Yodify Product Library
Instantly add the OPTISONIC 6300 Ultrasonic Flowmeter and 50,000+ more product series to your store or catalog
Book Your Demo and See How
or create your store
OPTISONIC 6300 Ultrasonic Flowmeter
Brand: KrohneThe OPTISONIC 6300 stands for continuity and long term reliability. Flow measurement can be done anywhere and start-up is immediate.
The new OPTISONIC 6300 clamp-on flowmeter for liquids with its robust industrial construction and regreasing concept provides a revolutionary solution for easy handling. It can be fitted on the outside of piping to measure the flow rate of liquids.
The clamp-on flowmeter is a combination of one up to two OPTISONIC 6000 clamp-on sensor(s) and one UFC 300 ultrasonic signal converter.
The overall functionality of the clamp-on flowmeter is the continuous measurement of actual volume flow, mass flow, flow speed, velocity of sound, gain, SNR and diagnosis value.
Specifications
Brand
Ambient Temperature Range
- Sensor: -40° to 70° C (-40° to 158° F)
- Signal Converter: -40° to 60° C (-40° to 140° F)
Applications
- Broad Range of Refined Hydrocarbons
- Chemical Addition
- Cooling Water Circuits
- Deionized & Demineralized Water
- General Process Control
- Potable Water & Purified Water
- Sanitary Flow Rate Measurements
Approvals & Certifications
- ATEX Ex
- CSA - GP/Class I, Div. 1/2
- EMC Directive: 89/336/EEC, Harmonized Standard: EN 61326-1: 2006
- FM: Class I, Div. 1/2
- LVD Directive: 2006/95/EC, Harmonized Standard: EN 61010: 2001
- NAMUR NE21/04
Approvals & Certifications
- Vibration Resistance: IEC 68-2-64, Shock Resistance: IEC 60068-2-27
Cable Entry
- 1/2” NPT
- 1/2” PF
- M20 x 1.5
Cable Length
- Signal Cable: 15 feet (5 metres)
- Signal Cable: Max.
Cable Material
- Cable Connection: Polysulfone (PSU)
Communication
- HART
Consumption
- Power Consumption: 12 W (DC)
- Power Consumption: 22 VA (AC)
Diagnostics
- Self Diagnostics: Bargraph
- Self Diagnostics: Empty Pipe Detection
- Self Diagnostics: Flowmeter
- Self Diagnostics: Measured Value
- Self Diagnostics: Process
Diameter
- Large: Outer Diameter Must be Smaller Than 169.29” (4,300 mm)
- Small: Outer Diameter Must be at Least 0.79” (20 mm)
Display
- Display Turnable in 90° Steps
- Graphic Display: LCD Display, Backlit White (128 x 64 Pixels, 59 x 31 mm)
Environmental Protection
- IP65
- IP66
- IP67
- NEMA 4
- NEMA 4X
- NEMA 6
Humidity
- 5 to 80 % Relative Humidity
Load Resistance
- ≥ 250 ohms
Materials of Construction
- F Version: 316L Stainless Steel (1.4408)
- Pipe: Asbestos Cement
- Pipe: Ceramic
- Pipe: Metal
- Pipe: Plastic
- W Version: Polyamide-Polycarbonate
Measuring Error
- Maximum
Media
- Liquids
O-Ring Material
- FKM
Operating Temperature
- -40° to 60° C (-40° to 140° F)
Output
- Error Identification for with HART: 3.5-22 mA
- Error Identification for without HART: 0-22 mA
- With & without HART: 10-21.5 mA
- With HART: 4-20 mA
- Without HART: 0-20 mA
Power Supply
- 100-230 Vac (-15 % / 10 %)
- 24 Vac/dc (-15 % / 10 %)
Principle of Operation
- Measuring Principle: Ultrasonic Transit Time
Process Temperature
- Standard Version: -40° to 120° C (-40° to 248° F)
- XT Version: -40° to 200° C (-40° to 392° F)
Pulse Range
- 0.05 to 2,000 milliseconds
Repeatability
- < ± 0.2 %
Sensor, Probe Material
- Sensor: 316L Stainless Steel, 1.4401
- Sensor: Anodised Aluminum
Storage Temperature
- -50° to 70° C (-58° to 158° F)
Time Constant
- 0 to 100 seconds
- Settable in 0.1 second steps
Viscosity
- < 100 cSt