detection ensures reliable operation and reduces supply outages
  • Creates highly accurate reports on asset condition hence reduces maintenance costs
  • Monitors multiple transformers simultaneously resulting in higher return on investment
  • Robust design and excellent interference immunity for measurements under difficult environmental conditions
  • Advanced HMI provisions(intelligent data handling, display and interpretation)
  • Qualitrol Expert PD analysis services
  • Flexible installation and configuration options to meet customer expectations
  • Smart and quick real time alarming / alerting mechanism
  • Remote monitoring and configuration
  • Expandable and field upgradable without reconfiguration

Specifications

Ambient Operating Temperature

  • -45° to 55° C (-49° to 131° F)

Clock

  • 1.6 GHz

Data Storage

  • 16 GB

Dynamic Range

  • -75 to -35 dBm (Logarithmic)

Enclosure Rating

  • IP66

Environmental Test Compliance

  • BS EN 60068-2-2, EN 60068-2-1, EN 60068-2-78

Ethernet Port - External

  • RS-232, RJ45 (10/100 Mbps)
  • RS-485 (Full Duplex & Half-Duplex)

Humidity

  • 5 to 95 % - Non-Condensing

HV Testing

  • Ability to Monitor & Record PD During Testing

Immunity

  • Conforms to Relevant Specifications for Monitoring/Control Equipment in HV Substations: BS EN 55022 (: 2006), EN 61000-3-2 to -3-3, EN 61000-4-2 to -4-6, EN 61000-4-8, EN 61000-4-11, EN 61000-4-18, IEC 60255-5, 61180-1
  • EMI/RFI Immunity

Input (Noise)

  • 1 Separate Noise Channel for External Noise Antenna

Input (UHF)

  • Supports 1 to 6 UHF Channels for UHF Sensor Inputs

Interference Filtering

  • Bandpass Filtering
  • Gating
  • Software Filtering

Local MMI Interface

  • 5.7” Resistive Touch

Memory

  • 2 GB, Upgradable (If Required)

Minimum Size for Installation

  • 20 MB

Mounting

  • UHF Sensor: Internal or External

Noise Sensor

  • Gating Antenna: 100 to 3,000 MHz

Output

  • Three SCADA/SCS Alarms Contacts: PD Warning, PD Alarm, System Fault, Ethernet (IEC 61850), 12 x LED Status Indicators (Bi-Colour)

Protocol

  • Ethernet/Serial, Modbus (Serial), IEC 61850

Reporting

  • Daily, Weekly & Monthly Reports

Sample Rate

  • 15,360 Samples / second Per Channel at 60 Hz

Seismic

  • IEEE C37.98 (Seismic Testing of Relays)

Sensitivity

  • UHF Sensor: < 5 PC

Storage Temperature

  • -25° to 85° C (-13° to 185° F)

Supply Power

  • 70 W

UHF Sensor Bandwidth

  • Wideband 200 to 1,500 MHz

UHF Sensor Output

  • Coaxial Analog Output (N-Typical)

USB

  • One Port to Facilitate Firmware Upgrade, Configuration Upgrade & Manual DownLoad of Data

Vibration Test Compliance

  • BS EN 68-2-6, EN 68-2-27, EN 68-2-29

Voltage Range

  • 90-264 Vac, 47 to 63 Hz
Instantly populate your store or catalog 
CREATE YOUR SITE
or book a demo with the Yodify Team
show more