Yodify Product Library
Add the MT220 Digital Manometer to your store or catalog  
Book Your Demo and See How
or create your store

The MT220 can measure pressure with outstanding accuracy, high resolution, minimal tempo, and excellent stability. 

It offers a wealth of functions for field calibration, including transmitter output measurement (DCV/DCA functions), 24 Vdc output, percent error readout, measurement data memory, and Ni-Cd battery operation. 

The D/A conversion output makes it simple to output data to a recorder or other equipment. And of course, data output through a GP-IB or RS-232 interface is also possible-including data output during operation on a 12 Vdc power supply or Ni-Cd batteries.
Features
  • High Accuracy: ±0.02% of Reading, with a Maximum Allowable Input of 500 kPa (130 kPa Range Model)
  • Measurement with DCV and DCA
  • 24 Vdc Output
  • Percent Reading
  • Error Reading
  • Measurement Data Memory
  • D/A Conversion Output, Comparator Output, and External Trigger Input (Optional)
  • GP-IB and RS-232 Interfaces
  • 12 Vdc Power Supply
  • Battery Operation (Optional)

Specifications

Accuracy

  • ± (0.01 % of Reading + 0.005 % of Full Scale) at 23° ± 3° C (73.4° ± 5.4° F), Six Months after Calibration - for Model 767357
  • ± (0.01 % of Reading + 2-Digits) at 23° ± 3° C (73.4° ± 5.4° F) 30 Days after Calibration - for DC Voltage & DC Current
  • ± (0.03 % of Reading + 2-Digits) at 23° ± 3° C (73.4° ± 5.4° F) 90 Days after Calibration - for DC Voltage & DC Current
  • ± (0.05 % of Reading + 3-Digits) at 23° ± 3° C (73.4° ± 5.4° F) 6 Months after Calibration - for DC Voltage & DC Current
  • ± (0.07 % of Reading + 3-Digits) at 23° ± 3° C (73.4° ± 5.4° F) 1-Year after Calibration - for DC Voltage & DC Current
  • ± 0.005 % of Full Scale at 23° ± 3° C (73.4° ± 5.4° F), One Year after Calibration - Measurement Accuracy (767353, 767355, 767356, 767357)
  • ± 0.01 % of Full Scale at 23° ± 3° C (73.4° ± 5.4° F), One Year after Calibration - Measurement Accuracy (767351)
  • ± 0.02 % of Reading - High Accuracy
  • ± 0.05 % of Full Scale at 23° ± 3° C (73.4° ± 5.4° F) after Zero Calibration - Output Accuracy Using D/A Conversion Output
  • ± 0.075 % - Pressure/Differential Pressure Transmitters
  • Negative Pressure: ± (0.2 % of Reading + 0.1 % of Full Scale) at 23° ± 3° C (73.4° ± 5.4° F), Six Months after Calibration - for Model 767351, 767353, 767355, 767356
  • Positive Pressure: ± (0.01 % of Reading + 0.005 % of Full Scale) at 23° ± 3° C (73.4° ± 5.4° F), Six Months after Calibration - for Model 767355, 767356
  • Positive Pressure: ± (0.01 % of Reading + 0.015 % of Full Scale) at 23° ± 3° C (73.4° ± 5.4° F), Six Months after Calibration - for Model 767351
  • Positive Pressure: ± (0.01 % of Reading + 3-Digits) for 20 to 130 kPa, ± 5-Digits for 0 to 20 kPa at 23° ± 3° C (73.4° ± 5.4° F), Six Months after Calibration - for Model 767353

Applications

  • Automakers & Their Affiliates
  • Chemical & Petrochemical
  • Electric Home Appliances Manufacturers
  • Electric Power Companies
  • Heavy Electrical Machinery Builders
  • National & Public Research Institutions
  • Nuclear Power Station
  • Oil Refinery Companies
  • Pharmaceutical Manufacturers
  • Precision Instruments Manufacturers
  • Semiconductor & Electronic Components Manufacturers

Approvals & Certifications

  • BS
  • IEEE Standard 488-1978
  • SAA
  • UL
  • VDE

Battery Life

  • 12 Hours Approximately - Recharge Time
  • 6 Hours Approximately in Continuous Operation Mode when Fully Charged for Nickel-Cadmium Batteries

Communication

  • Baud Rate: 1200, 2400, 4800, 9600-bits/sec - Transfer Rate
  • GPIB (IEEE 488-1978)
  • RS-232 Interfaces (Start & Stop Synchronization)

Connection Material

  • Stainless Steel (JIS SUS316) - Input Connector

Consumption

  • 10 VA, Max.
  • 25 VA, Max.
  • 40 VA, Max.
  • 45 VA, Max.
  • 65 VA, Max.

Diaphragm Material

  • Hastelloy C-276

Display

  • 3.5-Digits - for Model 767355
  • 4.5-Digits for Pressure Measurement & Measurement with DCV & DCA Funtions - for Model 767355
  • 5.5-Digits for Pressure Measurement
  • LCD Display (with Backlight)

Electrical Connectors

  • 1/4" NPT Female Threaded - Pressure Input Connection
  • 1/4" VCO - Pressure Input Connection
  • 1/4" BSPT - Pressure Input Connection

