Yodify Product Library
Instantly add the PSC-SSS-Laser-3M Temperature Sensor and 50,000+ more product series to your store or catalog
Book Your Demo and See How
or create your store
PSC-SSS-Laser-3M Temperature Sensor
Brand: Process Sensors CorporationNon-contact temperature measurement with precise aiming from 50° to 1,800° C (122° to 3,272° F).
Features- Accurate temperature measurements of metals, secondary metal processing and ceramic materials
- Double laser aiming marks real spot location at any distance
- Optical resolution up to 100:1 with selectable focus
- Usable up to 85° C (185° F) ambient temperature without cooling
- Short measuring wave length of 2.3 µm reduces error of temperature readings on surfaces with low or unknown emissivity
- Temperature ranges from 50° to 1,800° C (122° to 3,272° F), measuring spots up from 0.7 mm and response times up from 1 Millisecond
1 - 5 of 5 Part Numbers
PSC-SSS-LASER-3MH
- Spectral Range - 2.3 µm
- Temperature Range - 100° to 600° C (212° to 1,112° F)
PSC-SSS-LASER-3MH1
- Spectral Range - 2.3 µm
- Temperature Range - 150° to 1,000° C (302° to 1,832° F)
PSC-SSS-LASER-3MH2
- Spectral Range - 2.3 µm
- Temperature Range - 200° to 1,500° C (392° to 2,732° F)
PSC-SSS-LASER-3MH3
- Spectral Range - 2.3 µm
- Temperature Range - 250° to 1,800° C (482° to 3,272° F)
PSC-SSS-LASER-3ML
- Spectral Range - 2.3 µm
- Temperature Range - 50° to 400° C (150° to 750° F)
1 - 5 of 5 Part Numbers
Specifications
Accuracy
- ± [0.3 % of Reading + 2° C (3.6° F)]
Ambient Temperature Range
- Electronics: 0° to 85° C (32° to 185° F)
- Sensing Head, 50° C with Laser ON: -20° to 85° C (-4° to 185° F)
Cable Length
- 9.8 to 49.2 (3 to 15 metres)
Communication
- CAN
- Ethernet
- PROFIBUS DP
- RS-232
- RS-485
- USB
Environmental Protection
- IP65
- IP66
- NEMA 4
Humidity
- 10 to 95 % Relative Humidity, Non-Condensing
Load Impedance
- mV: Min. 100 kiloohms
Materials of Construction
- Ceramic
Output
- Alarm: 24 V
- Alarm: 50 mA (Open Collector)
- Analog: 0-10 V
- Analog: 0-20 mA
- Analog: 0-5 V
- Analog: 4-20 mA
Output Impedence
- mA: Max.
- Thermocouple: 20 ohms
Power Supply
- 8-36 Vdc
Range
- Spectral Range: 2.3 µm
Repeatability
- ± [0.1 % of Reading + 1° C (1.8° F)]
Resolution
- 0.1 K
- Optical Resolution:(90 % Energy) 100:1 - 3MH
- Optical Resolution:(90 % Energy) 300:1 - 3MH1-H3
- Optical Resolution:(90 % Energy) 60:1 - 3ML
Response Time
- 1 millisecond
Sensor, Probe Type
- J Thermocouple
- K Thermocouple
Shock
- (IEC 68-2-27), 50 G, 11 milliseconds, any Axis
Size
- Spot Size: 0.028” (0.7 mm)
Storage Temperature
- Sensing Head & Electronics: -40° to 85° C (-40° to 185° F)
Temperature Range
- 50° to 1,800° C (122° to 3,272° F)
Vibration
- (IEC 68-2-6), 3 G at 11 to 200 Hz, any Axis