Yodify Product Library
Instantly add the Master-Touch Series 8000MP-8100MP Flow Meter and 50,000+ more product series to your store or catalog  
Book Your Demo and See How
or create your store

Master-Touch Series 8000MP-8100MP Flow Meter

Brand: Eldridge Products, Inc (EPI)

The Master-Touch Series 8000/8100MP flow meters are for use in hazardous area locations. 

Inline style thermal mass flow meters include a flow section that is usually specified to match the user's process line.

Specifications

Accuracy

  • Accuracy Referenced to 21° C (70° F): ± [1 % of Reading + (0.5 % + 0.02 %/°C of Full Scale)]

Approvals & Certifications

  • ATEX (For use in Hazardous Area Locations, Ta = 0° C to 50° C, IP66, Ex d IIB + H₂ T4 Gb/Ex T IIIC T135° C Db or Ex d IIB + H₂ T3 Gb/Ex T IIIC T200° C Db or Ex d IIB + H₂ T2 Gb/Ex T IIIC T300° C Db, SIRA 12-ATEX-1302)
  • CSA [C-US] (For use in Hazardous Area Locations, Class I, Div. 1, Groups B, C, D, Class II Groups E, F, G Class III: Enclosure Typical 4X, Class I Zone I, AEx d IIB + H₂ IP66, Ex d IIB + H₂ IP66, T2 or T3 or T4 as Marked, Ta = 0° C to 50° C)
  • IECEx (For use in Hazardous Area Locations, T2 or T3 or T4 as Marked, Ta = 0° C to 50° C, Ex d IIB + H₂ T2 to T4 Gb IP66, Ex TD A21 IP66, T135° C to T300° C, IECEx CSA 11.0014)
  • KOSHA (For use in Hazardous Area Locations, Class I Groups B, C, D, Class II Groups E, F, G Class III, Enclosure Typical 4X, Class I Zone I, AEx d IIB=H₂ IP66, Ex d IIB + H₂ T2 to T4 Gb IP66, Ex TD A21 IP66)

Communication

  • Signal Interface: HART
  • Signal Interface: PROFIBUS DP
  • Signal Interface: RS-232
  • Signal Interface: RS-485 Modbus RTU Embedded

Display

  • LCD (Flow Rate, Flow Total, Gas Temperature)

Environmental Protection

  • IP66
  • Typical 4X

Flange Size - 3” (DN 80)

  • Unrated

Flange Size - 4” (DN 100)

  • Unrated

Input

  • Input Power Requirement: 115 Vac at 50/60 Hz
  • Input Power Requirement: 230 Vac at 50/60 Hz
  • Input Power Requirement: 24 Vdc at 250 mA

Length

  • 6 to 14” (152.4 to 355.6 mm)

NACE & NIST

  • NIST

NPT Connection

  • 1” NPT Male
  • 1/2” NPT Male
  • 1/4” NPT Male
  • 1-1/2” NPT Male
  • 1-1/4” NPT Male
  • 2” NPT Male
  • 2-1/2” NPT Male
  • 3/4” NPT Male
  • 3/8” NPT Male

Output

  • Linear Signal Output: 0-5 Vdc (Flow & Temperature)
  • Linear Signal Output: 4-20 mA (Flow & Temperature)

Power Requirement

  • Flow Transmitter Power Requirement: 5 W, Max.
  • RAM Back-Up: Lithium Battery

Pressure Rating

  • psi: 500 (kPa: 3,447, bar: 34.47) - Max.

Repeatability

  • ± 0.2 % of Full Scale

Response Time

  • Sensor: 1 second to 63 % of Final Value

Sensor, Probe Material

  • Sensor: 316 Stainless Steel Sheath
  • Sensor: Hastelloy C Sheath

Sensor, Probe Type

  • Sensor: RTD

Temperature Coefficient

  • Gas Temperature Coefficient (GTC): 0.02 % of Full Scale/°C

Temperature Range

  • Electronics PCB: -40° to 70° C (-40° to 158° F)
  • Environmental: -40° to 60° C (-40° to 140° F)
  • Gas: -40° to 200° C (-40° to 392° F)
  • Standard Temperature & Pressure (STP): 21° C (70° F) & 29.92” Hg (Air .075 lbs/ft²)

Turndown

  • 100:1 at 1,500 SFPM / 7.6 NMPS Min. Full Scale

Wetted Materials

  • 316 Stainless Steel
  • Hastelloy
Instantly populate your store or catalog 
CREATE YOUR SITE
or book a demo with the Yodify Team
show more