Electrical Rating

  • 100-120 Vac at 50/60 Hz
  • 10-15 Vdc
  • 200-240 Vac at 50/60 Hz

Element

  • Diaphragm - Pressure Sensing Element

Flange Material

  • Stainless Steel (JIS SUS316) - Flange of Measurement Chamber

Frequency

  • 47 to 63 Hz - Allowable Supply Frequency

Humidity

  • 20 to 80 % RH, Non-Condensing

Input

  • 100 mA - Max.
  • 30 Vdc - Max.
  • psi: 0.39 Absolute to 435.1 Gauge (kPa: 2.7 to 3,000, bar: 0.027 to 30) - for Model 767355
  • psi: 0.39 Absolute to 652.7 Gauge (kPa: 2.7 to 4,500, bar: 0.027 to 45) - for Model 767356
  • psi: 0.39 Absolute to 72.52 Gauge (kPa: 2.7 to 500, bar: 0.027 to 5) - for Models 767351, 767353
  • psia: 0 to 72.52 (kPa: 0 to 500, bar: 0 to 5) - for Model 767357

Input Impedance

  • 10 MΩ Approximately - for DC Voltage
  • 20 MΩ Approximately - for DC Current

Insulation Resistance

  • Minimum 20 MΩ at 500 Vdc - between AC Power Supply & Casing

Internal Part Material

  • Stainless Steel (JIS SUS316) - Internal Piping

Media

  • Gas
  • Liquids (Non-flammable, Non-explosive, Non-Toxic & Non-Corrosive Fluids)

Mounting Position Effect

  • Span: ± 0.01 % of Full Scale - Right/Left Incline of 30° (767356)
  • Span: ± 0.05 % of Full Scale - Right/Left Incline of 30° (767355)
  • Span: ± 0.2 % of Full Scale - Right/Left Incline of 30° (767353, 767357)
  • Span: ± 2.5 % of Full Scale - Right/Left Incline of 30° (767351)
  • Zero Point: ± 0.01 % of Full Scale - Forward/Backward Incline of 90° (767353, 767355, 767356, 767357)
  • Zero Point: ± 0.1 % of Full Scale - Forward/Backward Incline of 90° (767351)

NACE & NIST

  • NIST

O-Ring Material

  • Fluororubber

Operating Temperature

  • 5° to 40° C (41° to 104° F)

Operating Voltages

  • 1,500 Vac at 50/60 Hz for 1 Minute between AC Power Supply & Casing - Withstanding Voltage

Output

  • 0 to ± 2 V-D/A Conversion Output
  • 0 to ± 5 V-D/A Conversion Output
  • 24 ± 1 Vdc (Fixed)
  • 24 Vdc
  • 30 mA - Max.

Output Noise

  • 120 dB min. (50/60 Hz, Rs = 1 kΩ) - Common Mode Rejection Ratio
  • 60 dB Min. (50/60 Hz) - Normal Mode Rejection Ratio

Power Requirement

  • Nickel-Cadmium Battery

Pressure Range

  • Negative Pressure: psig: -1.45 to 0 (kPa: -10 to 0, bar: -0.1 to 0) - for Model 767351
  • Negative Pressure: psig: -11.6 to 0 (kPa: -80 to 0, bar: -0.8 to 0) - for Model 767353, 767355, 767356
  • Positive Pressure: psig: 0 to 1.45 (kPa: 0 to 10, bar: 0 to 0.1) - for Model 767351
  • Positive Pressure: psig: 0 to 101.5 (kPa: 0 to 700, bar: 0 to 7) - for Model 767355
  • Positive Pressure: psig: 0 to 18.85 (kPa: 0 to 130, bar: 0 to 1.3) - for Model 767353
  • Positive Pressure: psig: 0 to 435.1 (kPa: 0 to 3,000, bar: 0 to 30) - for Model 767356
  • psia: 0 to 18.85 (kPa: 0 to 130, bar: 0 to 1.3) - for Model 767357

Pressure Type

  • Absolute
  • Gauge

Resistance

  • 0.1 ohms, Max.
  • 1 kΩ min. - Load Resistance

Resolution

  • 0.0001 kPa - Model 767351
  • 0.001 kPa - Model 767353 & 767357
  • 0.01 kPa - Model 767355 & 767356
  • 16-bits, where Full Scale is Approximately ± 125 % of Range - Output Resolution

Response Time

  • 2.5 seconds, Max.

Sensor, Probe Material

  • Silicon

Sensor, Probe Type

  • Pressure Sensor

Storage Temperature

  • -20° to 60° C (-4° to 140° F)

Supply Voltage

  • 180-264 Vac
  • 90-132 V

Temperature Effect

  • ± (0.005 % of Full Scale)/°C - D/A Conversion Output
  • ± (0.01 % of Reading + 2-Digits)/10° C (50° F) - for DC Voltage & Current
  • Span & Zero Point: ± 0.001 % of Full Scale/°C - for Models 767353, 767355, 767356, 767357
  • Zero Point: ± 0.0015 % of Full Scale/°C - for Model 767351

Temperature Range

  • 5° to 50° C (41° to 122° F) - Fluid Temperature

Update Time

  • 2 ms Approximately - Output Update Interval
  • 250 ms - Readout Update Interval
  • 5 minutes Approximately - Warm-Up Time

Volumetric Displacement

  • 0.61 in³ (10 cm³) Approximately - Internal Volume

  • Automakers & Their Affiliates
  • Chemical & Petrochemical
  • Electric Home Appliances Manufacturers
  • Electric Power Companies
  • Heavy Electrical Machinery Builders
  • National & Public Research Institutions
  • Nuclear Power Station
  • Oil Refinery Companies
  • Pharmaceutical Manufacturers
  • Precision Instruments Manufacturers
  • Semiconductor & Electronic Components Manufacturers

Instantly populate your store or catalog 
CREATE YOUR SITE
or book a demo with the Yodify Team
show more